High blood pressure (BP) or hypertension is the single most crucial adjustable risk factor for cardiovascular diseases (CVDs) and monitoring the arterial blood pressure (ABP) is an efficient way to detect and control the prevalence of the cardiovascular health of patients. Therefore, monitoring the regulation of BP during patients’ daily life plays a critical role in the ambulatory setting and the latest mobile health technology. In recent years, many studies have been conducted to explore the feasibility and performance of such techniques in the health care system. The ultimate aim of these studies is to find and develop an alternative to conventional BP monitoring by using cuff-less, easy-to-use, fast, and cost-effective devices for controlling and lowering the physical harm of CVDs to the human body. However, most of the current studies are at the prototype phase and face a range of issues and challenges to meet clinical standards. This review focuses on the description and analysis of the latest continuous and cuff-less methods along with their key challenges and barriers. Particularly, most advanced and standard technologies including pulse transit time (PTT), ultrasound, pulse arrival time (PAT), and machine learning are investigated. The accuracy, portability, and comfort of use of these technologies, and the ability to integrate to the wearable healthcare system are discussed. Finally, the future directions for further study are suggested.

Keywords

Continuous blood pressure monitoring Cuff-less Non-invasive Pulse transit time Pulse arrival time 

Notes

Compliance with ethical standards

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

References

  1. 1.
    Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL, Jones DW, Materson BJ, Oparil S, Wright JT (2003) Seventh report of the joint national committee on prevention, detection, evaluation, and treatment of high blood pressure. Hypertension 42(6):1206–1252CrossRefGoogle Scholar
  2. 2.
    Williams JS, Brown SM, Conlin PR (2009) Blood-pressure measurement. N Engl J Med 360(5):e6PubMedPubMedCentralCrossRefGoogle Scholar
  3. 3.
    Modesti PA, Agostoni P, Agyemang C, Basu S, Benetos A, Cappuccio FP, Ceriello A, Del Prato S, Kalyesubula R, O’Brien E (2014) Cardiovascular risk assessment in low-resource settings: a consensus document of the European Society of Hypertension Working Group on Hypertension and Cardiovascular Risk in Low Resource Settings. J Hypertens 32(5):951PubMedPubMedCentralCrossRefGoogle Scholar
  4. 4.
    Mensah GA, Croft JB, Giles WH (2002) The heart, kidney, and brain as target organs in hypertension. Cardiol Clin 20(2):225–247PubMedCrossRefGoogle Scholar
  5. 5.
    World Health Organization (WHO) Global Health Observatory (GHO) data https://www.who.int/mediacentre/factsheets/fs317/en/. Accessed 10 Aug 2018
  6. 6.
    Forouzanfar MH, Alexander L, Anderson HR, Bachman VF, Biryukov S, Brauer M, Burnett R, Casey D, Coates MM, Cohen A (2015) Global, regional, and national comparative risk assessment of 79 behavioural, environmental and occupational, and metabolic risks or clusters of risks in 188 countries, 1990–2013: a systematic analysis for the global burden of disease study 2013. Lancet 386(10010):2287–2323PubMedCrossRefGoogle Scholar
  7. 7.
    Chow CK, Teo KK, Rangarajan S, Islam S, Gupta R, Avezum A, Bahonar A, Chifamba J, Dagenais G, Diaz R (2013) Prevalence, awareness, treatment, and control of hypertension in rural and urban communities in high, middle, and low-income countries. JAMA 310(9):959–968PubMedCrossRefGoogle Scholar
  8. 8.
    Lim SS, Vos T, Flaxman AD, Danaei G, Shibuya K, Adair-Rohani H, AlMazroa MA, Amann M, Anderson HR, Andrews KG (2012) A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990–2010: a systematic analysis for the global burden of disease study 2010. Lancet 380(9859):2224–2260PubMedPubMedCentralCrossRefGoogle Scholar
  9. 9.
