High School Gymnasium Roof Truss Support Collapse
Case History---Peer-Reviewed
First Online:
Received:
Revised:
- 194 Downloads
- 3 Citations
Abstract
Roof truss supports from a high school gymnasium were evaluated after the roof collapsed under a heavy load of snow. The roof collapsed when the truss supports buckled. Three significant structural deficiencies were identified during the evaluation: (1) Truss supports were not gusseted, allowing for side-to-side movement. (2) Yield strength of the support was 9% below the minimum specified yield strength specified for the base material, ASTM A36. (3) Full penetration was not achieved on the butt weld between the truss and support.
Keywords
Bending Compression Distortion Ductile fracture Failure analysis Fusion welded joints Mechanical behaviorCopyright information