Abstract
We present a system consisting of a slit lamp stereomicroscope and an adapted video system for the examination of the conjunctival microcirculation. This system permits measurement of the flow of erythrocytes in the vessels of the bulbar conjunctiva. We present values obtained from clinically normal individuals under normal conditions and under conditions of hyperperfusion.
Similar content being viewed by others
References
Asano M, Yoshida K, Tatai K (1964) Blood flow rate in the microcirculation as measured by photoelectric mocroscopy. Bull Inst Public Health 13:201–204
Baker DW, Daigle RE (1977) Noninvasive ultasonic flowmetry. In: Hwang NH, Norman NA (eds) Cardiovascular flow dynamics and measurements. Univ Park Press Baltimore pp 151–189
Baker M, Wayland H (1974) On-line flow rate and velocity profile measurement for blood in microvessels. Microvasc Res 7:131–143
Bollinger A, Butti P, Barras JP, Trachsler H, Siegenthaler W (1974) Red blood cell velocity in nailfolds capillaries of man measured by a television microscopy technique. Microvasc Res 7:61–72
Branemark PI, Jonsson I (1963) Determination of the velocity of corpuscles in blood capillaries. Biorheology 1:143–146
Intaglietta M, Silverman NR, Tompkins WR (1975) Capillary flow velocity measurements in vivo and in situ by television methods. Microvasc Res 10:165–179
Jung F, Körber N, Kiesewetter H, Reim M (1982) Television fluorescein angiography with on-line evaluation of the dilution curves. Int J Microcirc Clin Exp 1:284
Kessler M, Höper J, Schäfer D, Starlinger H (1974) Sauerstofftransport im Gewebe. In: Ahnefeld SW, Burri C, Dick W, Halmagyi M (eds) Mikrozirkulation. Springer-Verlag, Berlin Heidelberg New York
Kiesewetter H, Radtke H, Körber N, Schmid-Schönbein H (1982) Experimental calibration of a two stage prism-grating system for measuring cell velocity. Microvasc Res 23:56–66
Kreyszig E (1979) Statistische Methoden und ihre Anwendungen. Verlag Vandenhoeck und Ruprecht, Göttingen
La Celle PL, Bush RW, Smith BD (1982) Rheological properties of normal and pathological human leukocytes. Int J Microcirc 3:250
Van Leeuwenhoek A (1932) The collected papers of Antoni van Leeuwenhoek, part 1–3. Swets and Zeitlinger, Amsterdam
Monro PAG (1966) Methods for measuring the velocity of moving particles under the microscope. In: Barer R, Cosslett VE (eds) Advances in optical and electron microscopy. Academic Press, London pp 11–40
Riva CE, Feke GT, Eberli B, Benary V (1979) Bi-directional LDV-system for absolut measurement of blood speed in retinal vessels. Appl Opt 3:2301–2306
Sachs L (1975) Statistische Auswertmethoden und ihre Anwendungen. Springer-Verlag, Berlin Heidelberg New York
Schieck F, Brückner A (1930) Kurzes Handbuch der Ophthalmologie. Springer Verlag, Berling Heidelberg New York
Schmid-Schönbein H, Gallasch G, Volger E, Klose HJ (1973) Microrheology and protein chemistry of pathological red cell aggregation (blood sludge) studied in vitro. Biorheology 10:213–227
Slaaf DW, Rood JSPM, Tangelder GJ, Arts T (1979) A bi-directional optical system for on-line red blodd cell velocity measurements. Microvasc Res 17:173
Wayland H, Johnson PC (1967) Erythrocyte velocity measurement in microvessels by a two-slit photometric method. J Appl Physiol 22:333–337
Wells RE, Edgerton H (1967) Blood flow in the microcirculation of the conjunctival vessels of man. Angiology 18:699–704
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Jung, F., Körber, N., Kiesewetter, H. et al. Measuring the microcirculation in the human conjunctiva bulbi under normal and hyperperfusion conditions. Graefe's Arch Clin Exp Ophthalmol 220, 294–297 (1983). https://doi.org/10.1007/BF00231359
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00231359