Abstract
Simultaneous and sequential tests of pump sampling equipment showed that sampling mortality of Lake Michigan zooplankton collected from the cooling water intake of a nuclear power plant was dependent on the sampling method used. Two sampling devices and two pump types were tested to determine which combination resulted in the lowest sampling mortality. An in-line filter trap located on the suction side of the pump provided the lowest sampling mortality. Higher sampling rates were achieved with a centrifugal pump without increasing sampling mortality.
Similar content being viewed by others
References
Aron, W. 1968. The use of a large capacity portable pump for planktonic sampling, with notes on planktonic patchiness. J. Mar. Res. 16: 158–173.
Beers, J. R., Stewart, G. L. & Strickland, J. D. H. 1967. A pumping system for sampling small zooplankton. J. Fish. Res. Bd. Canada 24: 1811–1817.
Icanberry, J. W. & Richardson, R. W. 1973. Quantitative sampling of live zooplankton with a filter pump system. Limnol. Oceanogr. 18: 333–335.
Jensen, L. D. 1974. Environmental Responses to Thermal Discharges from the James River, Virginia. Report 13, Cooling Water Discharge Project (RP-49). Prepared for the Electric Power Research Institute and the Virginia Electric and Power Co.
Leong, R. 1967. Evaluation of a pump and reeled hose system for studying the vertical distribution of small plankton. U.S. Fish. Wildl. Serv. Sci. Rep., Fish. 545, 19 P.
O'Connell, C. P. & Leong, R. J. H. 1963. A towed pump and shipboard filtering system for sampling small zooplankton. U.S. Fish. Wildl. Ser. Sp. Rep. Fish. 452, 19 P.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Yocum, W.L., Evans, M.S. & Hawkins, B.E. A comparison of pump sampling systems for live zooplankton collection. Hydrobiologia 60, 199–202 (1978). https://doi.org/10.1007/BF00011713
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF00011713