Skip to main content
Log in

Advances in the monitoring of oral anticoagulation: Point-of-care testing, patient self-monitoring, and patient self-management

  • Clinical Investigation and Epidemiology
  • Published:
Journal of Thrombosis and Thrombolysis Aims and scope Submit manuscript

Abstract

Oral anticoagulation with warfarin sodium has proven to be an effective therapy for patients at risk for thromboembolic disease, but due to its high risk/benefit ratio, many physicians are reluctant to prescribe the drug. The development of capillary whole-blood prothrombin time (PT) monitors provides a potential means to decrease this risk/benefit ratio and to encourage the use of warfarin. Studies show that this technology is accurate, precise, and correlates closely with standard laboratory methods. Given that these monitors are simple and portable, investigators have conducted studies to determine their suitability for patient self-testing and home monitoring. Investigations show that patients can accurately and precisely perform the PT test at home, and that this mode of therapy appears to be at least as safe and effective as standard management. Furthermore, limited studies also suggest that patients can also manage their own dosing based on personalized guidelines designed by a physician. Given the theoretical potential for improved patient outcomes and overall cost reduction, patient self-monitoring and self-management are not far off. Large randomized prospective trials are now needed to confirm that the future of anticoagulation management should include patient self-monitoring and patient self-management of therapy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ansell J. Oral anticoagulant therapy: Fifty years later. Arch Intern Med 1993;153:586–596.

    Google Scholar 

  2. Kutner M, Nixon G, Silverstone F. Physicians' attitudes toward oral anticoagulants and antiplatelet agents for stroke prevention in elderly patients with atrial fibrillation. Arch Intern Med 1991;151:1950–1953.

    Google Scholar 

  3. McCrory DC, Matchar DB, Samsa G, Sanders LL, Pritchett ELC. Physician attitudes about anticoagulation for nonvalvular atrial fibrillation in the elderly. Arch Intern Med 1995;155:277–281.

    Google Scholar 

  4. Agency for Health Care Policy Research. Life-saving treatments to prevent stroke underused. Press release, September 7, 1995.

  5. Garabedian-Ruffalo SM, Gray DR, Sax MJ, Ruffalo RL. Retrospective evaluation of a pharmacist-managed warfarin anticoagulation clinic. Am J Hasp Pharm 1985;42:304–308.

    Google Scholar 

  6. Cortelazzo S, Finazzi G, Verio P, Galli M, Remuzzi A, Parenzan L, Barbui T. Thrombotic and hemorrhagic complications in patients with mechanical heart valve prosthesis attending an anticoagulation clinic. Thromb Haemost 1993;69:316–320.

    Google Scholar 

  7. Wilt VM, Gums JG, Ahmed OI, Moore LM. Outcome analysis of a pharmacist-managed anticoagulation service. Pharmacotherapy 1995;15:732–739.

    Google Scholar 

  8. Bussey HL, Chiquette E, Amato MG. Anticoagulation clinic care versus routine medical care: A review and interim report. J Thromb Thrombolys 1996;2:315–319.

    Google Scholar 

  9. Lucas FV, Duncan A, Jay R, et al. A novel whole blood capillary technic for measuring the prothrombin time. Am J Clin Pathol 1987;88:442–446.

    Google Scholar 

  10. Yano Y, Kambayashi J, Murata K, et al. Bedside monitoring of warfarin therapy by a whole blood capillary coagulation monitor. Thromb Res 1992;66:583–590.

    Google Scholar 

  11. Weibert RT, Adler DS. Evaluation of a capillary whole blood prothrombin time measurement system. Clin Pharm 1989;8:864–867.

    Google Scholar 

  12. Jennings I, Luddington RJ, Baglin T. Evaluation of the Ciba Corning Biotrack 512 coagulation monitor for the control of oral anticoagulation. J Clin Pathol 1991;44:950–953.

    Google Scholar 

  13. McCurdy SA, White RH. Accuracy and precision of a portable anticoagulation monitor in a clinical setting. Arch Intern Med 1992;152:589–592.

