Radiation protection in the design of γ-ray industrial computed tomography systems
- 35 Downloads
Abstract
The recent increasing use of γ-ray industrial computed tomography (γ-ray ICT) in various fields has induced greater attention to its performance as well as to considerations of radiation safety. It is understood that radiation protection planning cannot be sacrificed for the sake of CT image quality during the design, manufacture, and layout of γ-ray ICT systems. In the present work, we describe a typical γ-ray ICT system in brief, and, based on experience and pertinent examples, we propose design requirements for ensuring the radiation safety of the sealed radioactive source, source container, and workspace. The design examples and dose rate measurement results illustrate that the proposed design standards are reasonable, feasible, and safe, and are therefore meaningful for the design, manufacture, and layout of γ-ray ICT systems. This paper discussed the predominant measures associated with the radiation protection of γ-ray ICT systems in accordance with the pertinent Chinese standards. In addition, based on experience and pertinent examples, the design requirements for ensuring the radiation safety of a sealed radioactive source, source container, and workspace were defined in detail. The design examples and dose rate measurements conducted in conjunction with a γ-ray ICT system and workspace employing the proposed design standards have illustrated that the proposals provided in this paper are reasonable, feasible, and safe, and are therefore meaningful for the design, manufacture, and layout of γ-ray ICT systems.
Keywords
γ-ray industrial computed tomography Radiological protection Sealed radioactive sources Source containerReferences
- 1.M. Chang, Y.-S. Xiao, Z.-Q. Chen, An industrial CT system for monitoring a running aero-engine. Nucl. Sci. Tech. 25, 060202 (2014). doi: 10.13538/j.1001-8042/nst.25.060202 Google Scholar
- 2.C.Z. Zhang, Effect of technical data of an industrial CT on its performance: a guide for industrial CT system selection. Non Destr. Test. NDT 29, 48–61 (2007)Google Scholar
- 3.R. Tschentscher, M. Schubert, A. Bieberle et al., Tomography measurements of gas holdup in rotating foam reactors with Newtonian, non-Newtonian and foaming liquids. Chem. Eng. Sci. 66, 3317–3327 (2011). doi: 10.1016/j.ces.2011.01.051 CrossRefGoogle Scholar
- 4.S. Izumi, S. Kamata, K. Satoh et al., High energy X-ray computed tomography for industrial applications. IEEE Trans. Nucl. Sci. 40, 158–161 (1993). doi: 10.1109/23.212333 CrossRefGoogle Scholar
- 5.A. Bieberle, H. Nehring, R. Berger et al., Compact high-resolution gamma-ray computed tomography system for multiphase flow studies. Rev. Sci. Instrum. 84, 033106 (2013). doi: 10.1063/1.4795424 CrossRefGoogle Scholar
- 6.A. Bieberle, D. Hoppe, E. Schleicher et al., Void measurement using high-resolution gamma-ray computed tomography. Nucl. Eng. Des. 241, 2086–2092 (2011). doi: 10.1016/j.nucengdes.2011.03.028 CrossRefGoogle Scholar
- 7.U. Hampel, H.V. Hristov, A. Bieberle et al., Application of high resolution gamma ray tomography to the measurement of gas hold-up distributions in a stirred chemical reactor. Flow Meas. Instrum. 18, 184–190 (2007). doi: 10.1016/j.flowmeasinst.2007.06.001 CrossRefGoogle Scholar
- 8.A.C. De Vuono, P.A. Schlosser, F.A. Kulacki et al., Design of an isotopic CT scanner for two-phase flow measurements. IEEE Trans. Nucl. Sci. 27, 814–820 (1980). doi: 10.1109/TNS.1980.4330933 CrossRefGoogle Scholar
- 9.A. Bieberle, R. Berger, R. Yadav et al., Design of a modular signal processing board (MSPB) for gamma-ray imaging applications. Nucl. Instrum. Methods Phys. Res. A 663, 14–21 (2012). doi: 10.1016/j.nima.2011.09.060 CrossRefGoogle Scholar
- 10.H. Gao, L. Zhang, Z. Chen et al., Beam hardening correction for middle-energy industrial computerized tomography. IEEE Trans. Nucl. Sci. 53, 2796–2806 (2006). doi: 10.1109/TNS.2006.879825 CrossRefGoogle Scholar
- 11.U. Hampel, D. Hoppe, A. Bieberle et al., Measurement of fluid distributions in a rotating fluid coupling using high resolution gamma ray tomography. Fluids Eng. 130, 091402 (2008). doi: 10.1115/1.2953295 CrossRefGoogle Scholar
- 12.A. Bieberle, J. Kronenberg, E. Schleicher et al., Design of a high-resolution gamma ray detector module for tomography applications. Nucl. Instrum. Methods Phys. Res. A 572, 668–675 (2007). doi: 10.1016/j.nima.2006.12.034 CrossRefGoogle Scholar
- 13.International Atomic Energy Agency. Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards. Vienna. No. GSR Part 3. (2011)Google Scholar
- 14.GBZ175-2006. Standards for radiation protection of γ-ray industrial computed tomography. National Standards. Beijing, China. (2006)Google Scholar
- 15.O. Ciraj-Bjelac, D. Arandjic, D. Kosutic, Comparison of different methods for shielding design in computed tomography. Radiat. Prot. Dosimetry. 147, 133–136 (2011). doi: 10.1093/rpd/ncr287 CrossRefGoogle Scholar
- 16.International Atomic Energy Agency. Revised Categorization of Radioactive Sources. Vienna. IAEA-TECDOC-1344. (2003)Google Scholar
- 17.International Atomic Energy Agency. Radiation protection in the Design of Radiotherapy Facilities. Vienna. Safety Reports Series No. 47. (2006)Google Scholar
- 18.International Atomic Energy Agency. Industrial Process Gamma Tomography. Vienna. IAEA-TECDOC-1589. (2008)Google Scholar
- 19.S.G. Langer, J.E. Gray, Radiation shielding implications of computed tomography scatter exposure to the floor. Health Phys. 75, 193–196 (1988). doi: 10.1097/00004032-199808000-00012 CrossRefGoogle Scholar
- 20.National Council on Radiation Protection and Measurements. Structural Shielding Design and Evaluation for Medical Use of X Rays and Gamma Rays of Energies Up to 10 MeV. Bethesda, Maryland, US, NCRP Report No. 49 (1976)Google Scholar
- 21.D.J. Simpkin, A general solution to the shielding of medical x and γ rays by the NCRP Report No. 49 methods. Health Phys. 52, 431–436 (1987). doi: 10.1097/00004032-198704000-00003 CrossRefGoogle Scholar
- 22.GB18871-2002. Basic standards for protection against ionizing radiation and for the safety of radiation sources. National Standards. Beijing, China. (2002)Google Scholar
- 23.National Council on Radiation Protection and Measurements. Recent Applications of the NCRP Public Dose Limit Recommendation for Ionizing Radiation, Washington, DC, US. Statement No. 10. (2004)Google Scholar