Abstract
Lens reflectometry is a useful method of determining the back scatter of light from the cataractous lens. Making use of normal programmes, the personal computer can be used for the quantitative determination of the lens reflex, as seen in the slit-lamp image. If three different images of the same eye are compared, it appears that the mean variation in the back-scatter readings made by our method is 8.3%.
Similar content being viewed by others
References
Benedek GB. Theory of transparency of the eye. Applied Optics 1971; 10 (3): 459–473.
Mallerio J. Light absorption and scatter in the human lens. Vision Res 1971; 11: 129–141.
Sample PA, Esterson FD, Weinreb RN, Boynton RM. The aging lens: in vivo assessment of light absorption in 84 human eyes. Invest Ophthalmol Vis Sci 1988; 29: 1306–1311.
Paulsson LE, Sjöstrand J. Contrast sensitivity in the presence of a glare light. Invest Ophthalmol Vis Sci 1980; 19: 401–406.
Miller D, Nadler MP. Light scattering: its relationship to glare and contrast in patients and normal subjects. In: Nadler MP, Miller D, Nadler DJ, eds. Glare and contrast sensitivity for clinicians. New York: Springer, 1990.
Bettelheim FA, Chylack LT. Light scattering of whole excised human cataractous lenses. Relationship between different light scattering parameters. Exp Eye Res 1985; 41: 19–30.
Ben-Sira I, Weinberger D, Bodenheimer J, Yassur Y. Clinical method for measurement of light backscatter from the in vivo human lens. Invest Ophthamol Vis Sci 1980; 19: 435–437.
Sigelman J, Trokel SL, Spector A. Quantitative biomicroscopy of lens light back scatter. Arch Ophthalmol 1974; 92: 437–442.
Hockwin O, Dragomirescu V, Laser H. Measurements of lens transparency or its disturbances by densitometric image analysis of Scheimpflug photographs. Graef's Arch Clin Exp Ophthalmol 1982; 219: 255–262.
Flammer J, Bebie H. Lens opacitiy meter: a new instrument to quantify lens opacity. Ophthalmologica 1987; 19: 69–72.
Lee JA, Taylor HR. Evaluation of photographic methods for documentation of lens opacities. Invest Ophthalmol Vis Sci 1990; 31: 1191–1193.
Laser H, Berndt W, Leyendecker M, Kojima M, Hockwin O, Cheyne A. Comparision between Topcon SL-45 and SL-45B with different correction methods for factors influencing Scheimpflug examination. Ophthalmic Res 1990; 22 (suppl): 9–17.
van den Brom HJB, Kooijman AC, Blanksma LJ. Clinical and physical measurements of the cataractous lens. Doc Ophthalmol 1990; 75: 247–258.
van den Berg JTP. Importance of pathological intraocular light scatter for visual disability. Doc Opthalmol 1986; 61: 327–333.
Jacobs R, Krohn DL. Fluorescence intensity profile of the human lens sections. Inv Ophthalmol Vis Sci 1981; 20: 117–120.
van Best JA, Tjin A Tsoi EWSJ, Boot JP, Oosterhuis JA. In vivo assessment of lens transmission for bleu-green light by autofluorescence measurement. Ophthalmic Res 1985; 17: 90–95.
West SK, Rosenthal F, Newland HS, Taylor HR. Use of photographic techniques to grade nuclear cataracts. Inv Ophthalmol Vis Sci 1988; 29: 73–77.
Adamsons I, Taylor KI, Enger C, Taylor HR. A new method for documenting lens opacities. Am J Ophthalmol 1991; 111: 65–70.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Van Den Brom, H.J.B., Siertsema, J.V., Kooijman, A.C. et al. Lens reflectometry with a CCD video camera and computer image analysis. Doc Ophthalmol 78, 237–244 (1991). https://doi.org/10.1007/BF00165686
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00165686