    Pickering TG, Shimbo D, Haas D (2006) Ambulatory blood-pressure monitoring. N Engl J Med 354(22):2368–2374PubMedCrossRefGoogle Scholar
  10. 10.
    Hermida RC, Smolensky MH, Ayala DE, Portaluppi F, Crespo JJ, Fabbian F, Haus E, Manfredini R, Mojon A, Moya A (2013) 2013 Ambulatory blood pressure monitoring recommendations for the diagnosis of adult hypertension, assessment of cardiovascular and other hypertension-associated risk, and attainment of therapeutic goals: joint recommendations from the International Society for Chronobiology (ISC), American Association of Medical Chronobiology and Chronotherapeutics (AAMCC), Spanish Society of Applied Chronobiology, Chronotherapy, and Vascular Risk (SECAC). Chronobiol Int 30(3):355–410PubMedCrossRefGoogle Scholar
  11. 11.
    Group SR (2015) A randomized trial of intensive versus standard blood-pressure control. N Engl J Med 2015(373):2103–2116CrossRefGoogle Scholar
  12. 12.
    Zheng Y-L, Ding X-R, Poon CCY, Lo BPL, Zhang H, Zhou X-L, Yang G-Z, Zhao N, Zhang Y-T (2014) Unobtrusive sensing and wearable devices for health informatics. IEEE Trans Biomed Eng 61(5):1538–1554PubMedCrossRefPubMedCentralGoogle Scholar
  13. 13.
    Steinhubl SR, Muse ED, Barrett PM, Topol EJ (2016) Off the cuff: rebooting blood pressure treatment. Lancet 388(10046):749PubMedCrossRefGoogle Scholar
  14. 14.
    Moran AE, Odden MC, Thanataveerat A, Tzong KY, Rasmussen PW, Guzman D, Williams L, Bibbins-Domingo K, Coxson PG, Goldman L (2015) Cost-effectiveness of hypertension therapy according to 2014 guidelines. N Engl J Med 372(5):447–455PubMedPubMedCentralCrossRefGoogle Scholar
  15. 15.
    Ghasemzadeh N, Zafari AM (2011) A brief journey into the history of the arterial pulse. Cardiol Res Pract.  https://doi.org/10.4061/2011/164832 CrossRefPubMedPubMedCentralGoogle Scholar
  16. 16.
    Fye WB (1993) Disorders of the heartbeat: a historical overview from antiquity to the mid-20th century. Am J Cardiol 72(14):1055–1070PubMedCrossRefGoogle Scholar
  17. 17.
    O’Rourke MF, O’Brien C, Edelman ER (2016) Arterial stiffening in perspective: advances in physical and physiological science over centuries. Am J Hypertens 29(7):785–791PubMedPubMedCentralCrossRefGoogle Scholar
  18. 18.
    Ward M, Langton JA (2007) Blood pressure measurement. Continuing education in anaesthesia, Crit Care Pain 7(4):122–126Google Scholar
  19. 19.
    Chung E, Chen G, Alexander B, Cannesson M (2013) Non-invasive continuous blood pressure monitoring: a review of current applications. Front Med 7(1):91–101PubMedCrossRefGoogle Scholar
  20. 20.
    Mukkamala R, Hahn J-O, Inan OT, Mestha LK, Kim C-S, Töreyin H, Kyal S (2015) Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice. IEEE Trans Biomed Eng 62(8):1879–1901PubMedPubMedCentralCrossRefGoogle Scholar
  21. 21.
    Shin JH, Lee KM, Park KS (2009) Non-constrained monitoring of systolic blood pressure on a weighing scale. Physiol Meas 30(7):679PubMedCrossRefGoogle Scholar
  22. 22.
    Wu K-f, Chan C-h, Zhang Y-t (2016) Contactless and cuffless monitoring of blood pressure on a chair using e-textile materials. 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors, pp 98–100Google Scholar
  23. 23.
    Poon CC, Wong YM, Zhang Y-t (2006) M-health: the development of cuff-less and wearable blood pressure meters for use in body sensor networks. Life Science Systems and Applications Workshop, IEEE/NLM. IEEE, pp 1–2Google Scholar
  24. 24.
