Abstract
The detection of preserved glucose uptake in hypoperfused dysfunctional myocardium by fluorine-18 deoxyglucose (FDG) positron emission tomography (PET) represents the method of choice in myocardial viability diagnostics. As the technique is not available for the majority of patients due to cost and the limited capacity of the PET centres, it was the aim of the present work to develop and test FDG single-photon emission tomography (SPET) with the means of conventional nuclear medicine. The perfusion marker sestamibi (MIBI) was used together with the metabolic tracer FDG in dual-isotope acquisition. A conventional SPET camera was equipped with a 511-keV collimator and designed to operate with simultaneous four-channel acquisition. In this way, the scatter of 18F into the technetium-99m energy window could be taken into account by a novel method of scatter correction. Thirty patients with regional wall motion abnormalities at rest were investigated. The results of visual wall motion analysis by contrast cine-ventriculography in nine segments/heart were compared with the results of quantitative scintigraphy. The scintigraphic patterns of MIBI and FDG tracer accumulation were defined as normal, matched defects and perfusion-metabolism mismatches. Spatial resolution of the system was satisfactory, with a full width at half maximum (FWHM) of 15.2 mm for 18F and 14.0 mm for 99mTe, as measured by planar imaging in air at 5 cm distance from the collimator. Image quality allowed interpretation in all 30 patients. 88% of segments without relevant wall motion abnormalities presented normal scintigraphic results. Seventy-five akinetic segments showed mismatches in 27%, matched defects in 44% and normal perfusion in 29%. We conclude that FDG-MIBI dual-isotope SPET is technically feasible with the means of conventional nuclear medicine. Thus, the method is potentially available for widespread application in patient care and may represent an alternative to the 201T1 reinjection technique.
Similar content being viewed by others
References
Braunwald E, Rutherford JD. Reversible ischemic left ventricular dysfunction: “evidence for the hibernating myocardium”. J Am Coll Cardiol 1986; 8: 1467–1470.
Braunwald E, Kloner RA. The stunned myocardium: prolonged postischemic ventricular dysfunction. Circulation 1982; 66: 1146–1149.
Schwaiger M, Brunken R, Grover-McKay M, Krivokapich J, Child J, Tillisch JH, Phelps ME, Schelbert HR. Regional myocardial metabolism in patients with acute myocardial infarction assessed by positron emission tomography. J Am Coll Cardiol 1986; 8: 800–808.
Tillisch J, Brunken R, Marshall R, Schwaiger M, Mandelkern M, Phelps M, Schelbert HR. Reversibility of cardiac wall motion abnormalities predicted by positron tomography. N Engl J Med 1986; 314: 884–888.
Nienaber C, Brunken R, Sherman CT, Yeatman LA, Gambhir SS, Krivokapich J, Demer LL, Ratib O, Child JS, Phelps ME, Schelbert HR. Metabolic and functional recovery of ischemic human myocardium after coronary angioplasty. J Am Coll Cardiol 1991; 18: 966–978.
Oberhausen E, Berberich R, Ruth T, Özbek C, Hellwig N. F-18-FDG Szintigraphic mit einem Ein-Kopf-SPECT System zur Erkennung von “hibernating myocardium” and von Lungentumoren. In: Höfer R, Bergmann H, Sinzinger H, (eds) Radioactive isotopes in clinical medicine and research, 20th International Symposium Badgastein, January 7–10, 1992, pp 87–90.
Höflin F, Rösler H, Ledermann H, Romanello S, Weinreich R. Detection of nonperfused, viable myocardium with 18F-FDG using a specially designed gamma camera. A simple method to detect hibernating myocardium. Acta Radiol Suppl (Stockh) 1991; 376: 133–134.
Van Lingen A, Huijgens PC, Visser FC, Ossenkoppele GJ, Hoekstra OS, Martens HIM, Huitnik H, Herscheid KDM, Green MV, Teule GJJ. Performance characteristics of a 511-keV collimator for imaging positron emitters with a standard gamma-camera. Eur J Nucl Med 1992; 19: 315–321.
Williams KA, Taillon LA, Stark VJ. Quantitative planar imaging of glucose metabolic activity in myocardial segments with exercise thallium-201 perfusion defects in patients with myocardial infarction: comparison with late (24-hour) redistribution thallium imaging for detection of reversible ischemia. Am Heat J 1992; 124: 294–304.
Gallagher BM, Fowler JS, Gutterson NI, MacGregor RR, Wan CN, Wolf AP Metabolic trapping as a principle of radiopharmaceutical design: some factors responsible for the biodistribution of 18F 2-deoxy-2-fluoro-shirlyD-glucose. J Nucl Med 1978; 19:1154–1161.
Phelps ME, Hoffman EJ, Selin C, Huang SC, Robinson G, MacDonald N, Schelbert H, Kuhl DE. Investigation of [18F] 2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism. J Nucl Med 1978; 19: 1311–1319.
Altehöfer C, Kaiser HJ, Dörr R, Feinendegen C, Beilin I, Übis R, Bull U. Fluorine-18 deoxyglucose PET for assessment of viable myocardium in perfusion defects in 99mTc-MIBI SPET: a comparative study in patients with coronary artery disease. Eur J Nucl Med 1992; 19: 334–342.
Lucignani G, Paolini G, Landoni C, Zuccari M, Paganelli G, Galli L, Di Credico G, Vanoli G, Rossetti C, Mariani MA, Gilardi MC, Colombo F, Grossi A, Fazio F. Presurgical identification of hibernating myocardium by combined use of technetium-99m hexakis 2-methoxyisobutylisonitrile single photon emission tomography and fluorine-18 fluoro-2-deoxy-shirlyD-glucose positron emission tomography in patients with coronary artery disease. Eur J Nucl Med 1992; 19: 874–881.
Özbek C, Dyckmans F, Sen S, Schieffer H and the SIAM-Study Group. Comparison of ivasive and comserative strategies after treatment with streptokinase in acute myocardial infarction. Results of a randomised trial (SIAM). J Am Coll Cardiol 1990; 15 (Supl.): 63A.
Jaszczak RJ, Greer KL, Floyd CE, Harris CC, Coleman RE. Improved SPET quantification using compensation for scattered photons. J Nucl Med 1984; 25: 893–900.
Berberich R, Brill G, Schmidt EL. Verbesserung des Auflösungsvermögens der Gammakamera durch gewichtete Subraktion der Streustahlung. Nuc Compact 1984; 15: 246–251.
Altehöfer C, vom Dahl J, Bull U, Uebis R, Kleinhans E, Hanrath P. Comparison of thallium-201 single-photon emission tomography after rest injection and fluorodeoxyglucose positron emission tomography for assessment of myocardial viability in patients with chronic coronary artery disease. Eur J Nucl Med 1994; 21: 37–45.
Kiat H, Berman DS, Maddahi J, De Yang L, Van Train K, Rozanski A, Friedman J. Late reversibility of tomographic myocardial thallium-201 defects: an accurate marker of myocardial viability. J Am Clin Cardiol 1988; 12: 1456–1463.
Dilsizian V, Rocco TP, Freedman NMT, Leon MB, Bonow RO. Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging. N Engl J Med 1990; 323: 141–146.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Stoll, HP., Hellwig, N., Alexander, C. et al. Myocardial metabolic imaging by means of fluorine-18 deoxyglucose/technetium-99m sestamibi dual-isotope single-photon emission tomography. Eur J Nucl Med 21, 1085–1093 (1994). https://doi.org/10.1007/BF00181063
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00181063