Abstract
This report details the influence of the time lapse and surface area size of intravitreal copper foreign bodies on the electroretinogram (ERG) and the recovery of the potentials after removal of the particles. Pure copper wires were implanted temporarily into the vitreous body of rat eyes in the area of the ora serrata and the values of the ERG were compared with those of the intact fellow eyes.
In three different procedures with groups of 12 animals each the following results were obtained: (1) The metal toxicity of small copper particles (0.3 mm2) remaining one day in the vitreous body reduced the amplitudes of the a1-, a2-, and b-wave only 10% by the end of the observation time of 260 days, (2) The loss of ERG amplitudes increased to about 25% under the influence of larger copper particles (1.3 mm2; time lapse one day); and (3) Copper particles with an active surface of 1.3 mm2 remaining two days in the vitreous body caused a permanent loss of about 50%.
Similar content being viewed by others
References
Boethius J and Knave B (1969) Effects of metallic ions on the membrane potential of frog skeletal muscle. In:Electroretinography in Eyes with Retained intraocular Metallic Foreign Bodies. Acta Ophthalmol Suppl (Kbn) 100, p 52
Cordes FC and Harrington DO (1935) Bilateral absorption of intraocular copper with chalcosis in one eye. Am J Ophthalmol 18:348–352
Delaney WV (1975) Presumed ocular chalcosis:A reversibel maculopathy. Ann Ophthalmol 7:378–380
Heilig P and Thaler A (1972) Augmented ERG amplitudes in chalcosis bulbi. Vis Res 11:1218
Knave B (1969) Electroretinography in eyes with retained intraocular metallic foreign bodies. Acta Ophthalmol Suppl (Kbn) 100
Knave B (1970) The ERG and ophthalmological changes in experimental metallosis in the rabbit. II. Effects of steel, copper and aluminium particles. Acta Ophthal (Kbh) 48:159–173
Marner E (1945) A case of ocular chalcosis with spontaneous resorption of the copper, and disappearance of the chalcosis. Acta Ophthalmol (Kbh) 23:171–174
Rosenthal AR, Appleton B and Hopkins JL (1974) Intraocular copper foreign bodies. Am J Ophthalmol 78:671–678
Saul WM (1976) Die Wirkung von Schwermetallionen auf zentralnervöse Gewebe - Elektroretinographische Untersuchungen an umströmten Froschnetzhäuten. Unpublished thesis, University of Cologne
Schmidt JGH and Ehring EWG (1986) On the recovery of the electroretinogram after removal of intravitreal lead particles. Doc Ophthalmol 62:181–190
Schmidt JGH and Hummelsheim St (1986) Über den Einfluß von Decadron-Phosphat auf die ophthalmoskopischen Veranderungen bei intravitrealen Messingdrähten. Klin Monatsbl Augenheilkd 188:234–238
Schmidt JGH, Mansfeld-Nies R and Nies C (1986a) Über die Rückbildungsfähigkeit von Netzhaut- und Glaskörper-Veränderungen nach Extraktion intravitrealer Kupferpartikel. Klin Monatsbl Augenheilkd 189:39–43
Schmidt JGH, Nies C and Mansfeld-Nies R (1986b) On the recovery of the electroretinogram after removal of intraocular zinc particles (submitted)
Schmidt JGH and Stute A (1972) Electroretinogram and ophthalmoscopic findings in intra-vitreous iron, copper and lead particles. 10th ISCERG Symposium Los Angeles, Doc Ophthalmol Proc Ser 15:85–90
Schmidt JGH, Stute A and Weber E (1972) Elektroretinographische und ophthalmoskopische Befunde bei intraokularen Metallfremdkörpern der Ratte. Ber Dtsch Ophthalmol Ges 71:391–396
Schmidt JGH and Wasserschaff MSJ (1983) On the recovery of the electroretinogram after removal of intravitreal iron particles. 20th ISCEV Symposium, Iowa City, Iowa. Doc Ophthalmol Proc Series 37:293–299
Schneider KU (1973) Untersuchungen über die Cu++-Intoxikation des isolierten Netzhautgewebes und ihre Beeinflussung durch Komplexbildner. Unpublished thesis, University of Cologne
Sickel W (1977) Experimentelle Elektroretinographie der Metallosen. In: Intraocularer Fremdkörper und Metallose, eds: Neubauer H, Rüssmann W and Kilp H. Munich: J.F. Bergmann-Verlag, pp 111–118
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Schmidt, J.G.H., Mansfeld-Nies, R. & Nies, C. On the recovery of the electroretinogram after removal of intravitreal copper particles. Doc Ophthalmol 65, 135–142 (1987). https://doi.org/10.1007/BF00162728