    Shaltis PA, Reisner AT, Asada HH (2008) Cuffless blood pressure monitoring using hydrostatic pressure changes. IEEE Trans Biomed Eng 55(6):1775–1777PubMedCrossRefGoogle Scholar
  25. 25.
    Zhang Y-t, Poon CC, Chan C-h, Tsang MW, Wu K-f (2006) A health-shirt using e-textile materials for the continuous and cuffless monitoring of arterial blood pressure. 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors, pp 86–89Google Scholar
  26. 26.
    Poon CC, Zhang Y-T, Bao S-D (2006) A novel biometrics method to secure wireless body area sensor networks for telemedicine and m-health. IEEE Commun Mag 44(4):73–81CrossRefGoogle Scholar
  27. 27.
    Jeong IC, Finkelstein J (2016) Introducing contactless blood pressure assessment using a high speed video camera. J Med Syst 40(4):77PubMedCrossRefPubMedCentralGoogle Scholar
  28. 28.
    Ding X-R, Zhao N, Yang G-Z, Pettigrew RI, Lo B, Miao F, Li Y, Liu J, Zhang Y-T (2016) Continuous blood pressure measurement from invasive to unobtrusive: celebration of 200th birth anniversary of carl ludwig. IEEE J Biomed Health Inform 20(6):1455–1465PubMedCrossRefGoogle Scholar
  29. 29.
    ANSI A (2002) & ANSI/AAMI SP10: 2002/A1: 2003. American National Standard Manual, electronic, or automated sphygmomanometersGoogle Scholar
  30. 30.
    O’Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, Altman D, Bland M, Coats A, Atkins N (1993) The British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens 11(Suppl 2):S43–S62Google Scholar
  31. 31.
    Perloff D, Grim C, Flack J, Frohlich ED, Hill M, McDonald M, Morgenstern BZ (1993) Human blood pressure determination by sphygmomanometry. Circulation 88(5):2460–2470PubMedCrossRefGoogle Scholar
  32. 32.
    Taha Z, Shirley L, Razman MAM (2017) A review on non-invasive hypertension monitoring system by using photoplethysmography method. Mov Health Exerc 6(1):47–57Google Scholar
  33. 33.
    Peter L, Noury N, Cerny M (2014) A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? IRBM 35(5):271–282CrossRefGoogle Scholar
  34. 34.
    Alpert BS, Quinn D, Gallick D (2014) Oscillometric blood pressure: a review for clinicians. J Am Soc Hypertens 8(12):930–938PubMedCrossRefGoogle Scholar
  35. 35.
    Forouzanfar M, Ahmad S, Batkin I, Dajani HR, Groza VZ, Bolic M (2013) Coefficient-free blood pressure estimation based on pulse transit time–cuff pressure dependence. IEEE Trans Biomed Eng 60(7):1814–1824PubMedCrossRefGoogle Scholar
  36. 36.
    Zheng D, Di Marco LY, Murray A (2014) Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement. Med Biol Eng Comput 52(5):467–473PubMedPubMedCentralGoogle Scholar
  37. 37.
    Kim S-H, Lilot M, Sidhu KS, Rinehart J, Yu Z, Canales C, Cannesson M (2014) Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology 120(5):1080–1097PubMedCrossRefGoogle Scholar
  38. 38.
    Hansen S, Staber M (2006) Oscillometric blood pressure measurement used for calibration of the arterial tonometry method contributes significantly to error. Eur J Anaesthesiol 23(9):781–787PubMedCrossRefGoogle Scholar
  39. 39.
    Kontis V, Mathers CD, Rehm J, Stevens GA, Shield KD, Bonita R, Riley LM, Poznyak V, Beaglehole R, Ezzati M (2014) Contribution of six risk factors to achieving the 25 × 25 non-communicable disease mortality reduction target: a modelling study. Lancet 384(9941):427–437PubMedCrossRefGoogle Scholar
  40. 40.
