A practical technique to measure transformer losses in high frequency SMPS
Abstract
All electronic gadgets today employ high frequency Switch Mode Power Supplies. As the number of such gadgets is increasing rapidly, the focus is on improving the efficiency of power conversion and better utilization of energy. It is always a challenge for the practicing power supply engineers to exactly apportion and evaluate the total losses in the power converters. While it is relatively easy to compute and measure the power losses in semiconductor devices, it is practically difficult to measure the power losses in magnetic components. The data sheets provided by the manufacturers, for core loss and thermal resistance, do act as a starting point in the design stage but, always the designers felt the need to know the exact power loss in the ferrite high frequency transformers and their thermal resistance values. The data sheets provide thermal resistance values only for the cores and it is necessary to quantify value for a fully wound transformers. Copper losses in high frequency transformers are very significant and too involved to compute. In this paper, we propose a simple and practical technique, which precisely depicts the actual power loss in a high frequency ferrite core transformer. With this technique various ferrite cores can be characterized for their hysteresis losses at varying flux densities and frequencies. We can also precisely compute the thermal resistance of the Ferrite transformers.
Keywords
High frequency transformer Ferrite core loss Measurement of losses SMPS Practical power supply design1 Introduction
Electronics has become an indispensable part of all facets of human life. Entertainment, communication, lighting, health care, information, transport etc. are all invariably linked to utilizing electrical energy. However, the electric supply from the utility grid is in the form of AC and the electrical gadgets need a stable DC supply for their operation. This calls for power supplies which take AC and convert to a stable DC power to the target equipment [1].
In view of the product design requirements, compactness, in terms of size and volume also has become a major specification in the product. This has necessitated the adoption of switch mode power converters which operate at high frequencies [2].
A general purpose AC to DC switch mode converter is detailed below.
AC–DC converter has in its front end a typical full bridge rectifier, which converts the incoming AC mains voltage into a unidirectional time varying voltage at twice the mains frequency. This is followed up by a large high voltage bulk reservoir capacitor which filters out the time varying voltage to an unregulated steady DC voltage. Typically, for an input AC voltage of 230 V AC, the rectified DC voltage at the reservoir capacitor would be about 325 V DC. However, this voltage has some ripple content, based on the reservoir capacitor value and the load current drawn from this source. In addition, the DC voltage would be unregulated and varies with mains voltage. For an input voltage range of 180 V AC to 264 V AC, The DC voltage can be in the range of 225 V DC to 390 V DC. The power converter is supposed to handle this large input DC voltage variation and deliver a rock steady DC output voltage in the range of say 5 V DC, or 12 V or 24 V or 48 V as needed by the end equipment and also should provide galvanic isolation from the input mains supply for safety and EMI/EMC related issues [3].
As a next step, the unregulated DC voltage is connected to a transformer with a ferrite core and a semiconductor switch, either a power transistor or a power MOSFET. The transformer would be capable of operating at high frequencies (around 100’s of kHz) and the semiconductor switch is driven ON and OFF at high frequency. Thus, the circuit acts as a chopper at high frequency and the transformer sees a high frequency AC voltage. Secondary of the transformer, which is electrically isolated from the primary, is rectified with fast recovery rectifier diodes and then connected to a low pass filter comprising of a ferrite core inductor and electrolytic capacitors. Output of the low pass filter is a DC voltage which can be regulated to a precise value, by controlling the ON or OFF time of the semiconductor power switch [3].
A stable reference, high gain error amplifier, sampled output voltage together generate an error voltage which controls the ON or OFF time of the power switch and is transferred to power switch with a galvanic isolated drive. Thus, the AC DC converter delivers a stable lower DC voltage to the end appliance with total isolation from the high voltage utility mains [3].
2 Problem statement
As discussed earlier, automation has created a sudden demand for the power converters and also for the electrical energy. However, the generation of electricity which is predominantly by fossil fuels has impact on the environment [1]. Hence, the focus is on improving the energy efficiency of electronic gadgets so that the available resources are best utilized. The importance of discussion on the power losses and especially in transformers can be well appreciated by referring to [4, 5], as it discusses the power loss in an electronic power transformer as against a conventional power transformer.
Having said about the efficiency improvement, the first element in the chain of a product is the power converter sitting right at the front end and it would be critically looked at for efficiency improvement. Front end converter handles the complete power requirement of the electrical gadget and therefore needs to be highly efficient.
- (a)
The input rectifier bridge,
- (b)
The high frequency power transformer,
- (c)
Power MOSFET,
- (d)
Output filter inductor,
- (e)
Output rectifier diodes.
