Reproducibility of the data determined by scanning laser polarimetry

  • Clinical Investigations
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

• Background: Scanning laser polarimetry is a tool for measuring the retinal nerve fiber layer: both its cross-sectional surface (polarimetric data analysis) and its thickness (mean sector values). • Methods: Two observers examined 56 normal volunteers twice by means of scanning laser polarimetry (Nerve Fiber Analyzer type 1, software version 1.6). Measurements of the retinal nerve fiber layer were carried out in four equal sectors of a circle around the optic nerve head. The measured values of the sectors and the calculated ratios among them were used for statistical analysis. Interobserver and intraobserver reproducibility were analyzed following a balanced random three-way cross classification with interactions. Interobserver reproducibility was defined as the part of variance not influenced by the observers. Intraobserver reproducibility was defined as the part of variance not influenced by the time. • Results: For repeated measurements of the retinal nerve fiber layer, better intraobserver than interobserver reproducibility was found (0.57–0.79 vs 0.11–0.44). The interobserver reproducibility was improved (0.24–0.65) in comparison to the intraobserver reproducibility (0.32–0.68) by calculating the ratios of the measured values. • Conclusion: The instrument is clinically useful only if used by the same observer. If measurements are performed by different observers the ratios of the measurements must be used. Further development in the apparatus is needed to improve interobserver reproducibility.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Caprioli J (1990) The contour of the juxtapapillary nerve fiber layer in glaucoma. Ophthalmology 97:358–366

    Google Scholar 

  2. Caprioli J, Miller JM (1989) Measurement of relative nerve fiber layer surface height in glaucoma. Ophthalmology 96:633–641

    Google Scholar 

  3. Dreher AW, Reiter K (1992) Retinal laser ellipsometry: a new method for measuring the retinal nerve fiber layer thickness distribution? Clin Vision Sci 7:481–488

    Google Scholar 

  4. Eikelboom RH, Cooper RL, Barry CJ (1990) A study of variance in densitometry of retinal nerve fiber layer photographs in normals and glaucoma suspects. Invest Ophthalmol Vis Sci 31:2373–2383

    Google Scholar 

  5. Hee MR, Izatt JA, Swanson A, Huang D, Schuman JS, Lin P, Puliafito CA, Fujimoto G (1995) Optical coherence tomography of the human retina. Arch Ophthalmol 113:325–332

    Google Scholar 

  6. Johnson CA, Brandt JD, Khong AM, Adams AJ (1995) Short-wavelength automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes. Arch Ophthalmol 113:70–76

    Google Scholar 

  7. Jonas JB, Nguyen NX, Naumann GOH (1989) The retinal nerve fiber layer in normal eyes. Ophthalmology 96:627–632

    Google Scholar 

  8. Puliafito CA, Hee MR, Lin CP, Reichel E, Schuman JS, Duker JS, Izatt JA, Swanson EA, Fujimoto JG (1995) Imaging of macular diseases with optical coherence tomography. Ophthalmology 102:217–229

    Google Scholar 

  9. Quigley HA, Addicks EM (1982) Quantitative studies of retinal nerve fiber laser defects. Arch Ophthalmol 100:807–814

    Google Scholar 

  10. Quigley HA, Dunkelberger GR, Green WR (1989) Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 107:453–464

    Google Scholar 

  11. Radius RL (1980) Thickness of the retinal nerve fiber layer in primate eyes. Arch Ophthalmol 98:1625–1629

    Google Scholar 

  12. Rohrschneider K, Burk ROW, Kruse FE, Völcker HE (1993) In vivo measurements of the retinal nerve fiber layer thickness using laser polarimetry. Klin Monatsbl Augenheilk 203:200–205

    Google Scholar 

  13. Schumann JS, Hee MR, Puliafito CA, Wong C, Pedut-Kloizman T, Lin CP, Hertzmark E, Izatt JA, Swanson EA, Fujimoto JG (1995) Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol 113:586–596

    Google Scholar 

  14. Sommer A, Katz J, Quigley HA, Miller NR, Robin AL, Richter RC, Witt KA (1991) Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol 109:77–83

    Google Scholar 

  15. Weinreb RN, Dreher AW, Coleman A, Quigley H, Shaw B, Reiter K (1990) Histopathologic validation of Fourierellipso-metry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol 108:557–560

    Google Scholar 

  16. Weinreb RN, Shakiba S, Zangwill L (1995) Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 119:627–636

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

The Nerve Fiber Analyzer is a product of Laser Diagnostic Technologies, 9550 Waples Street, Suite 105, San Diego, CA 92121, USA. The authors have no financial interest in the apparatus used in this study

Rights and permissions

Reprints and permissions

About this article

Cite this article

Junghardt, A., Schmid, M.K., Schipper, I. et al. Reproducibility of the data determined by scanning laser polarimetry. Graefe's Arch Clin Exp Ophthalmol 234, 628–632 (1996). https://doi.org/10.1007/BF00185296

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00185296

Keywords

Navigation