Exergy analysis is used as a tool to evaluate exergy losses in the steam-water jet injector so as to improve its overall performance. What this article addresses here is mainly about a parametric study on the injector under various operating conditions, such as different inlet water temperature, inlet steam pressure, pressure ratio, entrainment ratio and flowrate ratio. In addition, the irreversible losses in the component parts of the two-stage injector were analyzed in detail. The results show that the operating parameters have great effects on exergy efficiency of the injector. The average exergy efficiency of the two-stage injector is 21% more than that of the single-stage one. Moreover, calculations based on experimental data indicate that the highest exergy losses due to irreversibility occur in the first-stage mixing chamber. In light of this comparison, the exergy losses occurring in the system are proportional to the exergy efficiency obtained by applying the system.
Key words
Exergy Steam-water Jet Injector Two-stage Efficiency Entrainment RatioPreview
Unable to display preview. Download preview PDF.
References
- 1.H. El-Dessouky, H. Ettouney, I. Alatiqi and G. Al-Nuwaibit, Chem. Eng. Process., 41, 551 (2002).CrossRefGoogle Scholar
- 2.O. S. Kim, Y. Lee and D. H. Lee, Korean J. Chem. Eng., 26, 288 (2009).CrossRefGoogle Scholar
- 3.Nabil Beithou and Hikmet S. Aybar, Int. J. Multiphase Flow, 26, 1609 (2000).CrossRefGoogle Scholar
- 4.S. Balamurugan, Mayank D. Lad, Vilas G. Gaikar and Ashwin W. Patwardhan, Chem. Eng. J., 131, 83 (2007).CrossRefGoogle Scholar
- 5.M. I. Kim, O. S. Kim, D. H. Lee and S. D. Kim, Chem. Eng. Sci., 62, 7133 (2007).CrossRefGoogle Scholar
- 6.Mortaza Yari, Int. J. Therm. Sci., 48, 1997 (2009).CrossRefGoogle Scholar
- 7.Giuseppe Grazzini and Andrea Rocchetti, Int. J. Refrigeration, 25, 621 (2002).CrossRefGoogle Scholar
- 8.Marian Trela, Roman Kwidzinski, Dariusz Butrymowicz and Jaroslaw Karwacki, Appl. Therm. Eng., 30, 340 (2010).CrossRefGoogle Scholar
- 9.Yiping Dai, Jiangfeng Wang and Lin Gao, Appl. Therm. Eng., 29, 1983 (2009).CrossRefGoogle Scholar
- 10.A. Bejan, G. Tsatsaronis and M. Moran, Thermal Design and Optimization, Inc., New York, NY (1996).Google Scholar
- 11.Junjie Yan, Daotong Chong and Xinzhuang Wu, Appl. Therm. Eng., 30, 623 (2010).CrossRefGoogle Scholar