Abstract

To compare the radiation dose delivered by Positron Emission Tomography (PET) due to Gallium-68 (68Ga) and Fluorine-18(18F) performed for patients with prostate cancer. The greatest importance is to understand how the extremely strong sources in use can be managed effectively and doses to persons and unwanted doses to patients can be minimized. Thus, Radiation safety measurements are necessary to achieve the lowest exposure with reasonable cost and effort. We prospectively analyzed studies from 70 patients who underwent PET-CT using 68Ga or 18F for diagnosis of prostate cancer between January 2017 and December 2017 at the American University of Beirut Medical Center. The dose rates were measured during the uptake period at patient body surface (abdomen) and at 1 m distance; these two points were measured after one hour of radionuclide uptake with background of 0.018 μSv. Then, the equivalent dose is calculated. Patients were selected consecutively until 70 cases were selected for each type of radionuclide. Data on 140 patients are presented. The maximum dose given to 68Ga PSMA (prostate-specific membrane antigen) patients was 5.80 mCi while doses to 18F-Choline patients reached 8.87 mCi. Cronbach’s Alpha values for the correlation between the masses and the dose rates was 0.530.Thus there is a small positive relationship between the body masses and the dose rates. This relationship is not statistically significant. Furthermore, the equivalent dose for both radionuclides was constant whatever the mass of the patient is. There is no effect of the body mass with respect to the dose rate, and equivalent dose due to both radionuclides 68Ga and 18F, which coincides with the principles of radiation protection. This leads to the suggestion that PET/CT equivalent doses with 68Ga-labelled PSMA ligand or 18F-Choline are similar and safe in the diagnosis of prostate cancer. However, 68Ga PSMA coincides more with radiation protection principles since the maximum equivalent dose due to 68Ga after 1 h at 1 m was 17.71 μSv while the maximum equivalent dose due to 18F after 1 h at 1 m was 39.51 μSv.

Keywords

Prostate cancer PET/CT Positron emission tomography PSMA Choline Dose rate Absorbed dose Effective dose 

Abbreviations

PET

Positron Emission Tomography

CT

Computed Tomography

PC

Prostate Cancer

PSMA

Prostate-Specific Membrane Antigen

Inj

Injection

Notes

Authors contributions

Zeinab Khansa: contributed data collection and manuscript preparation.

Mohamad B. Haidar: contributed to data collection, study design and manuscript editing.

Nemer Neaimeh: contributed to data collection.

Mahmoud Korek: contributed to study design.

All authors read and approved the final manuscript.

Compliance with ethical standards

Consent for publication

Not applicable.

Availability of data and materials

All relevant data and materials are available upon request.

Conflict of interest

None to declare.

References

  1. 1.
    International Commission on Radiological Protection. Radiological protection in medicine. ICRP Publication 105. Ann ICRP. 2007;37:1–63.Google Scholar
  2. 2.
    Menzel F et al. Using of BEPU methodology in a final safety analysis report. 2015.Google Scholar
  3. 3.
    ICRP. What is radiation dose? http://www.icrp.org/icrpaedia/dose.asp
  4. 4.
    Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D. Global cancer statistics. CA: CA Cancer J Clin. 2011;61:69–90.Google Scholar
  5. 5.
    Shamseddine A, Saleh A, Charafeddine M, Seoud M, Mukherji D, Temraz S, et al. Cancer trends in Lebanon: a review of incidence rates for the period of 2003–2008 and projections until 2018. Popul Health Metr. 2014;12:4.CrossRefGoogle Scholar
  6. 6.
    Grant FD et al. Skeletal PET with^ 1^ 8F-Fluoride: applying new technology to an old tracer. J Nuclear Med. 2008: 68.Google Scholar
  7. 7.
    Pagani M, Stone-Elander S, Larsson SA. Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications. Eur J Nucl Med. 1997:1301–27.Google Scholar
  8. 8.
    Production challenges of Gallium-68 labeled radiopharmaceuticals. https://www.comecer.com/nl/gallium-68-radiopharmaceuticals-production-challenges/.
  9. 9.
    Dwivedi DK et al. Radiation exposure to nuclear medicine personnel handling positron emitters from Ge-68/Ga-68 generator. Indian J Nucl Med: IJNM: Off J Soc Nucl Med, India. 2011: 86.Google Scholar
  10. 10.
    International Commission on Radiological Protection. Committee IV on Protection Against Electromagnetic Radiation Above 3 MeV and Electrons, Neutrons, and Protons. Radiation protection; recommendations of the International Commission on Radiological Protection: Report of Committee IV (1953–1959) on Protection against Electromagnetic Radiation above 3 MeV and Electrons, Neutrons and Protons. Adopted 1962, with revisions adopted in 1963. Vol. 4. Published for the International Commission on Radiological Protection [by] MacMillan, 1964.Google Scholar
  11. 11.
    Kendall GM, Smith TJ. Doses to organs and tissues from radon and its decay products. J Radiol Prot. 2002:389.Google Scholar
  12. 12.
    Valentin J. Basic anatomical and physiological data for use in radiological protection: reference values: ICRP publication 89.Ann ICRP. 2002: 1–277.Google Scholar
  13. 13.
    Martin CJ. Effective dose: how should it be applied to medical exposures?. The British J Radiol. 2007: 639–647.Google Scholar
  14. 14.
    Salame-Alfie A. Assessing dose of the representative person for the purpose of radiation protection of the public and the optimization of radiological protection: broadening the process. Health Phys. 2008: 373–374.Google Scholar
  15. 15.
    Ferrari A, Pelliccioni M, Pillon M. Fluence to effective dose and effective dose equivalent conversion coefficients for photons from 50 keV to 10 GeV. Radiat Prot Dosim. 1996: 245–251.Google Scholar
  16. 16.
    Pant GS, Senthamizhchelvan S. Radiation exposure to staff in a PET/CT facility. Indian J Nucl Med. 2006: 100–3.Google Scholar
  17. 17.
    Demir M et al. Radiation protection for accompanying person and radiation workers in PET/CT. Radiation Protect Dosimet. 2010: 528–532.Google Scholar
  18. 18.
    Benatar NA, Cronin BF, O'doherty M. Radiation doses received by staff and carers/escorts following contact with IsF-FDG PET patients. 1999: 462.Google Scholar

Copyright information

© IUPESM and Springer-Verlag GmbH Germany, part of Springer Nature 2019

Authors and Affiliations

  • Zeinab Khansa
    • 1
  • Mohamad B. Haidar
    • 2
    Email author
  • Nemer Neaimeh
    • 2
  • Mahmoud Korek
    • 1
  1. 1.Department of PhysicsBeirut Arab UniversityBeirutLebanon
  2. 2.Department of Diagnostic RadiologyAmerican University of Beirut Medical CenterBeirutLebanon

Personalised recommendations