Current Cardiovascular Imaging Reports

, Volume 1, Issue 1, pp 25–29 | Cite as

Three-dimensional speckle tracking

  • Leopoldo Pérez de Isla
  • David Vivas
  • Jose Zamorano
Article

Abstract

Two-dimensional speckle tracking is a useful technology. Nevertheless, it has some limitations because the heart has three dimensions. The recent development of three-dimensional speckle tracking technology provides a new diagnostic tool. By using this new method, a more complete and probably accurate evaluation of global and segmental left ventricular function may be performed. Three-dimensional speckle tracking is a promising tool to provide new insights into left ventricular function.

Keywords

Cardiac Resynchronization Therapy Tissue Doppler Imaging Speckle Tracking Speckle Tracking Echocardiography Myocardial Strain 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References and Recommended Reading

  1. 1.
    Marwick TH: Measurement of strain and strain rate by echocardiography: ready for prime time? J Am Coll Cardiol 2006, 47:1313–1327.PubMedCrossRefGoogle Scholar
  2. 2.
    Amundsen BH, Helle-Valle T, Edvardsen T, et al.: Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging. J Am Coll Cardiol 2006, 47:789–793.PubMedCrossRefGoogle Scholar
  3. 3.
    Perk G, Tunick PA, Kronzon I: Non-Doppler two-dimensional strain imaging by echocardiography: from technical considerations to clinical applications. J Am Soc Echocardiogr 2007, 20:234–243.PubMedCrossRefGoogle Scholar
  4. 4.
    Toyoda T, Baba H, Akasaka T, et al.: Assessment of regional myocardial strain by a novel automated tracking system from digital image files. J Am Soc Echocardiogr 2004, 17:1234–1238.PubMedCrossRefGoogle Scholar
  5. 5.
    Leitman M, Lysyansky P, Sidenko S, et al.: Two dimensional strain-a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr 2004, 17:1021–1029.PubMedCrossRefGoogle Scholar
  6. 6.
    Ingul CB, Torp H, Aase SA, et al.: Automated analysis of strain rate and strain: feasibility and clinical applications. J Am Soc Echocardiogr 2005, 18:411–418.PubMedCrossRefGoogle Scholar
  7. 7.
    Notomi Y, Lysyansky P, Setser RM, et al.: Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging. J Am Coll Cardiol 2005, 45:2034–2041.PubMedCrossRefGoogle Scholar
  8. 8.
    Suffoletto MS, Dohi K, Cannesson M, et al.: Novel speckle tracking radial strain form routine black-and-white echocardiography images to quantify dyssynchrony and predict response to cardiac resynchronization therapy. Circulation 2006, 113:960–968.PubMedCrossRefGoogle Scholar

Copyright information

© Springer 2008

Authors and Affiliations

  • Leopoldo Pérez de Isla
    • 1
  • David Vivas
  • Jose Zamorano
  1. 1.Echocardiographic LaboratoryHospital Clínico San CarlosMadridSpain

Personalised recommendations