Advertisement

Indian Journal of Clinical Biochemistry

, Volume 34, Issue 1, pp 76–81 | Cite as

A Study on Free Light Chain Assay and Serum Immunofixation Electrophoresis for the Diagnosis of Monoclonal Gammopathies

  • Eldho Kuriakose
  • Sumithra Narayanan Unni CheppayilEmail author
  • Subhakumari Kuzhikandathil Narayanan
  • Anu Vasudevan
Original Research Article
  • 65 Downloads

Abstract

Demonstration of monoclonal immunoglobulin molecule in serum forms the mainstay in the diagnosis of monoclonal gammopathies. The major tests that help in this regard are serum protein electrophoresis (SPEP), serum immunofixation electrophoresis (sIFE) and serum free light chain assay (sFLC). Our objectives were to study the accuracy of sFLC and sIFE in the diagnosis of monoclonal gammopathies and also to study the role of combination of SPEP + sIFE + sFLC in the diagnosis of the same. 46 patients who attended the hemato-oncology clinic with signs and symptoms suggestive of monoclonal gammopathy were enrolled in this study. SPEP, sIFE, sFLC and pre-treatment serum beta-2 microglobulin levels were analysed among the study population. Both SPEP and sIFE were performed in the Interlab Genios fully automated machine. Serum beta-2 microglobulin and sFLC were estimated by immunoturbidimetry in Beckman Coulter AU 2700 analyzer. The accuracy of sIFE came to be 80% with respect to sFLC assay. Sensitivity, specificity, positive and negative predictive value of sIFE with respect to sFLC were 81.3, 78.6, 89.7 and 64.7% respectively. It was observed that a combination panel of SPEP + sIFE + sFLC could detect all the cases of myeloma included in this study. Further testing in large samples is required for generalising the findings of this study. The pre-treatment beta-2 microglobulin levels were significantly higher in the group which was positive for myeloma. A combination panel of SPEP + sIFE + sFLC prove to be more useful than individual tests for the detection of myeloma.

Keywords

Monoclonal immunoglobulin Serum protein electrophoresis MGUS Serum immunofixation electrophoresis Plasma cell dyscrasias 

Notes

Compliance with Ethical Standards

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical Approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed Consent

Informed consent was obtained from all individual participants included in the study.