    McGhee BH, Bridges EJ (2002) Monitoring arterial blood pressure: what you may not know. Crit Care Nurse 22:60–79PubMedGoogle Scholar
  41. 41.
    Brzezinski M, Luisetti T, London MJ (2009) Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Int Anesth Res Soc 109(6):1763–1781Google Scholar
  42. 42.
    Li-wei HL, Saeed M, Talmor D, Mark R, Malhotra A (2013) Methods of blood pressure measurement in the ICU. Crit Care Med 41(1):34CrossRefGoogle Scholar
  43. 43.
    Hennig A, Patzak A (2013) Continuous blood pressure measurement using pulse transit time. Somnologie-Schlafforschung und Schlafmedizin 17(2):104–110CrossRefGoogle Scholar
  44. 44.
    Ding X, Dai W, Luo N, Liu J, Zhao N, Zhang Y (2015) A flexible tonoarteriography-based body sensor network for cuffless measurement of arterial blood pressure. IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN), pp 1–4Google Scholar
  45. 45.
    Ding X-R, Zhang Y-T, Liu J, Dai W-X, Tsang HK (2016) Continuous cuffless blood pressure estimation using pulse transit time and photoplethysmogram intensity ratio. IEEE Trans Biomed Eng 63(5):964–972PubMedCrossRefGoogle Scholar
  46. 46.
    Ding X-R, Zhang Y-T (2015) Photoplethysmogram intensity ratio: A potential indicator for improving the accuracy of PTT-based cuffless blood pressure estimation. 2015 IEEE 37th Annual International Conference of the Engineering in Medicine and Biology Society (EMBC), pp 398–401Google Scholar
  47. 47.
    Ding X-R, Zhang Y-T, Tsang HK (2016) A new modeling methodology for continuous cuffless blood pressure measurement. 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI). IEEE, pp 264–267Google Scholar
  48. 48.
    Lin W-H, Wang H, Samuel OW, Li G (2017) Using a new PPG indicator to increase the accuracy of PTT-based continuous cuffless blood pressure estimation. 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp 738–741Google Scholar
  49. 49.
    Liu J, Zhang Y-T, Ding X-R, Dai W-X, Zhao N (2016) A preliminary study on multi-wavelength PPG based pulse transit time detection for cuffless blood pressure measurement. IEEE 38th Annual International Conference of the Engineering in Medicine and Biology Society (EMBC), pp 615–618Google Scholar
  50. 50.
    Liu J, Li Y, Ding X-R, Dai W-X, Zhang Y-T (2015) Effects of cuff inflation and deflation on pulse transit time measured from ECG and multi-wavelength PPG. IEEE 37th Annual International Conference of the Engineering in Medicine and Biology Society (EMBC), pp 5973–5976Google Scholar
  51. 51.
    Jeong IC, Finkelstein J (2016) Introducing contactless blood pressure assessment using a high speed video camera. J Med Syst 40(4):1–10CrossRefGoogle Scholar
  52. 52.
    Sun Y, Thakor N (2016) Photoplethysmography revisited: from contact to noncontact, from point to imaging. IEEE Trans Biomed Eng 63(3):463–477PubMedCrossRefGoogle Scholar
  53. 53.
    Ghosh S, Banerjee A, Ray N, Wood PW, Boulanger P, Padwal R (2016) Continuous blood pressure prediction from pulse transit time using ECG and PPG signals. IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT), pp 188–191Google Scholar
  54. 54.
    Visvanathan A, Sinha A, Pal A (2013) Estimation of blood pressure levels from reflective photoplethysmograph using smart phones. IEEE 13th International Conference on Bioinformatics and Bioengineering (BIBE), pp 1–5Google Scholar
  55. 55.
    Atef M, Xiyan L, Wang G, Lian Y (2016) PTT based continuous time non-invasive blood pressure system. IEEE 59th International Midwest Symposium on Circuits and Systems (MWSCAS), pp 1–4Google Scholar
  56. 56.
