Experimental Behavior of RC Columns, Confined with Stirrup and Strips, Under Cyclic Axial Load
- 99 Downloads
- 1 Citations
Abstract
This paper presents the experimental behavior of columns confined with passive steel strips instead of standard deformed stirrups. Three types of steel strips having width with thickness ratios as 7.5, 12.4 and 18.8 were used. To compare results stirrup with 6.35 mm in diameter were also used as confining reinforcement. Cross-sectional area of each strip was kept the same and was equivalent to 6.35 mm diameter deformed bars. All the columns were tested under cyclic axial load and behavior of columns, in terms of performance of hooks and stress–strain relationship, was compared. It was found that strength of column increases as width to thickness ratio increases. However, when width to thickness ratio of strips increases from 12.4 to 18.8, the resulting increases in strength decreases. It was also found that the technique used to provide hooks to the strips needs improvement.
Keywords
Columns Confinement Strips Stirrups Stress–strain curves Axial compression HooksPreview
Unable to display preview. Download preview PDF.
References
- 1.Sheikh, S.A.; Uzumeri, S.M.: Strength and ductility of confined colums. J. Struct. Div. ASCE 106(No STS), 1079–1102 (1980)Google Scholar
- 2.King J.W.H.: The effect of lateral reinforcement in reinforced concrete columns. Struct. Eng. 24(7): 355–388 (1946)Google Scholar
- 3.Bunni, N.G.: Rectangular ties in reinforced concrete columns. In: American Concrete Institute Special Publication SP50-8, pp. 193–210 (1975)Google Scholar
- 4.Sheikh, S.A.: Effectiveness of rectangular ties as confinement steel in reinforced concrete columns. PhD Dissertation, Department of Civil Engineering, University of Toronto, pp. 256 (1978)Google Scholar
- 5.Soliman M.T.M., Yu C.W.: Flexural stress–strain relationship of concrete confined by rectangular transverse reinforcement. Mag. Concr. Res. (London) 19(61): 223–238 (1967)CrossRefGoogle Scholar
- 6.Cusson D., Paultre Last P.: High strength concrete columns confined by rectangular ties. J. Struct. Eng. 120(3): 783–804 (1994)CrossRefGoogle Scholar
- 7.Yong Y.-K., Nour M.G., Nawy E.G.: Behavior of laterally confined high strength concrete columns axial loads. J. Struct. Eng. 114(2): 332–350 (1988)CrossRefGoogle Scholar
- 8.Nemecek, J.; Padevet, P.; Patzak, B.; Bittnar, Z.: Effect of transversal reinforcement on normal and high strength concrete columns. Mater. Struct. 665–671 (2005)Google Scholar
- 9.Mander J.B., Priestly M.J.N., Park R.: Observed stress strain behavior of confined concrete. J. Struct. Eng. 114(8): 1827–1848 (1988)CrossRefGoogle Scholar
- 10.Hudson, F.M.: Reinforced concrete columns: effects of lateral tie spacing on ultimate strength. In: Paper No. 10, Symposium on Reinforced Concrete Columns, American Concrete Institute Special Publications SP, vol. 13, pp. 235–244 (1966)Google Scholar
- 11.Sargin, M.; Ghosh, S.K.; Handa, V.K.: Effect of lateral reinforcement upon the strength and deformation properties of concrete. Mag. Concr. Res. (London) 23(76) 99–110 (1971)Google Scholar
- 12.Chung, H.-S.; Yang, K.-H.; Lee, Y.-H.; Eun, H.-C.: Stress strain curves of laterally confined concrete. Eng. Struct. 24, 1153–1163 (2002)Google Scholar
- 13.Paultre P., Légeron F., Mongeau D.: Influence of concrete strength and yield strength of ties on the behavior of high-strength concrete columns. ACI Struct. J. 98(4): 490–501 (2001)Google Scholar
- 14.Richart, F.E.; Brandtzaeg, A.; Brown, R.L.: The failure of plan and spirally reinforced concrete in compression. In: Bulletio 190. University of Illinois Engineering Experimental Station, Champaign (1929)Google Scholar
- 15.Park, R.; Leslie, P.D.: Curvature ductility of circular reinforced concrete columns confined by the ACI spiral. In: 6th Australasian Conference on the Mechanics of Structures and Materials, vol. 1, pp. 342–349 (1977)Google Scholar
- 16.Ahmed S.H., Shah S.P.: Stress strain curves of concrete confined by spiral reinforcement. ACI J. 79, 484–490 (1982)Google Scholar
- 17.Martinze, S.; Nilson, A.H.; Slate, F.O.: Spirally reinforced high strength concrete columns. ACI J. 81, 431–442 (1984)Google Scholar
- 18.Rizvi S.R., Saatcioglu M.: Confinement of reinforced columns with welded wire fabric. ACI Struct. J. 86, 615–623 (1990)Google Scholar
- 19.Moghaddam, H.; Samadi, M.; Pilakoutas, K.; Mohebbi, S.: Axial compressive behavior of concrete actively confined by metal strips part A: experimental study. Mater. Struct. 43 (2010)Google Scholar
- 20.Benzaid, R.; Chikh, N.E.; Mesbah, H.: Study of the compressive behavior of short concrete columns confined by fiber reinforced composite. Arab. J. Sci. Eng. 34(1B), 15–26 (2009)Google Scholar
- 21.Chikh N., Benzaid R., Mesbah H.: An experimental investigation of circular RC columns with various slenderness confined with CFRP sheets. Arab. J. Sci. Eng. 37(2): 315–323 (2012)CrossRefGoogle Scholar
- 22.Rizwan, M.: Performance evaluation of RC structures under earthquake loading. Thesis (PhD), Civil Engineering Department, UET, Lahore (2010)Google Scholar
- 23.ACI Committee 318: Building code requirements for reinforced concrete (ACI 318-06) and commentary-ACI318RM-06. American Concrete Institute, Detroit (2006)Google Scholar
- 24.Sinha B.P., Gerstle K.H., Tulin L.G.: Stress strain relation for concrete under cyclic loading. Am. Concr. Inst. J. 61(2): 195–211 (1964)Google Scholar
- 25.Karson I.D., Jirsa J.O.: Behavior of concrete under compressive loadings. J. Struct. Eng. Div. ASCE 95(12): 2543–2563 (1969)Google Scholar
- 26.Mander, J.B.; Priestley, M.J.N.; Park, R.: Seismic design of Bridge Piers. In: Research Report No. 84.2. University of Canterbury, NewZealand (1984)Google Scholar
- 27.Sakai, J.; Kawashima, K.: An unloading and reloading stress–strain model for concrete confined by tie reinforcements. In: 12 WCEE (2000 pages), pp. 1431–1431 (1988)Google Scholar