Summary
Two studies demonstrating the clinical relevance of the labile fraction of haemoglobin A1c are presented. Haemolysates, dialysed at 37 °C against 0.9% NaCl, showed an average decrease of haemoglobin A1c value of 7.0% of total glycosylated haemoglobin, post-dialysis. There was a close correlation between the pre and post-dialysis haemoglobin A1c values (r = 0.9644). In four Type 2 (non-insulin-dependent) diabetic subjects, blood glucose and pre- and post-dialysis haemoglobin A1c values were determined at weekly intervals over an 18-week period, including 6 weeks when oral hypoglycaemic therapy was withheld. During this time, pre and post-dialysis haemoglobin A1c values responded synchronously to changes in blood glucose concentration. The mean coefficient of variation of the pre- and post-dialysis haemoglobin A1c values did not differ significantly over the 18-week period. It is concluded that the routine elimination of the labile fraction of haemoglobin A1c is not necessary to assess control in Type 2 diabetes.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bunn HE, Hanney DN, Gabbay KH, Gallop PM (1975) Further identification of the nature and linkage of the carbohydrate in haemoglobin A1c. Biochem Biophys Res Commun 67: 103–109
Bunn HF, Hanney DN, Kamin S, Gabbay KH, Gallop PM (1976) The biosynthesis of human haemoglobin A1c: slow glycosylation of haemoglobin in vivo. J Clin Invest 57: 1652–1659
Svendson PAa, Christiansen JS, Soegard U, Welinder BS, Nerup J (1980) Rapid changes in chromatographically determined haemoglobin A1c in glucose concentration. Diabetologia 19: 130–136
Boden G, Master RW, Gordon SS, Shuman CR, Owen OE (1980) Monitoring metabolic control in diabetic patients with glycosylated haemoglobin. Ann Intern Med 92: 357–360
Widness JA, Rogler-Brown TL, McCormick KL, Petzold KS, Susa JB, Schwartz HC (1980) Rapid fluctuations in glycohaemoglobin (Haemoglobin A1c) related to acute changes in glucose. J Lab Clin Med 195: 386–393
Cole RA, Soeldner JS, Dunn PJ, Bunn HF (1978) A rapid method for determination of glycosylated haemoglobins using high pressure liquid chromatography. Metabolism 27: 289–301
Dunn PJ, Cole RA, Soeldner JS (1979) Further development and automation of a high pressure liquid chromatography method for the determination of glycosylated haemoglobins. Metabolism 28: 777–779
Bolli G, Compagnucci P, Cartechini MG, De Feo P, Santeusanio F, Brunetti P (1981) Analysis of short-term changes in reversibly and irreversibly glycosylated haemoglobin A1: Relevance to diabetes mellitus. Diabetologia 21: 70–72
Mortensen HB, Svendsen PAa (1981) Determination of haemoglobin A1c by iso-electric focusing. Effect of incubation of erythrocytes and comparison to results obtained by ion-exchange chromatography. Scand J Clin Lab Invest 41: 451–455
Jury DR, Dunn PJ (1982) Glycosylated haemoglobin: an overview of a series of clinical studies. New Zealand Med J 95: 105–109
Shenouda FS, Cockram CS, Baron MD, Tsatsoulis A, Lin Wen Han, Sonksen PH (1982) Importance of short-term changes in glycosylated haemoglobin. Br Med J 284: 1084–1085