References

  1. 1.
    Kyle RA. The monoclonal gammopathies. Clin Chem. 1994;40(11):2154–61.PubMedGoogle Scholar
  2. 2.
    International Myeloma Working Group. Criteria for the classification of monoclonal gammopathies, multiple myeloma and related disorders: a report of the International Myeloma Working Group. Br J Haematol. 2003;121(5):749–57.CrossRefGoogle Scholar
  3. 3.
    Bradwell AR, Carr-Smith HD, Mead GP, Tang LX, Showell PJ, Dravson MT, et al. Highly sensitive, automated immunoassay for immunoglobulin free light chains in serum and urine. Clin Chem. 2001;47(4):673–80.PubMedGoogle Scholar
  4. 4.
    Sun T, Lien YY, Degnan T. Study of gammopathies with immunofixation electrophoresis. Am J Clin Pathol. 1979;72:5–11.CrossRefGoogle Scholar
  5. 5.
    Bradwell AR. Immunoglobulin free light chains and their analysis. In: Bradwell AR, editor. Serum free light chain analysis. The Binding Site: Birmingham; 2006. p. 49.Google Scholar
  6. 6.
    Piehler AP, Gulbrandsen N, Kierulf P, Urdal P. Quantitation of serum free light chains in combination with protein electrophoresis and clinical information for diagnosing multiple myeloma in a general hospital population. Clin Chem. 2008;54:1823–30.CrossRefGoogle Scholar
  7. 7.
    Katzmann JA, Clark RJ, Abraham RS, Bryant S, Lymp JF, Bradwell AR, et al. Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains. Clin Chem. 2002;48:1437–44.PubMedGoogle Scholar
  8. 8.
    MacNamara EM, Whicher JT. Electrophoresis and densitometry of serum and urine in the investigation and significance of monoclonal immunoglobulins. Electrophoresis. 1990;11:376–81.CrossRefGoogle Scholar
  9. 9.
    Cawley LP, Minard BJ, Tourtellotte WW, Ma BI, Chelle C. Immunofixation electrophoretic techniques applied to identification of proteins in serum and cerebrospinal fluid. Clin Chem. 1976;22:1262–8.PubMedGoogle Scholar
  10. 10.
    Bradwell AR, Carr-Smith HD, Mead GP, Drayson MT. Serum free light chain immunoassays and their clinical application. Clin Appl Immunol Rev. 2002;3:17–33.CrossRefGoogle Scholar
  11. 11.
    Hortin GL. Aminoacids, peptides and proteins. In: Burtis CA, Ashwood ER, Burns DE, editors. Tietz textbook of clinical chemistry and molecular diagnostics. 5th ed. Amsterdam: Elsevier; 2012. p. 538.Google Scholar
  12. 12.
    Attaelmannan M, Levinson SS. Understanding and Identifying monoclonal gammopathies. Clin Chem. 2000;46(8B):1230–8.PubMedGoogle Scholar
  13. 13.
    Molle P. Current trends in the diagnosis, therapy and monitoring of the monoclonal gammopathies. Clin Biochem Rev. 2009;30:93–103.Google Scholar
  14. 14.
    Wood PB, McElroy YG, Stone MJ. Comparison of serum immunofixation electrophoresis and free light chain assays in the detection of monoclonal gammopathies. Clin Lymphoma Myeloma Leuk. 2010;10(4):278–80.CrossRefGoogle Scholar
  15. 15.
    Katzmann JA, Abraham RS, Dispenzieri A, Lust JA, Kyle RA. Diagnostic performance of quantitative kappa and lambda free light chain assays in clinical practice. Clin Chem. 2005;51:878–81.CrossRefGoogle Scholar
  16. 16.
    Hill PG, Forsyth JM, Rai B, Mayne S. Serum free light chains: an alternative to the urine Bence Jones proteins screening test for monoclonal gammoapthies. Clin Chem. 2006;52(9):1743–8.CrossRefGoogle Scholar
  17. 17.
    Holding S, Spradbery D, Hoole R, Wilmot R, Shields ML, Levoquer AM, et al. Use of serum free light chain analysis and urine protein electrophoresis for detection of monoclonal gammopathies. Clin Chem Lab Med. 2011;49(1):83–8.CrossRefGoogle Scholar
  18. 18.
    Robson EJD, Taylor J, Beardsmore C, Basu S, Mead G, Lovatt T. Utility of serum free light chain analysis when screening for lymphoproliferative disorders: the experience at a District General Hospital in the United Kingdom. Lab Med. 2009;40(6):325–9.CrossRefGoogle Scholar
  19. 19.
    Bataille R, Boccadoro M, Klein B, Durie B, Pileri A. C-reactive protein and beta-2 microglobulin produce a sample and powerful myeloma staging system. Blood. 1992;80:733–7.PubMedGoogle Scholar
  20. 20.
    Bataille R, Durie BGM, Grenier J, Sany J. Prognostic factors and staging in multiple myeloma: a reappraisal. J Clin Oncol. 1986;4:80–7.CrossRefGoogle Scholar
  21. 21.
    Brenning G, Simonsson B, Kallander C, Ahre A. Pre-treatment serum beta-2 microglobulin in multiple myeloma. Br J Haematol. 1986;62:85–93.CrossRefGoogle Scholar
  22. 22.
    Alexanian R, Barlogie B, Fritsche H. Beta-2 microglobulin in multiple myeloma. Am J Hematol. 1985;20(4):345–51.CrossRefGoogle Scholar
  23. 23.
    Norfolk D, Child JA, Cooper EH, Kerruish S, Ward AM. Serum beta-2 microglobulin in myelomatosis: potential value in stratification and monitoring. Br J Cancer. 1979;39:510–5.CrossRefGoogle Scholar

Copyright information

© Association of Clinical Biochemists of India 2017

Authors and Affiliations

  • Eldho Kuriakose
    • 1
  • Sumithra Narayanan Unni Cheppayil
    • 1
    Email author
  • Subhakumari Kuzhikandathil Narayanan
    • 1
  • Anu Vasudevan
    • 2
  1. 1.Department of Biochemistry, Amrita Institute of Medical Sciences and Research Centre (AIMS)Amrita Viswa Vidyapeetham UniversityKochiIndia
  2. 2.Department of Biostatistics, Amrita Institute of Medical Sciences and Research Centre (AIMS)Amrita Viswa Vidyapeetham UniversityKochiIndia

Personalised recommendations