Abstract
Totally biodegradable, self-reinforced polylactide plates and titanium miniscrews were used for the fixation of horizontal maxillary osteotomies in 32 patients. In two cases the fixation was unstable because of technical problems. In the others the analysis of cephalometric radiographs between immediate and late postoperative showed very similar figures, indicating postoperative stability. There were no complications in the healing due to this biodegradable osteofixation in these patients.
Similar content being viewed by others
References
Bos R, Boering C, Rozema F, Leenslag J, Pennings A, Verwey A (1987) Resorbable poly(l-lactide) plates and screws for the fixation of zygomatic fractures. J Oral Maxillofac Surg 45:751–753.
Bos R, Rozema F, Boering G, Nijenhuis A, Pennings A, Verwey A (1989) Bio-absorbable plates and screws for internal fixation of mandibular fractures. J Oral Maxillofac Surg 18:365–369
Cutright D, Hunsuck E, Beasley J (1971) Fracture reduction using a biodegradable material, polylactic acid. J Oral Surg 29:393–397
Hutmacher D, Claes L, Baehr W (1993) Biodegradable osteosynthesis material for stabilization of midface fractures. I.S.F.R. Symposium on Biodegradable Implants in Fracture fixation. September 4–5, Hong Kong
Illi O, Sailer H, Stauffer U (1989) Resultats preliminaires de l'osteosynthese biodegradable en chirurgie cranio-faciale chez l'enfants. Chir Pédiatr 30:284–287
Majola A, Vainionpää S, Vihtonen K, Vasenius J, Törmälä P, Rokkanen P (1992) Intramedullary fixation of cortical bone osteotomies with self-reinforced polylactic acid rods in rabbits. Int Orthop (SICOT) 16:101–108
Paavolainen P, Karaharju E, Slätis P, Ahonen J, Holmstram T (1978) Effect of rigid plate fixation on structure and mineral content of cortical bone. Clin Orthop Rel Res 136:287–293
Partio E (1992) Immobilisierung und Frühmobilisierung von Malleolarfrakturen nach Osteosynthese mit resorbierbaren Schrauben. Unfallchirurgie 18:304–310
Ricketts R (1957) Planning treatment on the basis of the facial pattern an estimate of its growth. Angle Orthod 27:14–37
Rozema F (1991) Resorbable poly(L-lactide) bone plates and screws. PLLA tests and applications. Dissertation.
Ruuskanen M, Serlo W, Pohjonen T, Törmälä P, Waris T (1993) Anterior thoracoplasty stabilized with resorbable, self-reinforced poly-l-lactide acid plate in the correction of pectus excavatum
Suuronen R (1992) Biodegradable self-reinforced polylactide plates and screws in the fixation of osteotomies in the mandible. Thesis, Helsinki University
Törmälä P (1992) Biodegradable self-reinforced composite materials: manufacturing structure and mechanical properties. Clin Mater 10:29–34
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fuente del Campo, A., Pohjonen, T., Törmälä, P. et al. Fixation of horizontal maxillary osteotomies with biodegradable self-reinforced absorbable polylactide plates: preliminary results. Eur J Plast Surg 19, 7–9 (1996). https://doi.org/10.1007/BF00209782
Issue Date:
DOI: https://doi.org/10.1007/BF00209782