Summary
A new method of postmortem electrical stimulation of muscles, measuring the force of the reaction against time, is presented. Preliminary investigations have yielded the following results:
-
The maximum force of reaction in response to a definitive stimulation, measured by a sensitive force transducer, decreases in proportion to the post mortem interval.
-
Using this method, the mechanical reactions of muscles by electrical stimulation can be demonstrated over a much longer postmortem period as these movements are visible. The duration of postmortem reaction of different muscles seems to be much more uniform than was previously assumed. Occasionally, reactions of the M. orbicularis oculi can be seen for the longest time.
-
The basal muscular tonus changes relative to time.
-
The time course of a single force reaction also changes relative to the postmortal interval: the reaction becomes slower.
-
It has been theoretically established that measurement of influencing factors such as temperature and pH in the tested muscle will enable the time of death to be more precisely estimated.
Zusammenfassung
Eine neuartige Methode der postmortalen Elektrostimulation der Muskulatur mit Messung des Kraft-Zeit-Verlaufes der Reaktion wird vorgestellt. Erste orientierende Untersuchungen ergaben:
-
Auf definierte elektrische Reizung nimmt das mit einem empfindlichen Kraftaufnehmer gemessene Kraftmaximum der muskulären Reaktion mit fortschreitender Todeszeit ab.
-
Mit dieser Methodik sind mechanische Reaktionen der Muskulatur auf elektrische Reizung wesentlich länger postmortal nachweisbar als Bewegungen sichtbar sind. Die Dauer der postmortalen Reaktivität verschiedener Muskeln erweist sich als wesentlich homogener als bisher aufgrund sichtbarer Bewegungen angenommen wurde. Am M. orbicularis oculi sind Reaktionen lediglich am längsten sichtbar.
-
Der muskuläre Grundtonus verändert sich mit fortschreitender Todeszeit.
-
Der Kraft-Zeit-Verlauf (also die Kurvenform) der einzelnen Reaktion verändert sich ebenfalls mit fortschreitender Todeszeit: die Reaktion wird zunehmend träger.
-
Es wird theoretisch abgeleitet, daß durch ergänzende Messungen der Einflußfaktoren Temperatur und pH im geprüften Muskel die resultierende Todeszeitbestimmung präzisiert werden kann.
Similar content being viewed by others
Literatur
Bate-Smith EC, Bendall JR (1949) Factors determining the time course of rigor mortis. J Physiol 110:47–65
Beier G, Liebhardt M, Schuck M, Spann W (1977) Totenstarremessung an menschlichen Skelettmuskeln in situ. Z Rechtsmed 79:277–283
Bergfeld P, van der Schoot (1983) The pH-ISFET: Development and application of a new pH-transducer. Abteilung für Bioinformatik Techn Hogeschool Twente, Enschede. Poster-Demonstration im Physiologischen Institut der Universität Münster am 30.11.1983
Forster B (1963) The plastic and elastic deformation of skeletal muscle in rigor mortis. J Forensic Med 10:91–110
Forster B (1963) The contractil deformation of skeletal muscle in rigor mortis. J Forensic Med 10:133–147
Forster B, Ropohl D, Raule P (1977) Eine neue Formel zur Beurteilung der Totenstarre: Die Feststellung des FFR-Index. Z Rechtsmed 80:51–54
Henßge C (1982) Methoden zur Bestimmung der Todeszeit — Leichenabkühlung und Todeszeitbestimmung. Diss B Bereich Medizin Humboldt-Universität Berlin, pp 1–81
Joachim H, Feldman U (1980) Eine quantitative Methode der Todeszeitbestimmung durch Untersuchung der galvanischen Reizschwelle. Z Rechtsmed 85:5–22
Klein A, Klein S (1978) Die Todeszeitbestimmung am menschlichen Auge. Diss B Med Akademie Dresden
Lunkenheimer PP, Lunkenheimer A, Stroh N, Köhler F, Welham K, Graham G, Kirk E, Sonnenblick E, Kröller J (1982) Vergleich klassischer und neuer Zugänge zum intramyokardialen Kraftverteilungsmuster. Zentralbl Veterinärmed A 29:557–601
Prokop O (1975) Supravitale Erscheinungen. In: Prokop O, Göhler W (Hrsg) Forensische Medizin. Volk und Gesundheit, Berlin, S 16–27
Schepel SJ, de Rooij NF, Koning G, Oeseburg B, Zijlstra WG (1984) In vivo experiments with a pH-ISFET electrode. Med Biol Eng Comput 22:6–11
Zink P (1970) Über das Verhalten des menschlichen Skelettmuskels bei Dehnung während des Verlaufs der Totenstarre. Habilitationsschrift Medizinische Fakultät Erlangen
Zink P (1972) Mechanische Eigenschaften lebensfrischer und totenstarrer menschlicher Skelettmuskelfasern und ganzer Muskeln. Z Rechtsmed 70:163–177
Author information
Authors and Affiliations
Additional information
Herrn Prof. Dr. H. Leithoff zum 65. Geburtstag gewidmet
Rights and permissions
About this article
Cite this article
Henßge, C., Lunkenheimer, P.P., Salomon, O. et al. Zur supravitalen elektrischen Erregbarkeit der Muskulatur. Z Rechtsmed 93, 165–174 (1984). https://doi.org/10.1007/BF00200446
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00200446