Miscellaneous losses such as in the bias circuits, housekeeping circuits, filter capacitors, PCB track losses etc. can be neglected as they form a small percentage of loss and their improvement may not add much to the target. Among them the losses in the semiconductor devices are primarily computable, with the available math equations [6].They can be easily verified also, by mounting them on heat sinks which are pre calibrated for their thermal resistance Rth. Thermal resistance is defined as the temperature rise above ambient for every watt of power dissipated and has the units °C/watt [7]. By mounting the semiconductors on the heat sinks with known Rth and measuring the temperature rise of the heat sink directly measures the power loss in the device.
The power loss measurement of the ferrite transformers/inductors is not that simple [8, 9, 10]. Thermal resistance of the cores as depicted from the data sheet cannot be adopted as it is. Data sheets provide thermal resistance for only the core and not for the complete transformer [11, 12]. A wound transformer has a different property altogether.
- (a)
Core loss or hysteresis loss and
- (b)
Copper losses in the winding.
Both losses are very complicated, non-linear in nature and too involved to theoretically compute [13]. Core loss depends on the frequency of operation, flux swing, geometry of the core and also the grade of ferrite. Likewise copper losses depend on Skin effect, proximity effect, type of topology of converter and the construction of the transformer layers [14].
Therefore, it is matters of importance to at least quantify the exact amount of core loss in ferrite transformer and also characterize the thermal resistance of the transformer. With this, half of the total transformer loss can be precisely estimated. If the accurate thermal resistance value can be obtained for the transformer, then we can also indirectly compute the copper loss.
We propose in this paper a technique to precisely measure the core loss in the designed transformer and also estimate the thermal resistance of the transformer. With these two, exact losses in the transformer can be measured.
Further, this technique can also be used to create a data base for the core losses in various cores at different frequencies and a variety of flux density swings.
3 Methodology
The proposed methodology is very simple and easily implemented in the real life applications.
Hysteresis losses of a ferrite core are due to the work done during every switching cycle in magnetizing and demagnetizing the core. The same is well discussed widely under the heading called B-H curve [15]. Core losses depend on frequency of operation, flux density swing, core volume and core material grade. Lot of literature is available from the manufacturers’ data sheets.
When any transformer primary is excited with alternating current (AC) voltage and the secondary is left unconnected, then the current drawn from the primary source voltage indicates the core loss. This is very simple in case of low frequency (50 Hz) transformer with sinusoidal voltage input. Whereas, in high frequency applications with non sinusoidal input voltage and varying ON and OFF times, the measurement of core loss is not that simple. Therefore a simple technique to measure the core loss in a high frequency transformer with non sinusoidal excitation and varying ON or OFF times is essential in practical applications. The following methodology suggests a solution for the above problem. Most important of this technique is that the actual core loss is obtained in the in sit u conditions for the exact field conditions.
Setup for measurement of core loss
- (a)
The designed power converter unit is powered ON at a nominal load at the output and with a stable DC input voltage.
- (b)
Input DC current and DC voltage is recorded. The unit is kept switched ON for about 30 min to stabilize all the parameters. Input power is also recorded and so also the output power.
- (c)
DUT, exactly similar to the one used in the power converter is wound and kept ready.
- (d)
Now, the power converter is switched OFF and the primary of the DUT transformer is connected in parallel to the working unit, with all secondaries of DUT left unconnected.
- (e)
The unit is powered ON again with exactly same input and output conditions as in step (a).
- (f)
After a warm up of about 30 min, again the input voltage and input current are recorded. There would be increase in the input current, and hence the input power now, for the same output power.
- (g)
The increment in the input power is entirely due to the core loss of the DUT transformer. This is noted as the core loss for the given switching frequency and the flux density swing determined by the ON time of the switches S1 to S4.
- (h)
The flux swing in DUT is easily computed by monitoring the voltage impinged across the primary of the DUT transformer (which is same for the working unit also) and recording the time duration.
- (i)We know the core cross section area and hence we can easily arrive at the flux density swing, because we know, voltage across the transformer, its primary turns and also the core area and the time duration for which the voltage is applied. The typical waveform across the DUT is shown in Fig. 2 and the test set up in Fig. 3Fig. 2
Waveform across DUT
Fig. 3Core loss measurement setup
- (j)
Thus, for a given transformer, the core losses are estimated in situ.
- (k)
The DUT is kept ON in the above condition, till the thermal equilibrium is reached and then the temperature of the DUT is recorded.
- (l)
Since we know the power dissipated in DUT as per step (g), and also the rise in temperature of DUT above ambient, the accurate Rth of the DUT is also arrived at.
