Abstract
A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20–50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as activity retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients.
References
Hemming RW. Chebyshev approximation and Chebyshev filters. In: Digital filters. Trentic; 1977:196–212
Urbain JC, Siegel JA, Charkes ND, Maurer AH, Malmud LS, Fisher RS. The two component stomach: effects of meal particle size on fundal and antral emptying. Eur J Nucl Med 1989; 15:254–259
Christian PE, Datz FL, Sorenson JA, Taylor A. Technical factors in gastric emptying studies. J Nucl Med 1983; 24:264–267
Digenis GA, Beihn RM, Theodorakis MC, Shambhu MB. Use of 99mTc-labeled triethylenetetramine-polystyrene resin for measuring the gastric emptying rate in humans. J Pharmacol Sci 1977; 66:442–443
Theodorakis MC, Groutas WC, Whitlock TW, Trans K. Tc99m-labeled polystyrene and cellulose macromolecules: agents for gastrointestinal scintigraphy. J Nucl Med 1982; 23:693–697
McCallum RW. Motor function of the stomach in health and disease. In: Sleisenger MH, Fordtran JS, eds. Gastrointestinal disease, 4th edn. Philadelphia: Saunders; 1989:675–713
Moore JG, Christian PE, Coleman RE. Gastric emptying of varying meal weight and composition in man. Evaluation by dual liquid- and solid-phase isotopic method. Dig Dis Sci 1981; 26:16–22
Moore JG, Datz FL, Christian PE. Effect of body posture on radionuclide measurements of gastric emptying. Dig Dis Sci 1988; 33:1592–1595
Datz FL, Christian PE, Moore JG. Differences in gastric emptying rates between menstruating and postmenopausal women. J Nucl Med 1987; 28:604–605
Meyer JH, VanDeventer G, Graham LS, Thomson J, Thomasson D. Errors and corrections with scintigraphic measurement of gastric emptying of solid foods. J Nucl Med 1983; 24:197–203
Christian PE, Moore JG, Sorenson JA, Coleman RE, Weich DE. Effects of meal size and correction technique on gastric emptying time: studies with two tracers and opposed detectors. J Nuel Med 1980; 21:883–885
Gardner E. Esophagus, stomach, and intestine. In: Gardner E, O'Gray DJ, O'Rahilly R, eds. Anatomy, 3rd edn. Philadelphia: Saunders; 1969:397–402
Thum P, Bücheler E. Röntgendiagnostik der inneren Organe. In: Einführung in die Röntgendiagnostik 7th edn. Stuttgart: Thieme; 1982:346–355
Elashoff JD, Reedy TJ, Meyer JH. Analysis of gastric emptying. Gastroenterology 1982; 83:1306–1312
Author information
Authors and Affiliations
Additional information
Correspondence to: R.W Lipp
Rights and permissions
About this article
Cite this article
Lipp, R.W., Hammer, H.F., Schnedl, W. et al. A simple scintigraphic method for continuous monitoring of gastric emptying. Eur J Nucl Med 20, 260–263 (1993). https://doi.org/10.1007/BF00170009
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00170009