    Junior AD, Murali S, Rincon F, Atienza D (2016) Methods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors. Microprocess Microsyst 46:84–95CrossRefGoogle Scholar
  57. 57.
    Dai W-X, Zhang Y-T, Liu J, Ding X-R, Zhao N (2016) Dual-modality arterial pulse monitoring system for continuous blood pressure measurement. IEEE 38th Annual International Conference of the Engineering in Medicine and Biology Society (EMBC), pp 5773–5776Google Scholar
  58. 58.
    Yang C, Tavassolian N (2017) Pulse transit time measurement using seismocardiogram, photoplethysmogram, and acoustic recordings: evaluation and comparison. IEEE J Biomed Health Inform 22(3):733–740PubMedCrossRefPubMedCentralGoogle Scholar
  59. 59.
    Van Velzen MH, Loeve AJ, Niehof SP, Mik EG (2017) Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves. Med Biol Eng Comput 55(11):1989–2000PubMedPubMedCentralCrossRefGoogle Scholar
  60. 60.
    Ibrahim B, Nathan V, Jafari R (2017) Exploration and validation of alternate sensing methods for wearable continuous pulse transit time measurement using optical and bioimpedance modalities. In: 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp 2051–2055Google Scholar
  61. 61.
    Carek AM, Conant J, Joshi A, Kang H, Inan OT (2017) SeismoWatch: wearable cuffless blood pressure monitoring using pulse transit time. Proc ACM Interact Mob Wearable Ubiquitous Technol 1(3):40PubMedPubMedCentralCrossRefGoogle Scholar
  62. 62.
    Chen Y, Cheng S, Wang T, Ma T (2017) Novel blood pressure estimation method using single photoplethysmography feature. 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp 1712–1715Google Scholar
  63. 63.
    Buxi D, Redouté J-M, Yuce MR (2017) Blood pressure estimation using pulse transit time from bioimpedance and continuous wave radar. IEEE Trans Biomed Eng 64(4):917–927PubMedCrossRefGoogle Scholar
  64. 64.
    Sola J, Proença M, Ferrario D, Porchet J-A, Falhi A, Grossenbacher O, Allemann Y, Rimoldi SF, Sartori C (2013) Noninvasive and nonocclusive blood pressure estimation via a chest sensor. IEEE Trans Biomed Eng 60(12):3505–3513PubMedCrossRefGoogle Scholar
  65. 65.
    Prabhu V, Kuppusamy P, Karthikeyan A, Sucharitha M (2018) A novel approach for non-invasive measurement of mean arterial pressure using pulse transit time. Multimed Tools Appl.  https://doi.org/10.1007/s11042-018-6971-8 CrossRefGoogle Scholar
  66. 66.
    Meinders JM, Hoeks AP (2004) Simultaneous assessment of diameter and pressure waveforms in the carotid artery. Ultrasound Med Biol 30(2):147–154PubMedCrossRefGoogle Scholar
  67. 67.
    Weber S, Scharfschwerdt P, Schauer T, Seel T, Kertzscher U, Affeld K (2013) Continuous wrist blood pressure measurement with ultrasound. Biomed Eng.  https://doi.org/10.1515/bmt-2013-4124 CrossRefGoogle Scholar
  68. 68.
    Seo J, Pietrangelo SJ, Lee H-S, Sodini CG (2015) Noninvasive arterial blood pressure waveform monitoring using two-element ultrasound system. IEEE Trans Ultrason Ferroelectr Freq Control 62(4):776–784PubMedCrossRefGoogle Scholar
  69. 69.
    Joseph J, Nabeel P, Shah MI, Sivaprakasam M (2016) Arterial compliance probe for calibration free pulse pressure measurement. IEEE International Symposium on Medical Measurements and Applications (MeMeA), pp 1–6Google Scholar
  70. 70.
    Zakrzewski AM, Anthony BW (2017) Arterial blood pressure estimation using ultrasound: clinical results on healthy volunteers and a medicated hypertensive volunteer. 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp 2154–2157Google Scholar
  71. 71.
