Summary

This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws. A retrospective study of 7 cases (from July 2016 to December 2016), in which the guiding template printed by the threedimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis, was performed. Totally, 4 males and 3 females were included in template group, aged from 38 to 65 years old (mean 50.86±8.90). Of them, 5 had sacral fractures (3 with Denis type I and 2 with type II) and 2 the separation of sacroiliac joint. Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out. A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively. The time of each screw insertion, volume of intra-operative blood loss, and the exposure to X ray were analyzed and the Matta’s radiological criteria were used to evaluate the reduction quality. The Majeed score was used to evaluate postoperative living quality. The visual analogue scale (VAS) was applied at different time points to judge pain relief of coccydynia. All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months, mean (16.57±2.44) months. Totally 9 sacroiliac screws for the S1 and S2 vertebra were inserted in the 7 patients. The time length for each screw insertion ranged from 450 to 870 s, mean (690.56±135.68) s, and the number of times of exposure to X ray were 4 to 8, mean (5.78±1.20). The intra-operative blood loss ranged from 45 to 120 mL, mean (75±23.32) mL. According to Matta’s radiology criteria, the fracture and dislocation reduction were excellent in 6 cases and good in 1. The pre-operative VAS score ranged from 5.2 to 8.1, mean (7.13±1.00). The average one-week/six-month post-operative VAS was (5.33±0.78) and (1.33±0.66), respectively (P<0.05 when compared with pre-operative VAS). The 12-month postoperative Majeed score ranged from 86 to 92, mean (90.29±2.21). The three-dimensional printed guiding template for sacroiliac screw insertion, which could significantly shorten the operation time, provide a satisfied outcome of the stabilization of the pelvic ring, and protect doctors and patients from X-ray exposure, might be a practical and valuable new clinical technique.

Key words

sacroiliac screws three-dimensional printing technique posterior pelvic ring injury guiding template 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res, 1989,242:83–97Google Scholar
  2. 2.
    Shuler TE, Boone DC, Gruen GS, et al. Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions. J Trauma, 1995,38(3):453–458CrossRefGoogle Scholar
  3. 3.
    van den Bosch EW, van Zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma, 2002,53(1):44–48CrossRefGoogle Scholar
  4. 4.
    Routt Jr ML, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma, 1997,11(8):584–589CrossRefGoogle Scholar
  5. 5.
    Pieske C, Landersdorfer C, Trumm C, et al. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: Accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury, 2015,46(2):333–339CrossRefGoogle Scholar
  6. 6.
    Takao M, Nishii T, Sakai T, et al. Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Injury, 2014,45(6):988–994CrossRefGoogle Scholar
  7. 7.
    Behrendt D, Mutze M, Steinke H, et al. Evaluation of 2D and 3D navigation for iliosacral screw fixation. Int J Comput Assist Radiol Surg, 2012,7(2):249–255CrossRefGoogle Scholar
  8. 8.
    Heller M, Bauer HK, Goetze E, et al. Applications of patient-specific 3D printing in medicine. Int J Comput Dent, 2016,19(4):323–339Google Scholar
  9. 9.
    Lim CGT, Campbell DI, Cook N, et al. A case series of rapid prototyping and intraoperative imaging in orbital reconstruction. Craniomaxillofac Trauma Reconstr, 2015,8(2):105–110Google Scholar
  10. 10.
    Starosolski ZA, Kan JH, Rosenfeld SD, et al. Application of 3-D printing (rapid prototyping) for creating physical models of pediatric orthopedic disorders. Pediatr Radiol, 2014,44(2):216–221CrossRefGoogle Scholar
  11. 11.
    Powers MK, Lee BR, Silberstein J. Three-dimensional printing of surgical anatomy. Curr Opin Urol, 2016,26(3):283–288CrossRefGoogle Scholar
  12. 12.
    Jastifer JR, Gustafson PA. Three-Dimensional Printing and Surgical Simulation for Preoperative Planning of Deformity Correction in Foot and Ankle Surgery. J Foot Ankle Surg, 2017,56(1):191–195CrossRefGoogle Scholar
  13. 13.
    Upex P, Jouffroy P, Riouallon G. Application of 3D printing for treating fractures of both columns of the acetabulum: Benefit of pre-contouring plates on the mirrored healthy pelvis. Orthop Traumatol Surg Res, 2017,103(3):331–334CrossRefGoogle Scholar
  14. 14.
    Kim D, Lim JY, Shim KW. Sacral Reconstruction with a 3D-Printed Implant after Hemisacrectomy in a Patient with Sacral Osteosarcoma: 1-Year Follow-Up Result. Yonsei Med J, 2017,58(2):453–457CrossRefGoogle Scholar
  15. 15.
    Maini L, Sharma A, Jha S, et al. Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation? Eur J Trauma Emerg Surg, 2018,44(2):215–224.CrossRefGoogle Scholar
  16. 16.
    Guo F, Dai J, Zhang J, et al. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine. PLoS One, 2017,12(2):e0171509CrossRefGoogle Scholar
  17. 17.
    Chen XJ, Xu L, Yang Y, et al. A semi-automatic computer-aided method for surgical template design. Sci Rep, 2016,6:20280CrossRefGoogle Scholar
  18. 18.
    Philip Tack, Jan Victor, Paul Gemmel, et al. 3D-printing techniques in a medical setting: a systematic literature review. BioMed Eng Online, 2016,15(1):115CrossRefGoogle Scholar
  19. 19.
    Kim JW, Oh CW, Oh JK, et al. The incidence of and factors affecting iliosacral screw loosening in pelvic ring injury. Arch Orthop Trauma Surg, 2016,136(7):921–927CrossRefGoogle Scholar
  20. 20.
    Giráldez-Sánchez MA, