Abstract
• Background: Scanning laser polarimetry is a tool for measuring the retinal nerve fiber layer: both its cross-sectional surface (polarimetric data analysis) and its thickness (mean sector values). • Methods: Two observers examined 56 normal volunteers twice by means of scanning laser polarimetry (Nerve Fiber Analyzer type 1, software version 1.6). Measurements of the retinal nerve fiber layer were carried out in four equal sectors of a circle around the optic nerve head. The measured values of the sectors and the calculated ratios among them were used for statistical analysis. Interobserver and intraobserver reproducibility were analyzed following a balanced random three-way cross classification with interactions. Interobserver reproducibility was defined as the part of variance not influenced by the observers. Intraobserver reproducibility was defined as the part of variance not influenced by the time. • Results: For repeated measurements of the retinal nerve fiber layer, better intraobserver than interobserver reproducibility was found (0.57–0.79 vs 0.11–0.44). The interobserver reproducibility was improved (0.24–0.65) in comparison to the intraobserver reproducibility (0.32–0.68) by calculating the ratios of the measured values. • Conclusion: The instrument is clinically useful only if used by the same observer. If measurements are performed by different observers the ratios of the measurements must be used. Further development in the apparatus is needed to improve interobserver reproducibility.
Similar content being viewed by others
References
Caprioli J (1990) The contour of the juxtapapillary nerve fiber layer in glaucoma. Ophthalmology 97:358–366
Caprioli J, Miller JM (1989) Measurement of relative nerve fiber layer surface height in glaucoma. Ophthalmology 96:633–641
Dreher AW, Reiter K (1992) Retinal laser ellipsometry: a new method for measuring the retinal nerve fiber layer thickness distribution? Clin Vision Sci 7:481–488
Eikelboom RH, Cooper RL, Barry CJ (1990) A study of variance in densitometry of retinal nerve fiber layer photographs in normals and glaucoma suspects. Invest Ophthalmol Vis Sci 31:2373–2383
Hee MR, Izatt JA, Swanson A, Huang D, Schuman JS, Lin P, Puliafito CA, Fujimoto G (1995) Optical coherence tomography of the human retina. Arch Ophthalmol 113:325–332
Johnson CA, Brandt JD, Khong AM, Adams AJ (1995) Short-wavelength automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes. Arch Ophthalmol 113:70–76
Jonas JB, Nguyen NX, Naumann GOH (1989) The retinal nerve fiber layer in normal eyes. Ophthalmology 96:627–632
Puliafito CA, Hee MR, Lin CP, Reichel E, Schuman JS, Duker JS, Izatt JA, Swanson EA, Fujimoto JG (1995) Imaging of macular diseases with optical coherence tomography. Ophthalmology 102:217–229
Quigley HA, Addicks EM (1982) Quantitative studies of retinal nerve fiber laser defects. Arch Ophthalmol 100:807–814
Quigley HA, Dunkelberger GR, Green WR (1989) Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 107:453–464
Radius RL (1980) Thickness of the retinal nerve fiber layer in primate eyes. Arch Ophthalmol 98:1625–1629
Rohrschneider K, Burk ROW, Kruse FE, Völcker HE (1993) In vivo measurements of the retinal nerve fiber layer thickness using laser polarimetry. Klin Monatsbl Augenheilk 203:200–205
Schumann JS, Hee MR, Puliafito CA, Wong C, Pedut-Kloizman T, Lin CP, Hertzmark E, Izatt JA, Swanson EA, Fujimoto JG (1995) Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol 113:586–596
Sommer A, Katz J, Quigley HA, Miller NR, Robin AL, Richter RC, Witt KA (1991) Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol 109:77–83
Weinreb RN, Dreher AW, Coleman A, Quigley H, Shaw B, Reiter K (1990) Histopathologic validation of Fourierellipso-metry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol 108:557–560
Weinreb RN, Shakiba S, Zangwill L (1995) Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 119:627–636
Author information
Authors and Affiliations
Additional information
The Nerve Fiber Analyzer is a product of Laser Diagnostic Technologies, 9550 Waples Street, Suite 105, San Diego, CA 92121, USA. The authors have no financial interest in the apparatus used in this study
Rights and permissions
About this article
Cite this article
Junghardt, A., Schmid, M.K., Schipper, I. et al. Reproducibility of the data determined by scanning laser polarimetry. Graefe's Arch Clin Exp Ophthalmol 234, 628–632 (1996). https://doi.org/10.1007/BF00185296
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00185296