Frontiers of Materials Science in China

, Volume 3, Issue 3, pp 333–338 | Cite as

Adhesion behavior of plasma sprayed thermal barrier coatings on Al-6061 and cast iron substrates

  • N. Krishnamurthy
  • S. C. Sharma
  • M. S. Murali
  • P. G. Mukunda
Research Article

Abstract

In this work an investigation was carried out on adhesion strength and micro-hardness of plasma sprayed coatings on Al-6061 and cast iron substrate materials. For the adhesion test, ASTM C633, and for the micro hardness, ASTM E384 standards were used. From the results obtained it was found that the main failure locations were in the bond coat-substrate interface, which is considered as adhesion strength. The various parameters affecting adhesion strength are also discussed.

Keywords

adhesion strength micro-hardness plasma spraying thermal barrier coating 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    AWS. Thermal Spraying: Practice, Theory and Application. Miami, FL: American Welding Society, 1985Google Scholar
  2. 2.
    Sobolev V V, Guilemany J M, Nutting J, et al. Development of substrate-coating adhesion in thermal spraying. International Materials Reviews, 1997, 42(3): 117–136Google Scholar
  3. 3.
    Houben J M. Relationship between the adhesion of plasma sprayed coatings to the process parameters size, velocity and heat content of the spray particles. Dissertation for the Doctoral Degree. The Netherlands: Eindhoven University of Technology Eindhoven, 1988Google Scholar
  4. 4.
    Harmsworth P D, Stevens R. Microstructure of zirconia-yttria plasma-sprayed thermal barrier coatings. Journal of Materials Science, 1992, 27: 616–624CrossRefADSGoogle Scholar
  5. 5.
    Bartuli C, Bertamini L, Matera S, et al. Investigation of the formation of an amorphous film at the ZrO2-Y2O3/NiCoCrAlY interface of thermal barrier coatings produced by plasma spraying. Materials Science and Engineering: A, 1995, 199: 229–237CrossRefGoogle Scholar
  6. 6.
    Bahbou M F, Nylén P, Wigren J. Effect of grit blasting and spraying angle on the adhesion strength of a plasma-sprayed coating. Journal of Thermal Spray Technology, 2004, 13(4): 508–514CrossRefADSGoogle Scholar
  7. 7.
    Berndt C C. Cracking progresses in thermally sprayed ceramic coatings. Materials Science Forum, 1988, 34–36: 457–461Google Scholar
  8. 8.
    Era H, Otsubo F, Uchida T, et al. A modified shear test for adhesion evaluation of thermal sprayed coating. Materials Science and Engineering: A, 1998, 251(1–2): 166–172CrossRefGoogle Scholar
  9. 9.
    Zhu Y L, Ma S N, Xu B S. Finite-element evaluation and improvement of a test procedure for coating shear bond strength determination. Journal of Thermal Spray Technology, 1999, 8(2): 328–332CrossRefADSGoogle Scholar
  10. 10.
    Siegman S, Dvorak M, Grutzner H, et al. In: Lugscheider E, ed. Thermal Spray Connects: Explore its Surface Potential, Proceedings of the International Thermal Spray Conference ITSC, Basel, Switzerland, ASM International/DVS, Dusseldorf, Germany, 2005, 823Google Scholar
  11. 11.
    Hadad M, Marot G, Lesage J, et al. In: Lugscheider E, ed. Thermal Spray Connects: Explore its Surface Potential, Proceedings of the International Thermal Spray Conference ITSC, Basel, Switzerland, ASM International/DVS, Dusseldorf, Germany, 2005, 759Google Scholar
  12. 12.
    Trevisan R E, Fals H C, Lima C R C. Critical evaluation of adhesion tests in plasma sprayed metal-ceramic coatings. CIT Information Tecnologica (Chile), 2000, 11(4): 103–112Google Scholar
  13. 13.
    ASTM. Standard test method for adhesion and cohesion strength of thermal spray coating. ASTM standard C-633-01. West Conshocken, PA, USA: ASTM International, 2001Google Scholar
  14. 14.
    Janos B Z, Lugscheider E, Remer P. Effect of thermal aging on the erosion resistance of air plasma sprayed zirconia thermal barrier coatings. Surface and Coatings Technology, 1999, 113: 278–285CrossRefGoogle Scholar
  15. 15.
    Haynes J A, Ferber M K, Porter W D, et al. Mechanical properties and fracture behavior of interfacial alumina scales on plasma-sprayed thermal barrier coatings. Materials at High Temperatures, 1999, 16(2): 49–69CrossRefGoogle Scholar
  16. 16.
    Lima C R C, Guilemany J M. Adhesion improvements of thermal barrier coatings with HVOF thermally sprayed bond coats. Surface and Coatings Technology, 2007, 201(8): 4694–4701CrossRefGoogle Scholar
  17. 17.
    Limarga A M, Widjaja S, Yip T H. Mechanical properties and oxidation resistance of plasma-sprayed multilayered Al2O3/ZrO2 thermal barrier coatings. Surface and Coatings Technology, 2005, 197: 93–102CrossRefGoogle Scholar
  18. 18.
    ASTM. Standard test method for micro indentation hardness of materials. ASTM E384. West Conshocken, PA, USA: ASTM International, 2005Google Scholar

Copyright information

© Higher Education Press and Springer-Verlag GmbH 2009

Authors and Affiliations

  • N. Krishnamurthy
    • 1
  • S. C. Sharma
    • 2
  • M. S. Murali
    • 2
  • P. G. Mukunda
    • 1
  1. 1.Mechanical Engineering DepartmentNitte Meenakshi Institute of TechnologyBangaloreIndia
  2. 2.Mechanical Engineering DepartmentRV College of EngineeringBangaloreIndia

Personalised recommendations