    Ding X-R, Zhang Y-T, Tsang HK (2016) A New Modeling Methodology for Continuous Cuffless Blood Pressure Measurement. IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI), pp 264–267Google Scholar
  72. 72.
    Escobar B, Torres R (2014) Feasibility of non-invasive blood pressure estimation based on pulse arrival time: a MIMIC Database Study. Computing in Cardiology Conference (CinC), pp 1113–1116Google Scholar
  73. 73.
    Tang Z, Tamura T, Sekine M, Huang A, Chen W, Yoshida M, Sakatani K, Kobayashi H, Kanaya S (2016) A chair-based unobtrusive cuffless blood pressure monitoring system based on pulse arrival time. IEEE J Biomed Health Informat 21(5):1194–1205CrossRefGoogle Scholar
  74. 74.
    Zhang Q, Chen X, Fang Z, Xue Y, Zhan Q, Yang T, Xia S (2017) Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter. J Micromech Microeng 27(2):024002CrossRefGoogle Scholar
  75. 75.
    Zheng Y, Poon CC, Yan BP, Lau JY (2016) Pulse arrival time based cuff-less and 24-H wearable blood pressure monitoring and its diagnostic value in hypertension. J Med Syst 40(9):195PubMedCrossRefGoogle Scholar
  76. 76.
    Rajala S, Ahmaniemi T, Lindholm H, Taipalus T (2017) Pulse arrival time (PAT) measurement based on arm ECG and finger PPG signals-comparison of PPG feature detection methods for PAT calculation. 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp 250–253Google Scholar
  77. 77.
    Wu TH, Pang GK-H, Kwong EW-Y (2014) Predicting systolic blood pressure using machine learning. 7th International Conference on Information and Automation for Sustainability (ICIAfS), pp 1–6Google Scholar
  78. 78.
    Yoshioka M, Bounyong S (2017) Regression-forests-based estimation of blood pressure using the pulse transit time obtained by facial photoplethysmogram. 2017 International Joint Conference on Neural Networks (IJCNN), pp 3248–3253Google Scholar
  79. 79.
    He R, Huang Z-P, Ji L-Y, Wu J-K, Li H, Zhang Z-Q (2016) Beat-to-beat ambulatory blood pressure estimation based on random forest. IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN), pp 194–198Google Scholar
  80. 80.
    Zhang Y, Feng Z (2017) A SVM method for continuous blood pressure estimation from a PPG signal. Proceedings of the 9th International Conference on Machine Learning and Computing. ACM, pp 128–132Google Scholar
  81. 81.
    Xing X, Sun M (2016) Optical blood pressure estimation with photoplethysmography and FFT-based neural networks. Biomed Opt Express 7(8):3007–3020PubMedPubMedCentralCrossRefGoogle Scholar
  82. 82.
    Xu Z, Liu J, Chen X, Wang Y, Zhao Z (2017) Continuous blood pressure estimation based on multiple parameters from eletrocardiogram and photoplethysmogram by back-propagation neural network. Comput Ind 89:50–59CrossRefGoogle Scholar
  83. 83.
    Miao F, Fu N, Zhang Y-T, Ding X-R, Hong X, He Q, Li Y (2017) A novel continuous blood pressure estimation approach based on data mining techniques. IEEE J Biomed Health Informat 21(6):1730–1740CrossRefGoogle Scholar
  84. 84.
    Atomi K, Kawanaka H, Bhuiyan MS, Oguri K (2017) Cuffless blood pressure estimation based on data-oriented continuous health monitoring System. Comput Math Methods Med.  https://doi.org/10.1155/2017/1803485 CrossRefPubMedPubMedCentralGoogle Scholar
  85. 85.
    Xu J, Jiang J, Zhou H, Yan Z (2017) A novel blood pressure estimation method combing pulse wave transit time model and neural network model. 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp 2130–2133Google Scholar
  86. 86.
