Input signal effects on the locomotion of a robotic colonoscope activated by a flexible shaft

  • Seonggun Joe
  • Dongkyu Lee
  • Jong-Oh Park
  • Sukho Park
  • Byungkyu Kim
Short Communication
  • 49 Downloads

Abstract

Most robotic colonoscopes do not allow sufficient space for high capacity motors since their power sources are equipped in their bodies. Therefore, a robotic colonoscope activated by an external motor through a flexible shaft has been presented. Unfortunately, robot rotations resulting from excessive input torque are observed under some input voltage signals. These rotations occur when the load torque on the flexible shaft exceeds a critical torque value, which is the maximum torque satisfying the rigid body condition. The excessive-torque effect must be eliminated since each rotation causes a velocity reduction as well as twisting of the colon. Therefore, to suppress the rotation by reducing the load torque, the input and load torques are investigated in connection to the input signal. Conclusively, the maximum load torque of the triangular function is the smallest among the input signals and does not exceed the critical torque, which causes the rotation of the robot body. To verify the usefulness of the theoretical and experimental load torque results, in-vitro tests are performed in an acrylic pipe and excised colon for all input functions. As expected with the load torque results according to the input signal, the robot with the triangular function achieves the best performance regardless of experimental environment.

Keywords

Robotic colonoscope Flexible shaft DC motor control Robot rotation In-vitro test 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Dario, P. and Mosse, C., “Review of Locomotion Techniques for Robotic Colonoscopy,” Proc. of IEEE International Conference on Robotics and Automation, pp. 1086–1091, 2003.Google Scholar
  2. 2.
    Wang, K. D. and Yan, G. Z., “An Earthworm-Like Microrobot for Colonoscopy,” Biomedical Instrumentation & Technology, Vol. 40, No. 6, pp. 471–478, 2006.CrossRefGoogle Scholar
  3. 3.
    Kim, B., Lim, H. Y., Park, J. H., and Park, J.-O., “Inchworm-Like Colonoscopic Robot with Hollow Body and Steering Device,” JSME International Journal Series C Mechanical Systems, Machine Elements and Manufacturing, Vol. 49, No. 1, pp. 205–212, 2006.CrossRefGoogle Scholar
  4. 4.
    Hu, H., Wang, P., Zhao, B., Li, M., and Sun, L., “Design of a Novel Snake-Like Robotic Colonoscope,” Proc. of IEEE International Conference on Robotics and Biomimetics (ROBIO), pp. 1957–1961, 2009.Google Scholar
  5. 5.
    Utsugi, M., “Tubular Medical Instrument Having a Flexible Sheath Driven by a Plurality of Cuffs,” US Patent, 4148307A, 1979.Google Scholar
  6. 6.
    Treat, M. R. and Trimmer, W. S., “Self-Propelled Endoscope using Pressure Driven Linear Actuators,” US Patent, 5595565A, 1997.Google Scholar
  7. 7.
    Park, H.-J., Leem, S.-H., and Kim, B.-K., “Inchworm-Like Robotic Colonoscope Usinglegs for Clamping,” Transactions of the Korean Society of Mechanical Engineers A, Vol. 34, No. 6, pp. 789–795, 2010.CrossRefGoogle Scholar
  8. 8.
    Yang, S., Park, K., Kim, J., Kim, T. S., Cho, I.-J., and Yoon, E.-S., “Autonomous Locomotion of Capsule Endoscope in Gastrointestinal Tract,” Proc. of 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 6659–6663, 2011.CrossRefGoogle Scholar
  9. 9.
    Park, K., Yang, S., Kim, J., Kim, T. S., and Yoon, E.-S., “Improvement of Locomotive Performance of Capsular Microrobot Moving in GI Tract using Position based Feedback Control,” Proc. of 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 6076–6079, 2009.CrossRefGoogle Scholar
  10. 10.
    Collins, E. R. and Huang, Y., “A Programmable Dynamometer for testing Rotating Machinery using a Three-Phase Induction Machine,” IEEE Transactions on Energy Conversion, Vol. 9, No. 3, pp. 521–527, 1994.CrossRefGoogle Scholar
  11. 11.
    Newton, R. W., Betz, R. E., and Penfold, H. B., “Emulating Dynamic Load Characteristics using a Dynamic Dynamometer,” Proc. of International Conference on Power Electronics and Drive Systems, pp. 465–470, 1995.Google Scholar

Copyright information

© Korean Society for Precision Engineering and Springer-Verlag Berlin Heidelberg 2017

Authors and Affiliations

  • Seonggun Joe
    • 1
  • Dongkyu Lee
    • 1
  • Jong-Oh Park
    • 2
  • Sukho Park
    • 2
  • Byungkyu Kim
    • 1
  1. 1.School of Aerospace and Mechanical EngineeringKorea Aerospace UniversityGyeonggi-doSouth Korea
  2. 2.School of Mechanical EngineeringChonnam National UniversityGwangjuSouth Korea

Personalised recommendations