Abstract
The amplitude of the intraocular pressure pulse and pulsatile ocular blood flow (POBF) were correlated with the axial length and refraction of 68 eyes of healthy subjects. Measurements were obtained with subjects in the sitting position using an ophthalmic Ascan and a pneumotonometer linked to a Langham ocular blood-flow system. The amplitude of the ocular pulse and the magnitude of POBF were found to decrease with increasing axial length (r = −0.61, P < 0.001 and r = −0.74, P < 0.001, respectively). A similar close relationship was found between the ocular pulse amplitude and POBF and the refractive state of the eye (r = 0.63, P < 0.001 and r = 0.7, P < 0.001, respectively). The reasons for the association are discussed and the importance of the observations in the construction of studies in which ocular pulse amplitude or POBF are to be measured in different groups of subjects is emphasised.
Similar content being viewed by others
References
Abdalla MI, Hamdi M (1970) Applanation ocular tension in myopia and emmetropia. Br J Ophthalmol 54:122–125
Avetisov ES, Savitskaya NF (1977) Some features of the ocular microcirculation in myopia. Ann Ophthalmol 9:1261–1264
Bosley TM, Savino PJ, Sergott RC, Eagle RC, Sandy R, Gee W (1989) Ocular pneumoplethysmography can help in the diagnosis of giant cell arteritis. Arch Ophthalmol 107:379–381
Bron AJ, Knox DL, Gaasterland D (1967) Tonographic studies in carotid occlusive disease. Br J Ophthalmol 51:577–595
Bynke HG, Schele B (1967) On the origin of the ocular pulse. Ophthalmologica 153:29–36
Eisenlohr J, Langham ME, Maumenee AE (1962) Manometric studies of the pressure/volume relationships in living and enucleated eyes of individual subjects. Br J Ophthalmol 46:536–548
Friedenwald JS (1937) Contribution to the theory and practice of tonometry. Am J Ophthalmol 20:985–1024
Honmura S (1968) Studies on the relationship between ocular tension and myopia: II. Ocular tension, ocular rigidity, aqueous outflow and aqueous secretion in myopic eyes. Acta Soc Ophthalmol Jpn 72:74–82
Lambrou GN, Sindhunata P, Berg TJTP van den, Geijssen CH, Vyborny P, Greve E (1989) Ocular pulse measurements in low-tension glaucoma. In: Lambrou GN, Greve EL (eds) Ocular bloodflow in glaucoma. Kugler and Ghedini, Amsterdam, pp 115–120
Langharn ME, Kramer T (1990) Decreased choroidal blood flow associated with retinitis pigmentosa. Eye 4:374–381
Langham ME, To'mey KF (1978) A clinical procedure for the measurement of ocular pulse pressure relationship and the ophthalmic artery pressure. Exp Eye Res 27:17–25
Langham ME, Farrell RA, O'Brien V, Silver DM, Schilder P (1989) Blood flow in the human eye. Acta Ophthalmol [Suppl] 191:9–13
Perkins ES (1981) Ocular volume and ocular rigidity. Exp Eye Res 33:141–145
Perkins ES (1981) The ocular pulse. Curr Eye Res 1:19–23
Perkins ES (1985) The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis. Br J Ophthalmol 69:676–680
Silver DM, Farrell RA, Langham ME, O'Brien V, Schilder P (1989) Estimation of pulsatile ocular blood flow from intraocular pressure. Acta Ophthalmol [Suppl] 191:25–29
To'mey KF, Faris BM, Jalkh AE, Nasr AM (1981) Ocular pulse in myopia: a study of 40 eyes. Ann Ophthalmol 13:569–571
Tomlinson A, Phillips CI (1970) Applanation tension and axial length of the eye. Br J Ophthalmol 54:548–553
Author information
Authors and Affiliations
Additional information
Offprint requests to: C.B. James
Rights and permissions
About this article
Cite this article
James, C.B., Trew, D.R., Clark, K. et al. Factors influencing the ocular pulse — axial length. Graefe's Arch Clin Exp Ophthalmol 229, 341–344 (1991). https://doi.org/10.1007/BF00170692
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00170692