Skip to main content

Advertisement

Log in

Evaluation of methods for sizing of colloidal radiopharmaceuticals

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Many different quality control methods have been proposed for characterization of colloidal radiopharmaceuticals, as particle size seems to be of importance for the resulting biological distribution.

Membrane filtration techniques using polycarbonate sheet filters (Nuclepore) is a simple technique. For a number of products good correlation was obtained to particle sizes measured by photon correlation spectroscopy (Nanosizer). For several preparations an increase in particle size with time was observed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Atkins HL, Hauser W, Richards P (1970) Factors affecting distribution of Tc-99m sulfur colloid. Res J Reticuloendothelial Soc 8:176–184

    Google Scholar 

  • Baillie AJ, Stafford S, Whateley TL (1979) Size and stability of liposome suspensions measured by photon correlation spectroscopy. J Pharm Pharmacol 31: 83 P (suppl)

    Google Scholar 

  • Billinghurst MW, Jette D (1979) Colloidal particle-size determination by gel filtration. J Nucl Med 20:133–137

    Google Scholar 

  • Davis MA, Jones AG, Trindade H (1974) A rapid and accurate method for sizing radiocolloids. J Nucl Med 15:923–928

    Google Scholar 

  • Frier M, Vennart W (1976) Physical properties and radioactive colloids used in nuclear medicine. J Pharm Pharmacol 28: 42 P (suppl)

  • Lim TK, Bloomfield VA, Krejcarek G (1979) Size and charge distributions of radiocolloid particles. Int J Appl Rad Isot 30:531–536

    Google Scholar 

  • Persson RBR, Strand SE, Knöös T (1978) Radioanalytical studies of 99mTc-labelled colloids and macromolecules with gel chromatography column scanning technique. J Radional Chem 43:275–286

    Google Scholar 

  • Warbick A, Ege GN, Henkelman RM, Maier G, Lyster DM (1977) An evaluation of radiocolloid sizing techniques. J Nucl Med 18:827–834

    Google Scholar 

  • Whateley TL, Marshall CL, Steele G (1980) Particle size of colloidal radiopharmaceutical liver scanning agents by photon correlation spectroscopy (abstr). Br Pharm Conf Newcastle 1980

  • Zivanovic MA, Meller ST, Trott NG, McCready VR (1980) A clinical comparison of four Tc-labelled radiopharmaceuticals for liver and spleen imaging. In: Höfer R, Bergmann H (eds) Radioaktive Isotope in Klinik und Forschung. H Egermann, Wien, pp 377–383

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pedersen, B., Kristensen, K. Evaluation of methods for sizing of colloidal radiopharmaceuticals. Eur J Nucl Med 6, 521–526 (1981). https://doi.org/10.1007/BF00255885

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00255885

Keywords

Navigation