Abstract

This research presents a holistic approach to the protection of historical building group adjacent to metro line construction, in which health investigation, protection criterion determining, numerical simulation analyses, corresponding protection measures and field monitoring analyses are incorporated as main procedures. A case relating to the conservation of a seven-storey brick-wood pagoda, Longhua Pagoda, adjacent to the construction of Shanghai Metro Lines 11 and 12 in China, is presented. A reasonable protection criterion is determined rationally by means of numerical simulation based on the health investigation results combined with related standards, which can help to achieve a fine balance between system safety and cost constraints in protection measures determining. A full numerical model is developed to analyze the effect of dewatering, excavation, tunneling, and shield departure/reception, and corresponding measures are adopted to ensure the safety of the pagoda. Especially a brand new method, steel jacket method, is introduced in detail, which has a good performance on decreasing the amount of dewatering and maintaining a stable working face. Results demonstrate the application potential of the proposed approach, as well as its feasibility. The proposed approach can be used in the industry by practitioners to provide positive guidelines on the conservation of historical building group against metro line constructions. The reliable and detailed data in this case can also provide verification for subsequent research.

Key words

protection of historical building excavation tunneling steel jacket method 

CLC number

TU 473 

Document code

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    KUTUT V, ZAVADSKAS E K, LAZAUSKAS M. Assessment of priority alternatives for preservation of historic buildings using model based on ARAS and AHP methods [J]. Archives of Civil and Mechanical Engineering, 2014, 14(2): 287–294.CrossRefGoogle Scholar
  2. [2]
    MOROPOULOU A, LABROPOULOS K C, DELEGOU E T, et al. Non-destructive techniques as a tool for the protection of built cultural heritage [J]. Construction and Building Materials, 2013, 48: 1222–1239.CrossRefGoogle Scholar
  3. [3]
    CORINALDESI V. Environmentally-friendly bedding mortars for repair of historical buildings [J]. Construction and Building Materials, 2012, 35: 778–784.CrossRefGoogle Scholar
  4. [4]
    HO D C W, CHAU KW, CHEUNG A K C, et al. A survey of the health and safety conditions of apartment buildings in Hong Kong [J]. Building and Environment, 2008, 43(5): 764–775.CrossRefGoogle Scholar
  5. [5]
    HOPFE C J, AUGENBROE G L M, HENSEN J L M. Multi-criteria decision making under uncertainty in building performance assessment [J]. Building and Environment, 2013, 69: 81–90.CrossRefGoogle Scholar
  6. [6]
    ZHANG L M, WU X G, SKIBNIEWSKI M J, et al. Conservation of historical buildings in tunneling environments: Case study of Wuhan metro construction in China [J]. Construction and Building Materials, 2015, 82: 310–322.CrossRefGoogle Scholar
  7. [7]
    BOSCARDIN M D, CORDING E J. Building response to excavation-induced settlement [J]. Journal of Geotechnical Engineering, 1989, 115(1): 1–21.CrossRefGoogle Scholar
  8. [8]
    OU C Y, TENG F C, WANG IW. Analysis and design of partial ground improvement in deep excavations [J]. Computers and Geotechnics, 2008, 35(4): 576–584.CrossRefGoogle Scholar
  9. [9]
    YOO C, LEE D. Deep excavation-induced ground surface movement characteristics: A numerical investigation [J]. Computers and Geotechnics, 2008, 35(2): 231–252.CrossRefGoogle Scholar
  10. [10]
    BURLAND J B, WROTH C P. Settlement of buildings and associated damage [J]. Brick Construction, 1975, 5: 611–654.Google Scholar
  11. [11]
    SKEMPTON A W, MACDONALD D H. The allowable settlements of buildings [J]. Proceedings of the Institution of Civil Engineers, 1956, 5(6): 727–768.CrossRefGoogle Scholar
  12. [12]
    The Ministry of Construction of the People’s Republic of China. Standard for appraiser of reliability of civil buildings: GB 50292–1999 [S]. Beijing: The Ministry of Construction of the People’s Republic of China, 1999 (in Chinese).Google Scholar
  13. [13]
    The Construction Committee in Beijing, China. Standard for structure safety appraiser of buildings: DB11/T637-2009 [S]. Beijing: The Construction Committee in Beijing, China, 2009 (in Chinese).Google Scholar
  14. [14]
    MENG Z B, CHANG Y Z, SONG L, et al. The effects of micro-vibration excited by traffic vehicles on Xi’an Bell Tower [C]//International Conference on Transportation Engineering. [s.l.]: ASCE, 2009: 37–42.Google Scholar
  15. [15]
    JIANG Y C, WANG J, FANG Y, et al. Analysis of impact of shield tunnel construction on Xi’an Bell Tower in Loess Strata [C]//International Conference on Pipelines and Trenchless Technology. [s.l.]: ASCE, 2010: 65–73.Google Scholar
  16. [16]
    WU C J, ZHANG Z X, DINGW Q, et al. Influences of construction of side-crossing shield tunnel on adjacent ancient architectures and reinforcement effect of protection measures [J]. Chinese Journal of Geotechnical Engineering, 2012, 34(1): 18–32 (in Chinese).Google Scholar
  17. [17]
    The Ministry of Industry and Information Technology of the People’s Republic of China. The method of evaluating the fired common brick strength grading by rebound hammer: JC/T796-2013 [S]. Beijing: The Ministry of Industry and Information Technology of the People’s Republic of China, 2013 (in Chinese).Google Scholar
  18. [18]
    The Ministry of Construction of the People’s Republic of China. Code for design of masonry structures: GB50003-2011 [S]. Beijing: The Ministry of Construction of the People’s Republic of China, 2012 (in Chinese).Google Scholar
  19. [19]
    The Ministry of Construction of the People’s Republic of China. Technical code for monitoring of building foundation pit engineering: GB50497-2009 [S]. Beijing: The Ministry of Construction of the People’s Republic of China, 2009 (in Chinese).Google Scholar
  20. [20]
    XU Z H, WANG W D, WANG J H. Monitoring and analysis of the deep foundation pit of Shanghai bank building in soft soil ground in Shanghai [J]. Chinese Journal of Rock Mechanics and Engineering, 2004, 23(sup 1): 4639–4644 (in Chinese).Google Scholar
  21. [21]
    ZHANG J F, CHEN J J, WANG J H, et al. Prediction of tunnel displacement induced by adjacent excavation in soft soil [J]. Tunnelling and Underground Space Technology, 2013, 36: 24–33.CrossRefGoogle Scholar
  22. [22]
    WANGW, DOU J Z, CHEN J J, et al. Numerical analysis of the soil compaction degree under multi-location tamping [J]. Journal of Shanghai Jiao Tong University (Science), 2017, 22(4): 417–433.CrossRefGoogle Scholar
  23. [23]
    CHEN J J, ZHANG L Y, ZHANG J F, et al. Field tests, modification, and application of deep soil mixing method in soft clay [J]. Journal of Geotechnical and Geoenvironmental Engineering, 2012, 139(1): 24–34.CrossRefGoogle Scholar

Copyright information

© Shanghai Jiaotong University and Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  • Fan Fan (范凡)
    • 1
  • Jinjian Chen (陈锦剑)
    • 1
  • Jianhua Wang (王建华)
    • 1
  1. 1.Department of Civil EngineeringShanghai Jiao Tong UniversityShanghaiChina

Personalised recommendations