    Google Scholar 

  14. Tripodi A, Arbini AA, Chantarangkul V, et al. Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the International Normalized Ratio? Thrombo Hemosta 1993;70:921–924.

    Google Scholar 

  15. Oberhardt BJ, Dermott SC, Taylor M, Alkadi ZY, Abruzzini AF, Gresalfi NJ. Dry reagent technology for rapid, convenient measurements of blood coagulation and fibrinolysis. Clin Chem 1991;37:520–526.

    Google Scholar 

  16. Rose VL, Dermott SC, Murray BF, et al. Decentralized testing for prothrombin time and activated partial thromboplastin time using a dry chemistry portable analyzer. Arch Pathol Lab Med 1993;117:611–617.

    Google Scholar 

  17. Fabbrini N, Messmore H, Balbale S, et al. Pilot study to determine use of a TAS analyzer in an anticoagulation clinic setting. Blood 1995;86(Suppl 1):869a.

    Google Scholar 

  18. Tripodi A, Clerici M, Negri B, Chantarangkul V, Mannucci PM. International sensitivity index determination for a new, very sensitive point-of-care testing device to monitor oral anticoagulant therapy. Assessment of adequacy to the recommended WHO model. Blood 1995;86(Suppl 1):890a.

    Google Scholar 

  19. Kaatz AA, White RH, Hill J, et al. Accuracy of laboratory and portable monitor International Normalized Ratio determinations. Arch Intern Med 1995;155:1861–1867.

    Google Scholar 

  20. Ansell J, Becker D, Andrew M, Becker R, Triplett D, Cimini C, LaDuca F. Accurate and precise prothrombin time measurement in a multicenter anticoagulation trial employing patient self-testing. Blood 1995;86(Suppl 1):864a.

    Google Scholar 

  21. Andrew M, Marzinotto V, Adams M, Cimini C, Triplett D, LaDuca F. Monitoring of oral anticoagulant therapy in pediatric patients using a new microsample PT device. Blood 1995:86(Suppl 1):863a.

    Google Scholar 

  22. Belsey RE, Fischer PM, Baer DM. An evaluation of a whole blood prothrombin analyzer designed for use by individuals without formal laboratory training. J Fam Pract 1991;33:266–271.

    Google Scholar 

  23. White RH, McCurdy SA, von Marensdorff H, Woodruff DE, Leftgoff L. Home prothrombin time monitoring after initiation of warfarin therapy. Ann Intern Med 1989;111:730–737.

    Google Scholar 

  24. Anderson D, Harrison L, Hirsh J. Evaluation of a portable prothrombin time monitor for home use by patients who require long-term oral anticoagulant therapy. Arch Intern Med 1993;153:1441–1447.

    Google Scholar 

  25. Erdman S, Vidne B, Levy MJ. A self-control method for long-term anticoagulation therapy. J Cardiovasc Surg 1974;15:454–457.

    Google Scholar 

  26. Schachner A, Deviri E, Shabat S. In: Butchart EG, Bodnar E, eds. Patient-regulated anticoagulation. Thrombosis, Embolism, and Bleeding. London: ICR Publishers, 1992:318–324.

    Google Scholar 

  27. Ansell J, Holden A, Knapic N. Patient self-management of oral anticoagulation guided by capillary (fingerstick) whole blood prothrombin times. Arch Intern Med 1989;149:2509–2511.

    Google Scholar 

  28. Ansell J, Patel N, Ostrovsky D, Nozzolillo E, Peterson AM, Fish L. Long-term patient self-management of oral anticoagulation. Arch Intern Med 1995;155:2185–2189.

    Google Scholar 

  29. Bernardo A. Experience with patient self-management of oral anticoagulation. J Thromb Thrombolys 1996;2:321–325.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Leaning, K.E., Ansell, J.E. Advances in the monitoring of oral anticoagulation: Point-of-care testing, patient self-monitoring, and patient self-management. J Thromb Thrombol 3, 377–383 (1996). https://doi.org/10.1007/BF00133081

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00133081

Key Words

Navigation