Adaptive Distance Relaying for Grid-Connected Line with Consideration of Single-Phase Auto-Reclosing

  • Jitendra KumarEmail author
  • Premalata Jena
Research Article - Electrical Engineering
  • 27 Downloads

Abstract

In this paper, the performance of distance relay during single-phase reclosing (SPAR) period is considered. Available distance relaying schemes are affected during SPAR period as the pre-fault signals include both negative- and zero-sequence components. Fault resistance, voltage ratio, load angle, shunt capacitive effect, and other system conditions along with SPAR further make distance estimation erroneous. The proposed adaptive scheme is based on the derivation of the impedance at the relay location using symmetrical component theory. The proposed scheme has been employed to measure the correct value of the fault impedance during SPAR period with variation in different system conditions. This approach also works for without SPAR condition. The performance of the proposed technique is tested using the transient data obtained from the single-circuit line simulated using PSCAD/EMTDC software. Performance of the proposed algorithm is verified using a hardware-in-loop test bed having real-time digital simulator and dSPACE.

Keywords

Single-phase auto-reclosing Adaptive distance protection Faults with high resistance 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Taylor, C.; Mittelstadt, W.A.; Lee, T.N.; Hardy, J.E.; glavitsch, H.; stranne, G.; Hurley, J.D.: Single-pole switching for stability and reliability. IEEE Trans. Power Syst. PWRS 01(2), 25–36 (1986)Google Scholar
  2. 2.
    GE Power Management, Protective Relays: High Voltage Transmission Line Protection with Single Pole Tripping and Reclosing. https://store.gedigitalenergy.com/FAQ/Documents/Alps/GET-6555.pdf.
  3. 3.
    Seyedi, H.; Behroozi, L.: New distance relay compensation algorithm for double-circuit transmission line protection. IET Gener. Transm. Distrib. 5(10), 1011–1018 (2011)CrossRefGoogle Scholar
  4. 4.
    Moravej, Z.; Adelniaa, F.; Abbasi, F.: Optimal coordination of directional overcurrent relays using NSGA-II. Electr. Power Syst. Res. 119, 228–236 (2015)CrossRefGoogle Scholar
  5. 5.
    Thompson, M.J.; Somani, A.: A tutorial on calculating source impedance Ratios for determining line length. In: 68th Annual Conference for Protective Relay Engineers College Station, Texas, pp. 1–9. https://www.selinc.com/WorkArea/DownloadAsset.aspx?id=106181 (2015)
  6. 6.
    Reyna, V.H.S.; Velázquez, J.C.R.; Félix, H.E.P.; Ferrer, H.J.A.; Escobedo, D.S.; Guerrero, J.G.: Transmission Line single-pole tripping: field experience in the western transmission area of Mexico. In: 37th Annual Western Protective Relay Conference, pp. 1–12 (2010)Google Scholar
  7. 7.
    Altuve, H.J.; Schweitzer, E.O.: Modern Solution for Protection, Control, and Monitoring of Electric Power Systems. Schweitzer Engineering Laboratories, Inc Pullman, Washington (2010)Google Scholar
  8. 8.
    Xia, Y.Q.; Li, K.K.; David, A.K.: Adaptive relay setting for stand-alone digital distance protection. IEEE Trans. Power Deliv. 9(1), 480–491 (1994)CrossRefGoogle Scholar
  9. 9.
    Wheeler, S.A.: Influence of mutual coupling between parallel circuits on the setting of distance protection. Proc. Inst. Electr. Eng. 117(2), 439–445 (1970)CrossRefGoogle Scholar
  10. 10.
    Mir, M.: Adaptive vs. conventional reach setting of digital distance relays. Electr. Power Syst. Res. 43, 105–111 (1997)CrossRefGoogle Scholar
  11. 11.
    Hu, Y.; Novosel, D.; Saha, M.M.; Leitloff, V.: An adaptive scheme for parallel-line distance protection. IEEE Trans. Power Deliv. 17(1), 105–110 (2002)CrossRefGoogle Scholar
  12. 12.
    Upendar, J.; Gupta, C.P.; Singh, G.K.: Comprehensive adaptive distance relaying scheme for parallel transmission lines. IEEE Trans. Power Deliv. 26(2), 1039–1052 (2011)CrossRefGoogle Scholar
  13. 13.
    Biswal, M.: Adaptive distance relay algorithm for double circuit line with series compensation. Measurement 53, 206–214 (2014)CrossRefGoogle Scholar
  14. 14.
    Makwana, V.H.; Bhalja, B.: New adaptive digital distance relaying scheme for double infeed parallel transmission line during inter-circuit faults. IET Gener. Transm. Distrib. 5(6), 667–673 (2011)CrossRefGoogle Scholar
  15. 15.
    Biswal, M.; Pati, B.B.; Pradhan, A.K.: Adaptive distance relay setting for series compensated line. Int. J. Electr. Power Energy Syst. 52, 198–206 (2013)CrossRefGoogle Scholar
  16. 16.
    Bachmatiuk, A.; Izykowski, J.: Distance protection performance under inter-circuit faults on double-circuit transmission line. Przeglad Elektrotechniczny 89, 7–11 (2013)Google Scholar
  17. 17.
    Pradhan, A.K.; Joos, G.: Adaptive distance relay setting for lines connecting wind farms. IEEE Trans. Energy Convers. 22(1), 206–213 (2007)CrossRefGoogle Scholar
  18. 18.
    Tsuboi, T.; Takami, J.; Okabe, S.; Aoki, K.; Yamagata, Y.: Study on a field data of secondary arc extinction time for large-sized transmission lines. IEEE Trans. Dielectr. Electr. Insul. 20(6), 2277–2286 (2013)CrossRefGoogle Scholar
  19. 19.
    Jena, P.; Pradhan, A.K.: Directional relaying during single-pole tripping using phase change in negative-sequence current. IEEE Trans. Power Deliv. 28(3), 1548–1557 (2013)CrossRefGoogle Scholar
  20. 20.
    Kundu, P.; Pradhan, A.K.: Enhanced protection security using the system integrity protection schemes (SIPS). IEEE Trans. Power Deliv. 31(1), 228–235 (2016)CrossRefGoogle Scholar
  21. 21.
    Calero, F.; Hou, D.: Practical considerations for single-pole-trip line-protection schemes. In: IEEE Engineering Annual Conference, pp. 69–85 (2005)Google Scholar
  22. 22.
    Angell, D.; Hou, D.: Input source error concerns for protective relays. In: 33rd Annual Western Protective Relay Conference, pp. 1–8 (2006)Google Scholar
  23. 23.
    Huping, Y.; Dongwerr, W.; Yin, G.; Zhipeng, B.: Analysis on fault voltage and secondary arc current of single phase refusing-shut of the 500 kV extra high voltage transmission line. In: 2nd International Conference on Power Electronics and Intelligent Transportation System, pp. 9–12 (2009)Google Scholar
  24. 24.
    Ma, J.; Xiang, X.; Li, P.; Deng, Z.; Thorp, J.S.: Adaptive distance protection scheme with quadrilateral characteristic for extremely high-voltage/ultra-high-voltage transmission line. IET Gener. Transm. Distrib. 11(7), 1624–1633 (2017)CrossRefGoogle Scholar

Copyright information

© King Fahd University of Petroleum & Minerals 2018

Authors and Affiliations

  1. 1.Department of Electrical and Electronics EngineeringBITS-Pilani Goa CampusSancoaleIndia
  2. 2.Department of Electrical EngineeringIndian Institute of Technology RoorkeeRoorkeeIndia

Personalised recommendations