Advertisement

Treatment of Nonunion of Scaphoid Waist with Ni-Ti Shape-Memory Alloy Connector and Iliac Bone Graft

  • Lie-Hu Cao
  • Shuo-Gui XuEmail author
  • Ya-Le Wu
  • Chun-Cai Zhang
Article

Abstract

After fracture, the unique anatomy and blood supply of the scaphoid itself predisposes to nonunion. Scaphoid nonunion presents a formidable challenge to surgeons because of the difficulties for fixation, and the high failure rate after treatment. The Ni-Ti shape-memory alloy can provide compressive stress at the nonunion site, which is the key point for bone healing. Hence, we designed a shape-memory bone connector named arched shape-memory connector (ASC). We conducted a retrospective study looking at the union rate and complications and correlating the outcome of treatment with this device. The study reviewed a cohort of six consecutive patients presenting with scaphoid waist nonunion, who were treated with ASC and iliac cancellous bone grafting at our center from August 2002 to December 2007. The patients with nonunion achieved a 100% union rate. All the patients who achieved union had good pain relief and improved function. Our study demonstrates that scaphoid waist nonunions can be successfully treated by ASC and iliac bone grafting.

Keywords

arched shape-memory connector Ni-Ti alloy nonunion scaphoid shape memory 

Notes

Acknowledgments

This research is supported by the Nano Project of Science and Technology Commission of Shanghai Municipality (No. 1052nm03100) and the National Natural Science Foundation of China (No. 30872640/C160705)

References

  1. 1.
    L.M. Hove, Epidemiology of Scaphoid Fractures in Bergen, Norway, Scand. J. Plast. Reconstr. Surg. Hand Surg., 1999, 33(4), p 423–426CrossRefGoogle Scholar
  2. 2.
    S.P. Seinmann and J.E. Adams, Scaphoid Fracture and Nonunion: Diagnosis and Treatment, J. Orthop. Sci., 2006, 11(4), p 424–431CrossRefGoogle Scholar
  3. 3.
    G.R. Mack, M.J. Bosse, R.H. Gelberman et al., The Natural History of Scaphoid Nonunion, J. Bone Joint Surg. (Am.), 1984, 66A, p 504–509Google Scholar
  4. 4.
    L.K. Ruby, J. Stinson, and M.R. Belsky, The Natural History of Scaphoid Nonunion: A Review of Fifty-Five Cases, J. Bone Joint Surg. (Am.), 1985, 67(3), p 428–432Google Scholar
  5. 5.
    R.C. Burgess, The Effects of a Simulated Scaphoid Malunion on Wrist Motion, J. Hand Surg. (Am.), 1987, 12(6), p 774–776Google Scholar
  6. 6.
    C.C. Zhang, S.G. Xu, and J.C. Su, An Arched Shape-Memory Connector, The State Patent Office of the People’s Republic of China (Patent No. ZL 01344222.8), 5/8/2002Google Scholar
  7. 7.
    W.P. Cooney, R. Bussey, J.H. Dobyns et al., Difficult Wrist Fractures. Perilunate Fracture-Dislocations of the Wrist, Clin. Orthop. Relat. Res., 1987, 214, p 136–147Google Scholar
  8. 8.
    A. Panchal, E.N. Kubiak, M. Keshner et al., Comparison of Fixation Methods for Scaphoid Nonunions: A Biomechanical Model, Bull. NYU Hosp. Jt. Dis., 2007, 65(4), p 271–275Google Scholar
  9. 9.
    A.C. Rettig, E.J. Weidenbener, and R. Gloyeske, Alternative Management of Midthird Scaphoid Fractures in the Athlete, Am. J. Sport Med., 1994, 22(5), p 711–714CrossRefGoogle Scholar
  10. 10.
    J.A. Shaw, A Biomechanical Comparison of Scaphoid Screws, J. Hand Surg., 1987, 12A, p 347–353Google Scholar
  11. 11.
    M. Barrabés, A. Michiardi, C. Aparicio et al., Oxidized Nickel-Titanium Foams for Bone Reconstructions: Chemical and Mechanical Characterization, J. Mater. Sci. Mater. Med., 2007, 18(11), p 2123–2129CrossRefGoogle Scholar
  12. 12.
    D.S. Levi, N. Kusnezov, and G.P. Carman, Smart Materials Applications for Pediatric Cardiovascular Devices, Pediatr. Res., 2008, 63(5), p 552–558CrossRefGoogle Scholar

Copyright information

© ASM International 2011

Authors and Affiliations

  • Lie-Hu Cao
    • 1
  • Shuo-Gui Xu
    • 1
    Email author
  • Ya-Le Wu
    • 1
  • Chun-Cai Zhang
    • 1
  1. 1.Department of OrthopaedicsChanghai Hospital, Second Military Medical UniversityShanghaiChina

Personalised recommendations