Abstract
Intravenous digital subtraction angiography (IV-DSA) combined with excretory urography (IVU) were utilized to study the renal anatomy of 1000 potential live-kidney donors. In the entire series, 712 donors (71.2%) had bilateral single renal arteries, whereas 255 (25.5%) had unilateral multiple, 26 (2.6%) had bilateral multiple, and 7 (0.7%) had unilateral hypoplastic or absent renal arteries determined by IV-DSA. Major renal abnormalities that might be potentially significant for safe renal donation were detected in 76 donors (7.6%) by combined IV-DSA and IVU studies. In 10% of the potential donors, intraarterial digital subtraction angiography (IA-DSA) was required because of the equivocal results of IV-DSA. Of the 1000 potential donors, 700 underwent nephrectomy and the number of renal arteries at nephrectomy was compared with both IV-DSA and IA-DSA reports. Analysis of data revealed a sensitivity of 96% vs 95%, a specificity of 57% vs 75% and an overall accuracy 93% vs 90% for IV-DSA and IA-DSA, respectively. both IV-DSA and IA-DSA were accurate enough in identification of single renal arteries. However, the accuracy of IA-DSA was better than that of IV-DSA in visualization of double (84% vs 64%) and triple (66% vs 33%) renal arteries. It is concluded that IV-DSA combined with IVU is an effective technique for the evaluation of potential kidney donors. In cases where IV-DSA is equivocal, we recommend confirming IA-DSA.
Similar content being viewed by others
References
Sherwood T, Ruutu M, Chisholm GD. Renal angiography problems in liver kidney donors. Brit J Rad 1978;51:99–105
Flechner SM, Rauschkolb EN, Cohen G, Sandler CM, Ben-Menachem Y, VanBuren CT, Payne WD, Kahan BD. Use of digital subtraction angiography for the evaluation of living related renal transplant donors. Transplantation 1982;33:645–647
Flechner SM, Sandler CM, Houston GK, VanBuren CT, Lorber MI, Kahan BD. 100 living-related kidney donors evaluations using digital subtraction angiography. Transplantation 1985;40:677–678
McElroy J, Novick AC, Streem SB, Steinmuller D, Risius B, Buszta C, Steinhilber D. A prospective analysis of the accuracy and cost-effectiveness of digital subtraction angiography for living-related renal donor evaluation. Transplantation 1986;42:23–27
Crummy AB, Stieghorst MF, Turski PA, Strother CM, Lieberman RP, Sackett JF, Turnipseed WD, Detmer DE, Mistretta CA. Digital subtraction angiography: current status and use of intraarterial injection. Radiology 1982;145:303–307
Kaufman SL, Chang R, Kadir S, Mitchell SE, White RI, Jr. Intraarterial digital subtraction angiography in diagnostic arteriography. Radiology 1984;151:323–327
Cho WH, Jacobs SC, Lawson RK. Digital subtraction angiography for renal donor evaluation. Urology 1987;30:289–291
Kim D, Porter DH, Crivello MS, et al. Renal artery imaging: a prospective comparison of intraarterial digital subtraction angiography with conventional angiography. Angiology 1991;42:345–357
Spring DB, Salvatierra O Jr, Palubinskas AJ, Amend WJC Jr, Vincenti FG, Feduska NJ. Results, significance of angiography in potential kidney donors. Radiology 1979;133:45–47
Anson BJ, Richardson GA, Minear WL. Variations in the number and arrangement of the renal vessels. J Urol 1936;36:211–219
Boijsen E. Angiographic studies of the anatomy of single and multiple renal arteries. Acta Radiol Suppl 1959;183:1–135
Clark RA, Alexander ES. Digital subtraction angiography of the renal arteries: prospective comparison with conventional arteriography. Invest Rad 1983;18:6–10
Hillman BJ, Zukoski CF, Ovitt TW, Ogden DA, Capp MP. Evaluation of potential renal donors and renal allograft recipients: digital video subtraction angiography. Amer J Roentgen 1982;138:921–925
Rabe FE, Smith EJ, Yune HY, Klatte EC, Leapman SB, Filo RS. Limitations of digital subtraction angiography in evaluating potential renal donors. Amer J Roentgen 1983;141:91–93
Sussman SK, Weinerth JL, Braun SD, Saeed M, Illescas FF, Cohan RH, Newman GE, Perlmutt LM, Dunnick NR. Intravenous digital subtraction angiography in the evaluation of potential renal donors. J Urol 1987;138:28–32
Zabbo A, Novick AC. Digital subtraction angiography for noninvasive imaging of the renal artery. Urol Clin North Am 1984;11:409–416
Flechner SM, Sandler CM, Ben-Menachem Y, VanBuren CT, Kahan BD. Evaluation of living-related kidney donors using digital subtraction angiography. Cleve Clin Q 1984;51:339–343
Frick MP, Goldberg ME. Uro-and angiographic findings in a normal population: screening of 151 symptom-free potential transplant donors for renal disease. Amer J Roentgen 1980;134:503–505
Strauser GD, Stables DP, Weil R III. Optimal technique of renal arteriography in living renal transplant donors. Amer J Roentgen 1978;131:813–816
Svetkey LP, Dunnick NR, Coffman TM, Himmelstein SI, Bollinger RR, McCann RL, Wilkinson RH, Braun SD, Newman GF, Cohan RH, Klotman PE. Comparison of intravenous digital subtraction angiography and conventional arteriography in defining renal anatomy. Transplantation 1988;45:56–58
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Shokeir, A.A., El-Diasty, T.A., Nabeeh, A. et al. Digital subtraction angiography in potential live-kidney donors: A study of 1000 cases. Abdom Imaging 19, 461–465 (1994). https://doi.org/10.1007/BF00206941
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00206941