Abstract
To assess the sensitivity and specificity of HIV antibody detection in saliva we tested matched serum and saliva samples from HIV-infected and uninfected individuals. Saliva specimens were collected by two different devices of the Salivette system and stored at different temperatures. Samples were tested for HIV antibodies by two commercially available enzyme-linked immunosorbent assays (ELISAs; Wellcome, Biotest). HIV antibodies were detected in 98.5% (Wellcome) and 97.8% (Biotest) of the saliva samples (standard Salivettes) from 135 seropositive individuals. Using the Salivettes flavoured with citric acid the sensitivity was only 22.9%. No reactions in ELISA were found in saliva from HIV-seronegative individuals. Salivary HIV-specific IgA was detected in 90% of seropositive individuals. All positive saliva samples stored at room temperature were still reactive after 20 days; of those stored at 37°C, 23 out of 24 were positive when retested on day 5. Sensitivity of HIV antibody detection in saliva samples dried onto filter paper was 100% when a minimum of 100 μl of saliva was used. HIV antibody testing in saliva is an efficient tool for large scale epidemiological studies when standard Salivettes are used for sample collection. Saliva samples can be stored in Salivettes or dried onto filter paper for several days at room temperature and under tropical conditions (37°C).
Similar content being viewed by others
References
Behets FM, Edidi B, Quinn TC, Atikala L, Bishagara K, Nzila N, Laga M, Piot P, Ryder RW, Brown CC (1991) Detection of salivary HIV-1-specific IgG antibodies in high-risk populations in Zaire. J AIDS 4:183–187
Centers for Disease Control (1986) Classification system for human T-lymphotropic virus type III/lymphadenopathy-associated virus infections. Morbid Mortal Weekly Rep 35:334–339
Challacombe S, Sweet S (1992) Mucosal IgA and IgA subclass responses in HIV infection. 8. International AIDS, Volumes of Abstracts, Vol 2, PoA 2243, Amsterdam, Congrex Holland B.V.
Crofts N, Nicholson S, Coghlan P, Gust ID (1991) Testing of saliva for antibodies to HIV-1. AIDS 5:561–563
Goetzens M, Pfützner A, Brede HD, Rübsamen-Waigmann H (1990) Detection of HIV antibodies in saliva. Microbiologist 1:87–89
Johnson AM, Parry JV, Best SJ, Smith AM, de Silva M, Mortimer PP (1988) HIV surveillance by testing saliva. AIDS 2:369–371
Major CJ, Read SE, Coates RA, Francis A, McLaughlin BJ, Millson M, Shepherd F, Fanning M, Calzavara L, MacFadden D, Johnson JK, O'Shaughnessy MV (1991) Comparison of saliva and blood for human immunodeficiency virus prevalence testing. J Infect Dis 163:699–702
O'Shea S, Cordery M, Barren WY, Richman DD, Bradbeer C, Banatvala JE (1990) HIV excretion patterns and specific antibody responses in body fluids. J Med Virol 31:291–296
Soto-Ramirez LE, Hernandez-Gomez L, Sifuentes-Osornio J, Barriga-Angulo G, De Lima DD, Lopez-Portillo M, Ruiz-Palacios GM (1992) Detection of specific antibodies in gingival crevicular transudate by enzyme-linked immunosorbent assay for diagnosis of human immunodeficiency virus type 1 infection. J Clin Microbiol 30:2780–2783
Thieme TR, Fitchen JH (1992) Oral fluid sampling for determination of HIV-1 antibody serostatus. 8. International Conference on AIDS, Volumes of Abstracts, Vol 2, PoC 4501, Amsterdam, Congrex Holland B.V.
Van den Akker R, van den Hoek JAR, van den Akker WMR, Kooy H, Vijge E, Roosendaal G, Coutinho RA, van Loon AM (1992) Detection of HIV antibodies in saliva as a tool for epidemiological studies. AIDS 6:953–957
World Health Organization (1991) Proposed WHO criteria for interpreting Western Blot assay for HIV-1, HIV-2, and HTLV-I/HTLV-II. Bull WHO 5:561–563
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Stark, K., Warnecke, C., Brinkmann, V. et al. Sensitivity of HIV antibody detection in saliva. Med Microbiol Immunol 182, 147–151 (1993). https://doi.org/10.1007/BF00190267
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00190267