Skip to main content

Advertisement

Log in

Volume rendering and bicolour scale in double isotope studies: application to immunoscintigraphy and bone landmarking

  • Short Communication
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Combining the volume rendering and bicolour visualization tehniques is proposed as an aid in interpreting single photon emission tomography (SPET) immunoscintigraphy (IS) recorded simultaneously with SPET bone landmarking (BL). The combination helps in localizing abnormal monoclonal uptake and in differentiating it from a physiological radioactivity distribution. The so-called rendered images (RIs) are obtained in both IS and BL studies according to a depth- weighted maximum activity projection algorithm. Fused BL and IS RIs are constructed by a simple, pixel by pixel addition. They are displayed using a bicolour grey-red scale, which makes it possible to visualize both studies by a transparency effect. This method was applied to patients suspected of suffering colorectal or ovarian cancer recurrences, in whom monoclonal antibodies against carci-noembryonic antigen, B72-3 or OC125 labelled with indium-111 were used.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  • Bunker SR, Torre DM, Schmidt WP, Handmaker H (1988) Bladder artefact correction for the SPELT evaluation of the hips (abstr). J Nucl Med 29:780

    Google Scholar 

  • Chatal JF, Fumoleau P, Saccavini JC, Thedrez P, Curtet C, Bianco-Arco A, Chetanneau A, Peltier P (1987) Immunoscintigraphy of recurrences of gynecologic carcinomas. J Nucl Med 28:1807–1819

    Google Scholar 

  • Pitcher EM, Stevens PH, Davies ER, Goddard PR, Jackson PC (1985) Transfer and combination of digital image data. Br J Radiol 58:701–703

    Google Scholar 

  • Shih WJ, Magoun S, Stipp V, Wierzbinski B, Gross K, Mills BJ, Ryo UY (1991) Volume three-dimensional display of Tc-99m HMDP skull, cervical vertebra, thoracic vertebral, lumbar vertebral and/or pelvic SPELT images by triple head gamma camera (abstract). J Nucl Med 32:913–914

    Google Scholar 

  • Wallis JW, Miller TR (1990) Volume rendering in three-dimensional display of SPELT images. J Nucl Med 31:1421–1428

    Google Scholar 

  • Wallis JW, Miller TR (1991) Three-dimensional display in nuclear medicine and radiology. J Nucl Med 32:534–546

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Offprint requests to: A. Loboguerrero

Rights and permissions

Reprints and permissions

About this article

Cite this article

Loboguerrero, A., Pérault, C. & Liehn, J.C. Volume rendering and bicolour scale in double isotope studies: application to immunoscintigraphy and bone landmarking. Eur J Nucl Med 19, 201–204 (1992). https://doi.org/10.1007/BF00173282

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00173282

Key words

Navigation