Comparison of measurement of glomerular filtration rate by single sample, plasma disappearance slope/intercept and other methods

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract

Various in vitro methods employing radioactive indicators have been presented for the determination of glomerular filtration rate (GFR) including slope/intercept (S/I) and single sample (SS) methods. The S/I technique utilizes the analysis of the slope of a certain segment of the plasma disappearance curve of a suitable radioactive indicator and its intercept on the y axis. The SS method is based on the theoretical volumes of distribution derived from a single plasma concentration at some specific time after intravenous injection of the indicator. Using GFRs estimated from the compartmental analysis of the entire plasma disappearance curve as a reference standard, we have compared the errors of GFR estimation calculated from 12 S/I methods, 3 SS methods and 2 techniques in which original formulae were derived. The errors of the SS method of Tauxe et al. gave the lowest standard error of estimate (Sy·x) of all the methods. The S/I methods gave lowest errors when sampling times were taken between 60 min and 240 min. Almost all the errors observed here were significantly less than those observed using scintillation camera techniques. The SS method seems to be the method of choice for estimation of GFR by single injection techniques. The use of the scintillation camera in conjuction with the SS technique would provide a useful right to left ratio so that individual kidney GFR could be calculated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Boyd E (1935) Growth of the surface area of the human body University of Minnesota Press, p 132

  • Brøchner-Mortenson JA (1972) A single method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 30:271

    Google Scholar 

  • Chantler C, Garnett ES, Parsons V, Veall N (1969) Glomerular filtration rate measurement in man by the single injection method using Cr-EDTA. Clin Sci 37:169–180

    Google Scholar 

  • Chatterton BE (1978) Limitations of the single sample tracer method for determining glomerular filtration rate. Br J Radiol 51:981–985

    Google Scholar 

  • Cohen ML (1974) Radionuclide clearance techniques. Semin Nucl Med 4:23

    Google Scholar 

  • Congiano JL, Generth SM, Renerto L, Berman C (1971) Simplified measurement of glomerular filtration rate. Invest Urol 9:34–38

    Google Scholar 

  • Ditzel J, Vestergaard P, Brinkly V (1972) Glomerular filtration rate determined by 51 Cr-EDTA-complex. Scand J Urol Nephrol 6:166–170

    Google Scholar 

  • Donath A (1971) The simultaneous determination of glomerular filtration rate and effective renal plasma flow by the simple injection clearance technique. Acta Paediatr Scand 60:512–520

    Google Scholar 

  • Dubois D, Dubois EF (1916) A formula to estimate the approximate surface area if height and weight be known. Arch Intern Med 17:863–871

    CAS  Google Scholar 

  • Farmer CD, Tauxe WN, Maher FT, Hunt JC (1967) Measurement of renal function with radioiodinate diatrizoate and o-iodohippurate. Am J Clin Pathol 467:9–16

    Google Scholar 

  • Garnett EJ, Parsons V, Veall N (1967) Measurement of glomerular filtration rate in man using 51 Cr/edetic-acid complex. Lancet 1:818–819

    Google Scholar 

  • Groth T, Tengstrom B (1977) A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 37:39–47

    Google Scholar 

  • Hagstam, Nordenfelt I, Svensson L, Svensson SE (1974) Comparison of methods for determination of glomerular filtration rate in renal disease. Seand J Clin Lab Invest 34:31–36

    Google Scholar 

  • Morgan WD, Birks JL, Sivyer A, Ghose RR (1977) An efficient technique for the simultaneous estimation of GFR and ERPF involving a single injection and two blood samples. J Nucl Med Biol 4:79–83

    Google Scholar 

  • Pritchard WH, Eckstein RW, MacIntyre WJ, Dabay E (1965) Correlation of renal blood flow determined by the single injection of hippuran I-131 with direct measurement of flow. Am Heart J 70:789–796

    Google Scholar 

  • Russell CD, Bischoff PG, Rowell KL, Kontzen F, Lloyd LK, Tauxe WN, Dubovsky EV (1983) Quality control of Tc-99m DTPA for measurement of glomerular filtration: Concise Communication. J Nucl Med 24:722–727

    Google Scholar 

  • Russell CD, Bischoff PG, Kontzen F, Rowell KL, Yester MV, Tauxe WN, Dubovsky EV (1985) Measurement of glomerular filtration rate using technetium-99m DTPA and the gamma camera: A comparison of methods. Eur J Nucl Med 10:519–521

    Google Scholar 

  • Sapirstein LA, Vidt DG, Mandel MJ, Hanusek G (1955) Volumes of distribution and clearance of intravenously injected creatinine in the dog. Am J Physiol 181:330–336

    Google Scholar 

  • Smith HW (1951) The Kidney: Structure and Function in Health and Disease, New York, Oxford University Press

    Google Scholar 

  • Speck B (1968) Determination of renal clearances with radioactive diatrizoate. EDTA and o-I-hippuric acid using the single injection technique. Helv Med Acta 34:486–497

    Google Scholar 

  • Tauxe WN (1986) Determination of glomerular filtration rate by single sample technique following injection of radioiodinated diatrizoate. J Nucl Med 27:45–50

    Google Scholar 

  • Tauxe WN, Maher FT, Taylor VF (1971) Effective renal plasma flow: Estimation from theoretical volumes of distribution of intravenously injected I-131 orthoiodohippurate. Mayo Clin Proc 46:524–531

    Google Scholar 

  • Tauxe WN, Dubovsky EV, Kidd TE (1984) Comparison of measurement of effective renal plasma flow by single plasma sample and plasma disappearance slope/volume methods. Eur J Nucl Med 9:443–445

    Google Scholar 

  • Truninger G, Donath A, Kappeler M (1968) Simplified hippuran clearance. Helv Med Acta 34:116–129

    Google Scholar 

  • Vogeli B, Riedwyl A, Donath A, Oetleker O (1971) Comparison of glomerular filtration rate and effective renal plasma flow obtained by a single injection technique and by means of a standard clearance technique in children. Acta Paediatr Scand 60:528–532

    Google Scholar 

  • Winterborn MH, Beetham R, White RHR (1977) Comparison of plasma disappearance and standard clearance techniques for measuring glomerular filtration rate in children with and without vesicoureteric reflex. Clin Nephrol 7:262–270

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tepe, P.G., Tauxe, W.N., Bagchi, A. et al. Comparison of measurement of glomerular filtration rate by single sample, plasma disappearance slope/intercept and other methods. Eur J Nucl Med 13, 28–31 (1987). https://doi.org/10.1007/BF00252642

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00252642

Key words

Navigation