4 Discussion
Calculation of the power loss in a high frequency transformer is very involved and a lot of study has been done and reported [8, 16]. For a normal practicing power supply manufacturers and engineers, the theoretical part appears to be too complicated to follow. However, it is very important to know the actual losses in all the power components of a converter, in order to improve the product performance, reliability and product design. Therefore a practical technique to assess the losses in magnetic components is well appreciated and need of the hour.
Since the core losses are non-linearly related to flux swing and frequency of operation, it is in the best interest that the power converter chosen is of variable frequency type. This greatly simplifies in evaluating the core loss at different frequencies and different Flux density levels.
Losses for EE25 double stack transformer at various flux densities and frequencies
EE 25 double stack N87 | ||
---|---|---|
ΔB (mT) | Frequency (kHz) | Loss (mW) |
100 | 100 | 360 |
200 | 100 | 1350 |
400 | 100 | 4830 |
100 | 200 | 600 |
200 | 200 | 1800 |
400 | 200 | 8100 |
Losses for EE42 single stack transformer at various flux densities and frequencies
EE 42 single stack N87 | ||
---|---|---|
ΔB (mT) | Frequency (kHz) | Loss (mW) |
100 | 100 | 772 |
200 | 100 | 3280 |
320 | 100 | 6800 |
100 | 200 | 900 |
200 | 200 | 4500 |
450 | 200 | 17,000 |
5 Experimental verification and validation
In order to demonstrate the efficacy and usefulness of the scheme proposed, a practical fly back converter of 150 W was designed, fabricated and evaluated to accurately assess the power loss in the power transformer.
150 W flyback converter block diagram
150 W flyback converter
Specifically, the soft switching converter with BCM controller is chosen, so as to minimize all the losses which makes it easy to concentrate on the transformer loss alone.
- (a)
Input bridge rectifier,
- (b)
MOSFET switch,
- (c)
Output rectifier, and
- (d)
The main power transformer.
Bias and drive losses are catered to by a separate bias supply. Such a unit was designed and fabricated and tested. The test data such as input power, output power is recorded for a stable DC input voltage. With this data, total losses were arrived at.
- 1.
INPUT voltage: 190 V DC
- 2.
OUTPUT voltage: 150 V DC
- 3.
Output current: 1.0 A
- 4.
Switching Frequency anticipated to be around 150 kHz (Since the BCM flyback is a variable frequency converter)
- 5.
Configuration: soft switching BCM
- (a)
Core: ferrite EE25/13/7 double stack
- (b)
Material: N87
- (c)
Primary inductance Lp = 100 micro henries
- (d)
Primary turns Np = 20
- (e)
Primary wire size = 34SWG, 6wires twisted and bundled
- (f)
Secondary inductance Ls = 59 micro henries
- (g)
Secondary turns Ns = 15
- (h)
Secondary wire size: 34SWG, 4 wires twisted and bundled
- (i)
Leakage inductance Ll = 1.9 micro henries
- (j)
Primary DC resistance Rp = 80 mOhms
- (k)
Secondary DC resistance Rs = 90 mOhms
In order to evaluate the exact core losses in the above transformer, a 250 W bridge converter is built to operate at 175 kHz. Input voltage and output load were adjusted to obtain 150 V DC bipolar and for 2.5 ms to be impinged across the transformer. Next, an Identical transformer as the one used in the flyback converter is fabricated and the secondary consisting of 15 turns, is connected in parallel to the main transformer of the half bridge converter. The primary of the flyback transformer with 20 turns was left open. With this condition the half bridge converter was run for about 4 h to attain thermal equilibrium.
Under this condition, the observed increment in the input power of the half bridge converter is noted to be 1.75 W. This is the core loss in the fly back transformer at 175 kHz and 250 mT flux swing.
Simultaneously, the rise in the flyback transformer temperature was recorded as 32 °C above ambient.
The Flyback converter with designed transformer is then run at 150 W load continuously till thermal equilibrium and temperature rise of transformer is recorded. The obtained switching frequency was 175 kHz.
- 1.
Frequency of operation: 175 kHz
- 2.
MOSFET ON time Ton obtained: 2.0 ms
- 3.
Ds Secondary diode ON time Dson: 2.5 ms
- 4.
Delay time Td: 1.2 ms
- 5.
Time period T = Ton +Td +Dson = 5.7 ms
- 6.
Duty cycle D = Ton/T = 0.351
- 7.
Ds ON duty ratio = 0.439
- 8.
