The effect of the bead diameter on the accuracy of two techniques used in bone ingrowth quantification, microradiography and backscattered electron imaging-scanning electron microscopy (BEI-SEM), was assessed using porous-coated implants. Two groups of seven titanium porous implants (group A: bead size 250–350 μm and group B: 500–700 μm) were implanted for 12 weeks in a canine model. After euthanasia, the same histological slides were prepared for microradiography and BEI-SEM. The percentage of bone, bone ingrowth, bone ongrowth, porosity and bone index were determined by a point counting method using images from both techniques. ANOVA and Tukey's test were used to compare the results from the different bead sizes and techniques. The results showed significant higher bone ingrowth in microradiography groups, and significant lower porosity in only the fine-bead microradiography group (group A size). Microradiography also obtained significantly higher bone ongrowth, but only for the coarse bead size group (group B). From these results it was concluded that microradiography decreases the porosity of the porous coating compared with BEI-SEM. This effect seems to be dependent on the bead diameter. The smaller the diameter, the greater the effect. Furthermore, microradiography increases bone ingrowth which seems to be affected independently of the bead diameter, becoming the most sensitive parameter to increase.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. O. GALANTE, W. ROSTOKER, R. LUECK and R. D. RAY, J. Bone Joint Surg. A 53 (1971) 61.

    Google Scholar 

  2. R. M. PILLIAR, H. U. CAMERON and I. MACNAB, J. Biomed. Engng. 10 (1975) 126.

    Google Scholar 

  3. R. D. BLOEBAUM, S. A. REID and K. N. BACHUS, in Proceedings of 35th Annual Meeting of the Orthopedic Research Society (ORS, Las Vegas, 1989) p. 399.

    Google Scholar 

  4. D. R. SUMNER, J. M. BRYAN, R. M. URBAN and J. R. KUSZAK, J. Orthop. Res. 8 (1990) 448.

    Google Scholar 

  5. R. E. HOLMES, H. K. HAGLER and C. A. COLETTA, J. Biomed. Mater. Res. 21 (1987) 731.

    Google Scholar 

  6. J. JOWSEY, P. J. KELLY, L.B. RIGGS, A. J. BIANCO, D. A. SCHOLZ and J. GERSHON-COHEN, J. Bone Joint Surg. A. 47 (1965) 785.

    Google Scholar 

  7. D. B. KIMMEL and S. S. J. WEBSTER, in “Bone histomorphometry techniques and interpreation”, edited by R. R. RECKER (CRC Press, Boca Raton, 1983), p. 89.

    Google Scholar 

  8. M. JASTY, C. R. BRAGDON, S. SCHUTZER, H. RUBASH, T. HAIRE and W. H. HARRIS. Scan. Microscopy, 3 (1989) 1051.

    Google Scholar 

  9. A. M. PARFITT, M. K. DREZNER, F. H. GLORIEUX, J. A. KANIS, H. MALLUCHE, P. J. MEUNIER, S. M. OTT and R. R. RECKER, J. Bone Min. Res. 2 (1987) 595.

    Google Scholar 

  10. K. N. BACHUS, A. A. HOFMANN and L. A. DAUTERMAN, in Proceedings of 34th Annual Meeting of the Orthopedic Research Society (ORS, Atlanta, 1988), p. 308.

    Google Scholar 

  11. T. ALBREKTSSON, P. I. BRANEMARK, H. A. HANSSON and J. LINDSTROM, Acta Orthop. Scand. 52 (1981) 155.

    Google Scholar 

  12. A. H. HOLMES, in “Petrographic methods and calculations” (Murby & Co., London, 1927).

    Google Scholar 

  13. R. T. DEHOFF and F. N. RHINES, in “Quantitative microscopy” (McGraw-Hill, New York, 1968).

    Google Scholar 

  14. E. E. UNDERWOOD, in “Quantitative stereology” (Addison-Wesley, Reading, MA, 1970).

    Google Scholar 

  15. E. R. WEIBEL, in “Stereological methods” (Academic Press, San Diego, 1979), p. 139.

    Google Scholar 

  16. W. J. WHITHEHOUSE, J. Microcopy 107 (1976) 183.

    Google Scholar 

  17. A. MORONI, V. CAJA, E. EGGER, F. GOTTSAUNERWOLF, L. TRINCHESE, G. ROLLO and E. Y. CHAO, in “Bioceramics. Materials, properties, applications” edited by A. RAVAGLIOLI and A. KRAJEWSKY (Chapman & Hall, New York, 1991), p. 141.

    Google Scholar 

  18. R. D. BLOEBAUM, T. A. GRUEN, P. CAMPBELL and L. D. DORR, in Proceedings of 34th Annual Meeting of the Orthopedic Research Society (ORS, Atlanta, 1988) p. 366.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Caja, V.L., Moroni, A., Egger, E.L. et al. The effect of bead diameter on the accuracy of two current techniques used to quantify bone ingrowth in porous-coated implants. J Mater Sci: Mater Med 5, 29–32 (1994). https://doi.org/10.1007/BF00121150

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00121150

Keywords

Navigation