Skip to main content

Advertisement

Log in

Indications des scintigraphies au Gallium 67 et aux leucocytes marqués à l'Indium 111 dans la mise au point des infections postopératoires en chirurgie osteo-articulaire

Comparison of the use of Indium 111 labelled leucocyte scan and Gallium 67 in the diagnosis of post-operative infection

  • Published:
International Orthopaedics Aims and scope Submit manuscript

Summary

A prospective scintigraphic study using Gallium 67 and granulocytes labelled with Indium 111 was carried out in 60 patients who were thought to have infection following orthopaedic operations. Both investigations gave positive results in 11 of the 16 infections observed. The Indium 111 labelled leucocyte scan was more accurate than the Gallium 67 studies in delineating patients who did not have an infection, and appears to be more reliable in the diagnosis of post-operative sepsis.

Résumé

S'appuyant sur une étude prospective de 60 patients, les auteurs présentent leurs indications des scintigraphies au Gallium 67 et aux leucocytes marqués à l'Indium 111 le diagnostic des infections postopératoires précoces en chirurgie orthopédique. Les deux scintigraphies concordent et sont pathologiques pour 11 de 16 infections démontrées. La scintigraphie aux leucocytes marqués à l'Indium 111 s'est révélée être plus fiable que la scintigraphie au Gallium 67 pour le reste des patients non infectés. Elle constitue pour les auteurs la scintigraphie de choix dans le diagnostic des infections post-opératoires précoces.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Références

  1. Brown ML, Fitzgerald RH, Dewanjee MR (1982) Indium 111 leukocyte imaging in low grade osteomyelitis. Work in progress. J Nucl Med 3:65

    Google Scholar 

  2. Cutler JE (1974) A vinyle in vitro method for studies on chemotaxis. Proc J Soc Exp Biol Med 147:471–474

    Google Scholar 

  3. de Mourgues J, Moyens B (1980) Le risque infectieux en chirurgie orthopédique. Encycl Med-Chir, Editions techniques SA, Paris, Techniques Chirurgicales, Orthopédie, 4.5.04, 1–10, 44005

  4. Mc Afee, JG (1984) Technique of leukocyte harvesting and labeling: problems and perspectives. Sem Nucl Med XIV, 2

  5. Merkel KD, Brown ML, Fitzgerald RH, Dewanjee MK, Hauser MF (1983) Prospective Indium 111 WBC scan versus Tc-99m — MDF — Gallium 67 scan for low-grade osteomyelitis. Final report. J Nucl Med Proc 30th Ann Meet 24, 5:72

    Google Scholar 

  6. Merkel KD, Brown ML, Fitzgerald RH (1983) Evaluating the painful prosthetic joint with sequential Tc-99m — MDP — Gallium 67. J Nucl Med Proc 30th Ann Meet 24, 5:72

    Google Scholar 

  7. Merkel KD, Brown ML, Dewanjee MK, Fitzgerald RH Jr (1985) Comparison of Indium — labeled-leukocytes imaging with sequential technetium — Gallium scanning in the diagnosis of low-grade musculoskeletal sepsis. J Bone Jt Surg [Am] 67:3

    Google Scholar 

  8. Metz CE (1978) Basic principles of roc analysis. Sem Nucl Med 8:283–298

    Google Scholar 

  9. Mulamba AH, Ferrant A, Leners N, de Nayer P, Rombouts JJ, Vincent A (1983) Indium 111 leukocyte scanning in the evaluation of painful hip arthroplasty. Acta Orthop Scand 54:695–697

    Google Scholar 

  10. Pring DJ, Henderson RG, Keshavarian A, Rivet AG, Krausz T, Coombs RRH, Lavender JP (1986) Imaging granulocyte scanning in the painful prosthetic joint. AJR 146:167–172

    Google Scholar 

  11. Pring DJ, Henderson RG, Rivet AG, Drausz T, Coobs RRH, Lavender JP (1986) Autologus granulocyte scanning of painful prosthetic joint. J Bone Jt Surg [Br] 68:647–652

    Google Scholar 

  12. Schauwecker DS, Park HM, Mock BH, Burt RW, Kernick CB, Ruof III AC, Sinn HJ, Wellmann HN (1984) Evaluation of complicating osteomyelitis with Tc-99m, MDP, In-111 granulocytes and Ga-67 citrate. J Nucl Med 2, 25:849–853

    Google Scholar 

  13. Sfakianakis GM, Al-Sheikh W, Heal A, Rodman G Jr, Zeppa R and Serafini A (1981) A prospective comparative study of the sensibility and specificity of Indium 111 leukocyte and Gallium 67 scintigraphy. J Nucl Med Proc 28th Ann Meet 56

  14. Sfakianakis GN, Al-Sheikh W, Heal AM, Serafini A (1982) The sensitivity, specificity and accuracy of Indium 111, WBC and Gallium 67 scintigraphy in a population with acute and chronic infections. J Nucl Med Proc 29th Ann Meet 23, 5:65

    Google Scholar 

  15. Turner DA (1978) An intuitive approach to Receiver Operating Characteristic Curve analysis. J Nucl Med 19:213–220

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mokassa, L.B., Wagner, J. & Verhas, M. Indications des scintigraphies au Gallium 67 et aux leucocytes marqués à l'Indium 111 dans la mise au point des infections postopératoires en chirurgie osteo-articulaire. International Orthopaedics 14, 155–159 (1990). https://doi.org/10.1007/BF00180121

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00180121

Navigation