Input voltage = 190 V DC
- 9.
Input current Iindc = 0.846 A
- 10.
Output voltage = 151.2 V DC
- 11.
Output current = 1.0 A
- 12.
Total losses recorded = 9.54 W (input power–output power)
- 13.
The computed flux density swing in the practical converter is 250 mT
Temperature rise of the flyback transformer after thermal stabilization = 68 °C above ambient.
The input bridge rectifier loss is measured to be 1.3 W.
The current sense resistor and the output sense network together consumed about 1.3 W.
With this the total losses measured in the converter of 150 W are 6.1 W, not accounting for transformer. The total converter losses are noted to be 9.54 W. Hence, from this angle; the estimated power loss in transformer is 9.54 − 6.1 = 3.44 W. However, the power loss computed from the proposed scheme by measuring the temperature rise and Rth is 3.72 W which is in close acceptance range. Thus, the proposed method of core loss measurement is validated in a practical set up
6 Conclusions
Measuring the power loss in a high frequency ferrite transformer is very essential for all power supply engineers. Improving the efficiency of the converter can be done, only if the losses occurring at various levels are known. Therefore, any effort in contributing to the loss estimation is a welcome phenomenon and this paper proposes a simple, implementable technique to practically estimate the losses in high frequency transformers.
Core loss data for two types of cores are measured and presented. Thermal resistance derived practically is also depicted. A practical 150 W flyback converter is built and evaluated for its losses and verified with the proposed technique. Quantum of increased copper loss due to skin and proximity effects is clearly arrived at.
The proposed scheme accurately arrives at the losses in a high frequency power transformer. This enables designers to try out various design options and arrive at an optimum configuration for maximizing the efficiency. The designed 150 W fly back converter achieved an efficiency of 94.06%.
Notes
Compliance with ethical standards
Conflict of interest
The authors declare that they have no conflict of interest.
Human and animal rights
There is no involving human participants and/or animals in this research work.
References
- 1.Global Energy Transformation (2018) A road map to 2050, IRENAGoogle Scholar
- 2.World Energy Council (2013) World energy perspectiveGoogle Scholar
- 3.On Semiconductors (2014) Switch mode power supply—reference manualGoogle Scholar
- 4.Yue Q, Li C et al (2018) Comprehensive power losses model for electronic power transformer. IEEE Access 6:14926–14934CrossRefGoogle Scholar
- 5.Yue S et al (2017) Core loss calculation of the soft ferrite cores in high frequency transformer under non-sinusoidal excitations. In: 20th international conference on electrical machines and systems (ICEMS)Google Scholar
- 6.Tektronix (2011) Power supply measurement and analysisGoogle Scholar
- 7.Orenchak G (2004) Estimating temperature rise of transformers. Power Electron MagGoogle Scholar
- 8.Jamerson C (2002) Targeting switcher magnetics core loss calculations. Power Electron Technol 28(2):14–25Google Scholar
- 9.Muhlethaler J, Biela J, Kolar JW et al (2012) Improved core-loss calculation for magnetic components employed in power electronic systems. IEEE Trans Power Electron 27(2):964–973CrossRefGoogle Scholar
- 10.Application note, switchmode power supply transformer design, West Coast Magnetics, www.wcmagnetics.com 1.800.628.1123. Accessed 2 Jan 2019
- 11.Magnetic Materials Producers Association (1998) Soft ferrites a user’s guide, MMPA SFG98, 1998Google Scholar
- 12.Magnetics Inc (2017) Magnetics ferrite cores catalogueGoogle Scholar
- 13.McLyman CWT (1978) Transformer and inductor design handbook. Marcel Dekker Inc., New YorkGoogle Scholar
- 14.Carsten B (1986) High frequency conductor losses in switch mode magnetics. PCIMGoogle Scholar
- 15.Ridley R (2016) Magnetic core loss, APEC industry session on magneticsGoogle Scholar
- 16.Orenchak G Predicting temperature rise of ferrite cored transformers. TSC Ferrite International. http://tscinternational.com/predicttemprise.ppt&ved=2ahUKEwivm-mrkLPgAhVLPY8KHeeVBwUFQFjACegQlahAB&usg=AOvVaw1RtnWuj7TyBH9RrqKowJOX. Accessed 2 Jan 2019
- 17.Pressman AI, Billings K, Morey T (2009) Switching power supply design, 3rd edn. McGraw Hill, New YorkGoogle Scholar
- 18.Mannam R, Gorantla S R, Vangala N (2017) Soft switching flyback converter adopting fixed dead time. JARDECS 9(1):221–234Google Scholar