Skip to main content
Log in

De-airing an open stent graft to potentially reduce spinal cord injury

  • How to Do It
  • Published:
General Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

We have occasionally observed a bubble leaving the suture line of an open stent graft; hence, we hypothesized that de-airing an open stent graft could potentially reduce spinal cord injury. Postoperative computed tomography often showed residual air in thoracic aortic aneurysms, confirmed by the presence of a certain amount of air in an open stent graft in a dry lab. We filled CO2 in the sterilized package of an open stent graft and subsequently filled it with saline, which absorbed the CO2 and entered into the gap of the graft. The clinical benefit of de-airing an open stent graft to reduce the incidence of spinal cord injury needs to be evaluated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Uchida N. Open stent grafting for complex diseases of the thoracic GTCS aorta: clinical utility. Gen Thorac Cardiovasc Surg. 2013;61(3):118–26.

    Article  PubMed  Google Scholar 

  2. Ma WG, Zheng J, Sun LZ, Elefteriades JA. Open stented grafts for frozen elephant trunk technique: Technical aspect and current outcomes. Aorta(Stanford). 2015;3(4):122–36.

    Google Scholar 

  3. Zipfel B, Buz S, Redlin M, Hullmeine D, Hammerschmidt R, Hetzer R. Spinal cord ischemia after thoracic stent-grafting: causes apart from intercostal artery coverage. Ann Thorac Surg. 2013;96:31–8.

    Article  PubMed  Google Scholar 

  4. Miyairi T, Kotsuka Y, Morota T, Kubota H, Shibata K, Ikeda Y, Kitamura T, et al. Paraplegia after open surgery using endovascular stent graft for aortic arch repair. J Thorac Cardiovasc Surg. 2001;122:1240–3.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

We would like to thank Editage (http://www.editage.jp) for English language editing. We would like to thank Mr. Kumazawa Y, Mr. Kajioto R, and Mr. Yokoi N for their medical engineering support. Ethics committee approval for this technique is under investigation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Susumu Isoda.

Ethics declarations

Conflict of interest

Munetaka Masuda received research funding from Japan Lifeline Co. Ltd. Other authors do not have any conflict of interest.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (MOV 45884 KB)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Isoda, S., Izubuchi, R., Kawashima, J. et al. De-airing an open stent graft to potentially reduce spinal cord injury. Gen Thorac Cardiovasc Surg 67, 566–568 (2019). https://doi.org/10.1007/s11748-018-1044-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-018-1044-5

Keywords

Navigation