Abstract

New advancements in the management of type I diabetic patients (T1DM) call for a new generation of monitoring systems based upon an array of metabolic biosensors including sensors for insulin detection. Blood insulin values are always less than 270 pM; therefore, specifically designed insulin sensors have to provide a limit of detection in the range of few pico-molar units. At present, electrochemical sensors are one of the best options to provide low-cost technologies for diabetes mellitus monitoring and treatment. Moreover, modern nanotechnology permits to improve further their performances by providing new materials, structured at the nanoscale (i.e., carbon nanotubes), which alter the original sensor properties when used for both in vivo and in vitro biosensing applications. A recent article in literature has proposed a solution based on electrochemical sensors that promise performances in line with above-mentioned insulin detection requirements. However, data presented in this paper show that such a promise is still overestimated, and an electrochemical sensor capable of insulin detection within the physiological range is still beyond the present state of the art even when adopting nanostructured working electrodes.

Keywords

Insulin detection Multiwalled carbon nanotubes Silicon nanoparticles Screen-printed electrodes Amperometric biosensors 

Notes

Acknowledgments

This study was conducted within the frame of the i-IronIC Project, which aimed at developing novel and highly reliable wearable biosensors for the monitoring of different human metabolic conditions. The i-IronIC project was financed by a grant by the Swiss Nano-Tera.ch initiative and evaluated by the Swiss National Science Foundation.

References

  1. 1.
    Seshasai, S. R., Kaptoge, S., Thompson, A., Di Angelantonio, E., Gao, P., Sarwar, N., et al. (2011). Diabetes mellitus, fasting glucose, and risk of cause-specific death. The New England Journal of Medicine, 364, 829–41.CrossRefGoogle Scholar
  2. 2.
    Campbell, I. W., Duncan, C., Patton, N. W., Broadhead, T., Tucker, G. T., Woods, H. F. (1987). The effect of metformin on glycaemic control, intermediary metabolism and blood pressure in non-insulin-dependent diabetes mellitus. Diabetic Medicine, 4, 337–341.CrossRefGoogle Scholar
  3. 3.
    Valgimigli, F., Lucarelli, F., Scuffi, C., Morandi, S., Sposato, I. (2010). Evaluating the clinical accuracy of GlucoMen® day: a novel microdialysis-based continuous glucose monitor. Journal of Diabetes Science and Technology, 4, 1182–1192.Google Scholar
  4. 4.
    Guiseppi-Elie, A., Lei, C., Baughman, R. H. (2002). Direct electron transfer of glucose oxidase on carbon nanotubes. Nanotechnology, 13, 559–564.CrossRefGoogle Scholar
  5. 5.
    Shumyantseva, V. V., Carrara, S., Bavastrello, V., Jason Riley, D., Bulko, T. V., Skryabin, K. G., et al. (2005). Direct electron transfer between cytochrome P450scc and gold nanoparticles on screen-printed rhodium–graphite electrodes. Biosensors and Bioelectronics, 21, 217–222.CrossRefGoogle Scholar
  6. 6.
    Erokhin, V., Carrara, S., Amenitch, H., Bernstorff, S., Nicolini, C. (1998). Semiconductor nanoparticles for quantum devices. Nanotechnology, 9, 158.CrossRefGoogle Scholar
  7. 7.
    Svancara, I., Prior, C., Hocevar, S. B., Wangc, J. (2010). A decade with bismuth-based electrodes in electroanalysis. Electroanalysis, 22, 1405–1420.CrossRefGoogle Scholar
  8. 8.
    Winzella, M. S., Wulffb, E. M., Olsenb, G. S., Sauerbergb, P., Gotfredsenb, C. F., Ahréna, B. (2010). Improved insulin sensitivity and islet function after PPARδ activation in diabetic db/db mice. European Journal of Pharmacology, 626, 297–305.CrossRefGoogle Scholar
  9. 9.
    Salimi, A., Mohamadi, L., Hallaj, R., Soltanian, S. (2009). Electrooxidation of insulin at silicon carbide nanoparticles modified glassy carbon electrode. Electrochemistry Communications, 11, 1116–1119.CrossRefGoogle Scholar
  10. 10.
    Boero, C., Carrara, S., De Micheli, G. (2009). Sensitivity enhancement by carbon nanotubes: applications to stem cell cultures monitoring. Proceedings of IEEE PRIME Conference, pp. 72–75.Google Scholar
  11. 11.
    Baj-Rossi, C., De Micheli, G., Carrara, S. (2012). Electrochemical detection of anti-breast-cancer agents in human serum by cytochrome P450-coated carbon nanotubes. Sensors, 12, 6520–6537.CrossRefGoogle Scholar
  12. 12.
    Carrara, S., Cavallini, A., Erokhin, V., De Micheli, G. (2011). Multi-panel drugs detection in human serum for personalized therapy. Biosensors and Bioelectronics, 26, 3914–3919.CrossRefGoogle Scholar
  13. 13.
    Carrara, S. (2012). Bio/CMOS interfaces and co-design (pp. 208–209). New York: Springer.Google Scholar

Copyright information

© Springer Science+Business Media New York 2013

Authors and Affiliations

  • Fabrizio Mastrantonio
    • 1
  • Francesco Valgimigli
    • 1
  • Lucia Grassi
    • 2
  • Paolo Cappa
    • 2
  • Giovanni De Micheli
    • 3
  • Sandro Carrara
    • 3
  1. 1.A.Menarini DiagnosticsFlorenceItaly
  2. 2.Department of Mechanical and Aerospace Engineering, Faculty of Civil and Industrial EngineeringSapienza University of RomeRomeItaly
  3. 3.Laboratory of Integrated SystemsEPFL—École Polytechnique Fédérale de LausanneLausanneSwitzerland

Personalised recommendations