Abstract
Sixty-five patients with suspected pulmonary embolism were studied prospectively with both Kr-81 m and Xe-133 ventilation imaging and Tc-99m MAA perfusion imaging. The krypton images, perfusion scintigrams and chest radiographs were read independently of the xenon images, perfusion scintigrams and chest radiographs by three observers. The studies of 53 patients were interpreted as normal or as indicative of a low or intermediate probability for pulmonary embolism with both gases. One study indicated intermediate probability with Xe-133 due to diffuse, severe xenon retention but low probability with Kr-81 m because of close ventilation-perfusion correspondence. The studies of 9 patients indicated a high probability of embolism with both gases, while those of two additional patients (one with emboli at angiography) indicated a high probability only with Kr-81m. While essential agreement between Xe-133 and Kr-81m ventilation imaging was found in most patients, the significant difference in interpretation in 2 of 11 patients with probable pulmonary embolism suggests that a controlled, prospective trial with pulmonary angiography is warranted before Kr-81m is employed for routine clinical use.
Similar content being viewed by others
References
Alderson PO, Lee H, Summer WR, Motazedi A, Wagner HN (1979) Comparison of Xe-133 washout and single-breath imaging for the detection of ventilation abnormalities. J Nucl Med 20:917–922
Alderson PO, Line BR (1980) Scintigraphic evaluation of regional pulmonary ventilation. Semin Nucl Med 10:218–242
Alderson PO, Rujanavech N, Secker-Walker RH, McKnight RC (1976) The role of 133Xe ventilation studies in the radionuclide detection of pulmonary embolism. Radiology 120:633–640
Biello DR, Mattar AG, McKnight RC, Siegel BA (1979) Ventilation-perfusion studies in suspected pulmonary embolism. Am J Roentgenol 133:1033–1037
Coakley AJ, Bateman NJ, Gaunt JI, Croft DN (1978) A comparison between xenon 133 and krypton 81m in the scintigraphic assessment of pulmonary embolism. In: Lavender JP (ed) Clinical and experimental applications of kryopton 81m. British Institute of Radiology, London, pp 92–95
Fazio F, Jones T (1975) Assessment of regional ventilation by continuous inhalation of radioactive krypton-81m. Br Med J 3:673–676
Fazio F, Lavender JP, Steiner RE (1978) 81mKr ventilation and 99mTc perfusion scans in chest disease: comparison with standard radiographs. Am J Roentgenol 130:421–428
Gal IJ, Gal OS (1958) The ion exchange of uranium and some fission products on titanium and zirconium phosphate. In: Second UN Conference on Peaceful Uses of Atomic Energy, paper 468, Geneva
Goris M, Daspit S (1978) Krypton-81m. In: Guter M (ed) Progress in nuclear medicine, vol 5. Newer radiogases in practice. S. Karger, Basel, pp 69–92
Goris ML, Daspit SG, Walter JP, McRae J, Lamb J (1977) Applications of ventilation lung imaging with 81mKrypton. Radiology 122:399–403
Lavender JP (1978) Krypton 81m ventilation studies in pulmonary embolic disease. In: Lavender JP (ed) Clinical and experimental applications of krypton 81m. British Institute of Radiology, London, pp 83–89
McNeil BJ (1976) A diagnostic strategy using ventilation-perfusion studies in patients suspect for pulmonary embolism. J Nucl Med 17:613–616
Schor RA, Shames DM, Weber PM, Dos Remedios LV (1978) Regional ventilation studies with Kr-81m and Xe-133: A comparative analysis. J Nucl Med 19:348–353
Secker-Walker RH, Siegel BA (1973) The use of nuclear medicine in the diagnosis of lung disease. Radiol Clin North Am 11:215–241
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Miller, T.R., Biello, D.R., Lee, J.I. et al. Ventilation imaging with Kr-81m. Eur J Nucl Med 6, 11–16 (1981). https://doi.org/10.1007/BF00257066
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00257066