Skip to main content
Log in

Forensische Anwendungen der spektralen Remissionsanalyse menschlicher Haut mit einer beweglichen photometrischen Kugel

Forensic applications of human skin spectral remission analysis employing a movable integrated sphere

  • Originalarbeiten
  • Published:
Zeitschrift für Rechtsmedizin Aims and scope Submit manuscript

Summary

Spectral remission analysis has been known for long in the medical sciences [1,2,3] but has gained practical importance only in the last years due to the existence of modern techniques and components [4,5].

In this paper a method is presented which enlarges the range of applications of spectral remission and transmission analysis for wavelengths between 380 and 1100 nm considerably. This is achieved by a novel conception of the measuring instrumentation, the advantages of which are discussed and compared with the conventional technique.

In detail these advantages are

  1. a)

    employment of a movable instead of a fixed detector (integrated sphere)

  2. b)

    illumination of standard and probe with radiation from a common source

  3. c)

    considerable increase of sensibility due to the use of selective lock-in amplifiers.

As a demonstration of the proposed method results are given for 5 different probes of human skin.

Zusammenfassung

Die spektrale Remissionsanalyse ist in der Medizin seit langem bekannt [1,2,3], gewinnt aber erst in den letzten Jahren dank der modernen Technik immer mehr an praktischer Bedeutung [4,5]. In diesem Aufsatz wird ein Verfahren vorgestellt, das die Anwendungsmöglichkeiten der spektralen Remissionsbzw. Transmissionsanalyse im Bereich von Wellenlängen zwischen 380 und 1100 nm durch eine neuartige Konzeption der Messanordnung erheblich vergrößert. Nach der Erörterung des Standes der Technik werden die Vorteile des neuen Meßverfahrens erläutert.

Diese sind:

  1. a)

    Benutzung eines beweglichen statt eines starren Meßkopfes (photometrische Kugel).

  2. b)

    gleichzeitige Beleuchtung von Probe und Standard mit optischer Strahlung aus einer gemeinsamen Quelle.

  3. c)

    erhebliche Steigerung der Meßempfindlichkeit durch den Einsatz von selektiven Lock-in-Verstärkern.

Es wird über Messungen an fünf verschiedenen Hautregionen einer Leiche berichtet.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Sheard, Ch., Brunstig, L.A.: Color of skin as analyzed by spectrophotometric methods. J. clin. Invest. 7, 559 (1929)

    Google Scholar 

  2. Bode, H.G.: Zur Analyse der menschlichen Hautfarbe. Strahlenther. 43, 565 (1932)

    Google Scholar 

  3. Jacquez, J.A., Kuppenheim, H.F.: Spectral reflectance of human skin in the region 235–1000mμ J. Appl. Physics 7, 522–528 (1955)

    Google Scholar 

  4. Tronnier, H.: Bestimmung der Hautfarbe unter besonderer Berücksichtigung der Erythemund Pigmentmessung. Strahlenther. 121, 392 (1963)

    Google Scholar 

  5. Lins, G., Kutschera, J.: Die farbmetrische Bewertung der Grünfäule der Leichenhaut im Rahmen der programmierten Farbwertintegration. Z. Rechtsmedizin 75, 201–212 (1974)

    Google Scholar 

  6. Lins, G.: Die Remissionsanalyse zur farblichen Charakterisierung der Leichenhaut. Beitr. gerichtl. Med. 24, 162–166 (1968)

    Google Scholar 

  7. Blazek, V.: Ein Verfahren uur optisch eindeutigen Beschreibung von menschlicher Haut. Wissenschaftliche Berichte, BMT Graz, 129–133 (1975)

  8. Blazek, V.: Verhalten der menschlichen Haut gegenüber elektromagnetischer Strahlung im sichtbaren und nahen IR-Bereich Z. Rechtsmedizin 77, 91–103 (1976)

    Google Scholar 

  9. Blazek, V.: Bewegliche photometrische Kugel. Dtsch. Patentanmeldung Nr. P 26 06 675.1

  10. Jacquez, J.A., Kuppenheim, H.F.: Theory of the integrating sphere. J. Opt. Soc. Amer. 15, 416 (1955)

    Google Scholar 

  11. Loof, H.: Farbmessung mit optisch-elektronischen Hilfsmitteln. Elektrische Ausrüstung 13, 5 (1972)

    Google Scholar 

  12. Loof, H.: Untersuchungen über die Genauigkeit des Zeiss-Farbmeßgerätes DMC 25. Sonderdruck aus Tagungsbericht Internationale Farbtagung Color 60, Stockholm. Carl Zeiss Oberkochen/Württbg. 1969

  13. DIN 5033, Farbmessung Bl. 2

  14. DIN 5033, Farbmessung Bl. 7, Seite 3

  15. Wyszecki, G., Stiles, S.: Color Science. New York: J. Wiley & Sons Inc. 1967

    Google Scholar 

  16. Hamstra, R.H., Wendland, P.: Noise and Frequency Response of Silicon Photodiode Operational Amplifier Combination. Applied Optics 7, 1539–1547 (1972)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Blazek, V. Forensische Anwendungen der spektralen Remissionsanalyse menschlicher Haut mit einer beweglichen photometrischen Kugel. Z Rechtsmed 79, 47–62 (1977). https://doi.org/10.1007/BF00204542

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00204542

Key words

Navigation