    Campo D, Khettab H, Yu R, Genain N, Edouard P, Buard N, Boutouyrie P (2017) Measurement of aortic pulse wave velocity with a connected bathroom scale. Am J Hypertens 30(9):876–883PubMedPubMedCentralCrossRefGoogle Scholar
  87. 87.
    Hsieh Y-Y, Wu C-D, Lu S-S, Tsao Y (2016) A linear regression model with dynamic pulse transit time features for noninvasive blood pressure prediction. IEEE of Biomedical Circuits and Systems Conference (BioCAS), pp 604–607Google Scholar
  88. 88.
    Rodrigues JC, Amadu AM, Ghosh Dastidar A, McIntyre B, Szantho GV, Lyen S, Godsave C, Ratcliffe LE, Burchell AE, Hart EC (2016) ECG strain pattern in hypertension is associated with myocardial cellular expansion and diffuse interstitial fibrosis: a multi-parametric cardiac magnetic resonance study. Eur Heart J 18(4):441–450Google Scholar
  89. 89.
    Saeki M, Sato N, Kawasaki M, Tanaka R, Nagaya M, Watanabe T, Ono K, Noda T, Zile MR, Minatoguchi S (2015) Left ventricular layer function in hypertension assessed by myocardial strain rate using novel one-beat real-time three-dimensional speckle tracking echocardiography with high volume rates. Hypertens Res 38(8):551PubMedCrossRefGoogle Scholar
  90. 90.
    Madani A, Arnaout R, Mofrad M, Arnaout R (2018) Fast and accurate view classification of echocardiograms using deep learning. npj Dig Med 1 (1):6CrossRefGoogle Scholar
  91. 91.
    van Everdingen WM, Maass AH, Vernooy K, Meine M, Allaart CP, De Lange FJ, Teske AJ, Geelhoed B, Rienstra M, Van Gelder IC (2017) Comparison of strain parameters in dyssynchronous heart failure between speckle tracking echocardiography vendor systems. Cardiovasc Ultrasound 15(1):25PubMedPubMedCentralCrossRefGoogle Scholar
  92. 92.
    Lee S, Chang J-H (2017) Oscillometric blood pressure estimation based on deep learning. IEEE Trans Industr Inf 13(2):461–472CrossRefGoogle Scholar
  93. 93.
    Lee S, Chang J-H (2017) Deep learning ensemble with asymptotic techniques for oscillometric blood pressure estimation. Comput Methods Programs Biomed 151:1–13PubMedCrossRefGoogle Scholar
  94. 94.
    Peng Su, Xiao-Rong Ding, Yuan-Ting Zhang, Jing Liu, Fen Miao, Zhao N (2018) Long-term blood pressure prediction with deep recurrent neural networks. 2018 IEEE Conference on Biomedical and Health Informatics (BHI)Google Scholar
  95. 95.
    Zhao Q, Hu X, Lin J, Deng X, Li H (2019) A novel short-term blood pressure prediction model based on LSTM. AIP Conference Proceedings. vol 1. AIP Publishing, p 020003Google Scholar
  96. 96.
    Association IS (2014) IEEE standard for wearable cuffless blood pressure measuring devices. IEEE Std 1708–2014Google Scholar
  97. 97.
    O'Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, Imai Y, Wang J, Mengden T, Shennan A (2010) European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit 15(1):23–38PubMedCrossRefPubMedCentralGoogle Scholar
  98. 98.
    Tsinalis O, Matthews PM, Guo Y, Zafeiriou S (2016) Automatic sleep stage scoring with single-channel EEG using convolutional neural networks. Cornell University, IthacaGoogle Scholar

Copyright information

© Australasian College of Physical Scientists and Engineers in Medicine 2019

Authors and Affiliations

  • Solmaz Rastegar
    • 1
    Email author
  • Hamid GholamHosseini
    • 1
  • Andrew Lowe
    • 1
  1. 1.School of Engineering, Computer, and Mathematical SciencesAuckland University of TechnologyAucklandNew Zealand

Personalised recommendations