Advertisement

An Experimental Investigation into Fiber/Textile-Reinforced Lightweight Concrete Precast Panels for Temporary Housing

  • Hamid NaseriEmail author
  • Masood Danesh
  • Mikaiel Naseri
Research Paper

Abstract

Fiber/textile-reinforced lightweight concrete (F/TRLWC) can be used as an excellent building material for the structural/nonstructural elements due to its high flexural strength and low density with respect to the plain concrete. In this paper, eighteen panel specimens with different fiber/textile are subjected to three-point bending test to study the mechanical properties including flexural behavior, energy absorption, and ductility. The applications of these panels for use as wall or roof are also investigated. According to the results, F/TRLWC precast panels have sufficient energy absorption, flexural strength, and suitable ductility. Due to the appropriate characteristics, these panels can be used in constructing temporary precast houses.

Keywords

Concrete Lightweight Fibers/textile Precast panel Temporary housing 

References

  1. ACI 318–11 (2001) Institute building code requirements for structural concrete. American Concrete Institute, Farmington HillsGoogle Scholar
  2. ACI 440.1R-06 (2006) Guide for the design and construction of structural concrete reinforced with FRP. American Concrete Institute, Farmington HillsGoogle Scholar
  3. Arisoy B, Wu HC (2008) Material characteristics of high performance lightweight concrete reinforced with PVA. Constr Build Mater 22(4):635–645CrossRefGoogle Scholar
  4. Balendran RV, Zhou FP, Nadeem A, Leung AYT (2002) Influence of steel fibres on strength and ductility of normal and lightweight high strength concrete. Build Environ 37(12):1361–1367CrossRefGoogle Scholar
  5. Barnett SJ, Lataste JF, Parry T, Millard SG, Soutsos MN (2010) Assessment of fibre orientation in ultra-high performance fibre reinforced concrete and its effect on flexural strength. Mater Struct 43(7):1009–1023CrossRefGoogle Scholar
  6. Behnia A et al (2016) Failure prediction and reliability analysis of ferrocement composite structures by incorporating machine learning into acoustic emission monitoring technique. Constr Build Mater 120:823–832CrossRefGoogle Scholar
  7. Butler M, Mechtcherine V, Hempel S (2009) Experimental investigations on the durability of fibre–matrix interfaces in textile-reinforced concrete. Cem Concr Compos 31(4):221–231CrossRefGoogle Scholar
  8. Chen B, Liu J (2005) Contribution of hybrid fibers on the properties of the high-strength LWC having good workability. Cem Concr Res 35(5):913–917CrossRefGoogle Scholar
  9. Felice GD, Giannini R (2001) Out-of-plane seismic resistance of masonry walls. J Earthq Eng 5(02):253–271Google Scholar
  10. Gao J, Sun W (1997) Mechanical properties of steel fiber-reinforced, high-strength, LWC. Cem Concr Res 19(4):307–313CrossRefGoogle Scholar
  11. Kim Y-J, Hu J, Lee S-J, You B-H (2010) Mechanical properties of fiber reinforced lightweight concrete containing surfactant. Adv Civil Eng 2010:549642.  https://doi.org/10.1155/2010/549642 CrossRefGoogle Scholar
  12. Kwon S, Nishiwaki T, Kikuta T, Mihashi H (2015) Material design methods for lightweight cement-based composites and its application. J Adv Concr Technol 13(3):178–186CrossRefGoogle Scholar
  13. Liu R, Pantelides CP (2013) Shear strength of GFRP reinforced precast lightweight concrete panels. Constr Build Mater 48:51–58CrossRefGoogle Scholar
  14. Merikallio T, Mannonen R, Penttala V (1996) Drying of LWC produced from crushed expanded clay aggregate. Cem Concr Res 26(11):1423–1433CrossRefGoogle Scholar
  15. Mohammadi Ghazimahalleh M (2008) Out of plane strength of infill panels. In: International conference on earthquake engineering, Beijing, ChinaGoogle Scholar
  16. Nishiwaki T, Koda M, Yamada M, Mihashi H, Kikuta T (2012) Experimental study on self-healing capability of FRCC using different types of synthetic fibers. J Adv Concr Technol 10(6):195–206CrossRefGoogle Scholar
  17. Ranjbar N et al (2016a) A comprehensive study of the polypropylene fiber reinforced fly ash based geopolymer. PLoS ONE.  https://doi.org/10.1371/journal.pone.0147546 Google Scholar
  18. Ranjbar N et al (2016b) High tensile strength fly ash based geopolymer composite using copper coated micro steel fiber. Constr Build Mater 112(2016):629–638CrossRefGoogle Scholar
  19. Reinhardt HW, Krüger M, Große CU (2003) Concrete prestressed with textile fabric. J Adv Concr Technol 1(3):231–239CrossRefGoogle Scholar
  20. Seijo F (2001) Building pressure tests of fiber-reinforced foam-based LWC precast wall panels. Thesis Master of science. Department of Civil Engineering, Texas UniversityGoogle Scholar
  21. Shannag MJ (2011) Characteristics of lightweight concrete containing mineral admixtures. Constr Build Mater 25(2):658–662CrossRefGoogle Scholar
  22. Sukontasukkul P (2009) Use of crumb rubber to improve thermal and sound properties of pre-cast concrete panel. Constr Build Mater 23(2):1084–1092CrossRefGoogle Scholar
  23. Wasseman R, Bentur A (1997) Effect of lightweight fly ash aggregate microstructure on the strength of concrete. Cem Concr Res 27(4):525–537CrossRefGoogle Scholar

Copyright information

© Shiraz University 2019

Authors and Affiliations

  1. 1.Department of Civil EngineeringUrmia UniversityUrmiaIran
  2. 2.Department of Civil EngineeringIslamic Azad University, Salmas BranchUrmiaIran

Personalised recommendations