Skip to main content
Log in

A new coaxial needle system, hepatic artery targeting wire, and biplane fluoroscopy to increase safety and efficacy of TIPS

  • Technical Notes
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

To improve safety and efficacy of the transjugular intrahepatic portosystemic shunt (TIPS) procedure, we introduced a new, thin-needle (21-gauge long PTC needle) puncture technique using biplane fluoroscopy and targeting of a guidewire tip in the right hepatic artery. After puncture of the right portal vein, a 0.016-inch guidewire was inserted into the portal vein, followed by a 4 Fr dilator. The 4 Fr dilator allowed introduction of a 0.035-inch working guidewire. We successfully performed TIPS in seven patients with postnecrotic cirrhosis using this technique and encountered no technical difficulties or complications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Richter GM, Noeldge G, Palmaz JC, Roessle M, Slegerstetter V, Franke M, Gerok W, Wenz W, Farthman E (1990) Transjugular intrahepatic portocaval stent shunt: Preliminary clinical results. Radiology 174:1027–1030

    Google Scholar 

  2. Zemel G, Katzen BT, Becker GJ, Benenati JF, Sallee S (1991) Percutaneous transjugular portosystemic shunt. JAMA 266:390–393

    Google Scholar 

  3. LaBerge JM, Ring EJ, Lake JR, Ferrell LD, Doherty MM, Gordon RL, Roberts JP, Peltzer MY, Ascher NL (1992) Transjugular intrahepatic portosystemic shunt (TIPS): Preliminary results in 25 patients. J Vasc Surg 16:256–267

    Google Scholar 

  4. Rösch J, Barton RE, Keller FS, Uchida B (1992) Transjugular intrahepatic portosystemic shunt. Problems in general surgery 9:502–512

    Google Scholar 

  5. Rösch J, Uchida BT, Barton RE, Keller FS (1993) Coaxial catheter-needle system for transjugular portal vein entrance. JVIR 4:145–147

    Google Scholar 

  6. LaBerge JM, Ring EJ, Gordon RL, Lake JR, Doherty MM, Somberg KA, Roberts JP, Ascher NL (1993) Creation of transjugular intrahepatic portosystemic shunts with Wallstent endoprosthesis: Results in 100 patients. Radiology 187:413–420

    CAS  PubMed  Google Scholar 

  7. Haskal ZJ, Pentecost MJ, Rubin RA (1993) Hepatic arterial injury after transjugular intrahepatic portosystemic shunt placement: Report of two cases. Radiology 188:85–88

    Google Scholar 

  8. LaBerge JM, Ring EJ, Gordon RL (1991) Percutaneous intrahepatic portosystemic shunt created via femoral vein approach. Radiology 181:679–681

    Google Scholar 

  9. Teitelbaum GP, Van Allen RJ, Reed RA, Hanks S, Katz MD (1993) Portal venous branch targeting with a platinum-tipped wire to facilitate transjugular intrahepatic portosystemic shunt (TIPS) procedures. Cardiovasc Intervent Radiol 16:198–200

    CAS  PubMed  Google Scholar 

  10. Harman JT, Reed JD, Kopecky KK, Harris VJ, Haggerty MF, Strembosz AS (1992) Localization of the portal vein for transjugular catheterization: Percutaneous placement of a metallic arker with real-time US guidance. JVIR 3:545–547

    CAS  PubMed  Google Scholar 

  11. Haskal ZJ, Ring EJ, LaBerge JM, Peltzer MY, Radosevich PM, Doherty MM, Gordon RL (1992) Role of parallel transjugular intrahepatic portosystemic shunts in patients with persistent portal hypertension. Radiology 185:813–817

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Matsui, O., Kadoya, M., Yoshikawa, J. et al. A new coaxial needle system, hepatic artery targeting wire, and biplane fluoroscopy to increase safety and efficacy of TIPS. Cardiovasc Intervent Radiol 17, 343–346 (1994). https://doi.org/10.1007/BF00203956

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00203956

Key words

Navigation