Previous work has shown that hybrid semiconductor detector arrays similar to those used in infrared focal-plane arrays are very attractive for use in nuclear medicine and other gamma-ray imaging applications. In this paper, we describe the development of a 64 × 64 readout multiplexer specifically for use in gamma-ray imaging; we also describe the construction of 64 × 64 CdZnTe hybrid detector arrays using the new readout. The readout and detector array are both about one inch square (2.5 cm × 2.5 cm) and have 380 µm pixel pitch. Some initial assembly problems have been resolved by stabilizing the hybrids with epoxy. Preliminary testing results are presented that verify that the 64 × 64 CdZnTe arrays perform as excellent imaging spectrometers.
Key words
CdTe CdZnTe gamma-ray imaging hybrid gamma-ray detectors nuclear medicine readout multiplexer semiconductor detector arraysPreview
Unable to display preview. Download preview PDF.
References
- 1.B.E. Patt, A. DelDuca, R. Dolin and C. Ortale, IEEE Trans. Nucl. Sci., NS-33 (1), 523 (1986).Google Scholar
- 2.K. Zanio, Revue de Physique Appliqueé 12, 343 (1977).Google Scholar
- 3.H.B. Barber, H.H. Barrett, E.L. Dereniak, N.E. Hartsough, D.L. Perry, P.C.T. Roberts, M.M. Rogulski, J.M. Woolfenden and E.T. Young, Phys. Medica 9, 135 (1993).Google Scholar
- 4.J.F. Butler, S.J. Friesenhahn, C. Lingren, B. Apotovsky, R. Simchon, F.P. Doty, W.L. Ashburn and W. Dillon, Conf. Record of the 1993 IEEE Nucl. Sci. Symp. and Med. Imag. Conf., ed. L.A. Klaisner, (Piscataway, NJ: IEEE, 1994), p. 1, 565.Google Scholar
- 5.E. Raiskin and J. Butler, IEEE Trans. Nucl. Sci., NS-35 (1), 82 (1988).Google Scholar
- 6.C.J. Johnson, et al., Proc. 1992 Materials Research Society Symp., eds. R.B. James, T.E. Schlesinger, P. Siffert and L. Franks, 302, (Pittsburgh, PA: Mater. Res. Soc, 1993), p. 463.Google Scholar
- 7.F.P. Doty, H.B. Barber, F.L. Augustine, J.F. Butler, B.A. Apotovsky, E.T. Young and W. Hamilton, Nucl. Inst. and Meth. A 353, 361 (1994).CrossRefGoogle Scholar
- 8.H.B. Barber, J. Electron. Mater. 25 (8), 1232 (1996).CrossRefGoogle Scholar
- 9.V.R. McCready, R.P. Parker, E.M. Gunnersen, R. Ellis, E. Moss, W.G. Gore and J. Bell, Brit. J. Radiol. 44, 58 (1971).CrossRefGoogle Scholar
- 10.CM. Stahle, A. Parsons, L.M. Bartlett, P. Kurczynski, J.F. Krizmanic, L.M. Barbier, S.D. Barthelmy, F. Birsa, N. Gehrels, J. Odom, D. Palmer, C. Sappington, P. Shu, B.J. Teegarden and J. Tueller, Proc. Society of Photo-Optical and Instrumentation Engineers 2859, 74 (1994).Google Scholar
- 11.J.R. Macri, D.V. Boykin, L. Larson, M. Mayer, M.L. McConnell, J.M. Ryan, M.L. Cherry, T.G. Guzik, B.A. Apotovsky, J.F. Butler, F.P. Doty and C.L. Lingren, Proc. Society of PhotoOptical and Instrumentation Engineers, 2859, 29 (1996).Google Scholar
- 12.J.L. Matteson, W. Coburn, F. Duttweiler, T.M. Gasaway, W.A. Heindl, P.C. Leblanc, D. MacDonald, M.R. Pelling, L.E. Peterson, R.E. Rothschild, R.T. Skelton, P.L. Hink and C. Crabtree, Proc. Society of Photo-Optical and Instrumentation Engineers, 2859, 58 (1996).Google Scholar
- 13.H.B. Barber, H.H. Barrett, E.L. Dereniak, N.E. Hartsough, D.L. Perry, P.C.T. Roberts, M.M. Rogulski, J.M. Woolfenden and E.T. Young, IEEE Trans. Nucl. Sci. 40 (4), 1140 (1993).CrossRefGoogle Scholar
- 14.H.B. Barber, D.G. Marks, B.A. Apotovsky, F.L. Augustine, H.H. Barrett, J.F. Butler, E.L. Dereniak, F.P. Doty, J.D. Eskin, W.J. Hamilton, K.J. Matherson, J.E. Venzon, J.M. Woolfenden and E.T. Young, Nucl. Inst. and Meth. A380,262 (1996).Google Scholar
- 15.S. Gaalema, IEEE Trans. Nucl. Sci. NS-32 (1), 417 (1985).CrossRefGoogle Scholar
- 16.H.B. Barber, F.L. Augustine, H.H. Barrett, E.L. Dereniak, J.D. Eskin, D.G. Marks, K.J. Matherson, J.E. Venzon, J.M. Woolfenden and E.T. Young, Conf. Record of the 1995 IEEE Nucl. Sci. Symp. and Med. Imag. Conf., ed. P.A. Moonier, (Piscataway, NJ: IEEE, 1996), p. 1, 113.Google Scholar
- 17.H.B. Barber, B.A Apotovsky, F.L. Augustine, H.H. Barrett, E.L. Dereniak , F.P. Doty, J.D. Eskin, W.J.Hamilton, D.G. Marks, K.J. Matherson, J.E. Venzon, J.M. Woolfenden and E.T. Young, Nuclear Inst. and Meth. A389 (1997).Google Scholar
- 18.D.G. Marks, H.B. Barber, H.H. Barrett, E.L. Dereniak, J.D. Eskin, K.J. Matherson, J.M. Woolfenden, E.T. Young, F.L. Augustine, W.J. Hamilton, J.E. Venzon, B.A. Apotovsky and F.P. Doty, IEEE Trans. Nucl. Sci. 43 (3), 1253 (1996).CrossRefGoogle Scholar
- 19.H.H. Barrett, J.D. Eskin and H.B. Barber, Phys. Rev. Lett., 75, 156 (1995).CrossRefGoogle Scholar
- 20.J.D. Eskin, H.H. Barrett, H.B. Barber and J.M. Woolfenden, Conf. Record 1995 IEEE Nucl. Sci. Symp. and Med. Imag. Conf., ed. P.A. Moonier, (Piscataway, NJ: IEEE, 1996), p. 1, 544.Google Scholar
- 21.P.N. Luke, Appl. Phys. Lett. 65, 2884 (1994).CrossRefGoogle Scholar
- 22.J.M.Ryan, J.R. Macri, M.L. McConnell, B.K. Dann, M.L. Cherry, T.G. Guzik, F.P. Doty, B.A. Apotovsky and J.F.Butler, Proc. Society of Photo-Optical and Instrumentation Engineers, 1995, p. 2518, 292.Google Scholar
- 23.F.L. Augustine, Nucl. Inst. and Meth. A 353, 201 (1994).CrossRefGoogle Scholar
- 24.S. Kavadias, K. Misiakos and D. Loukas, IEEE Trans. Nucl. Sei. 41 (2), 397 (1994).CrossRefGoogle Scholar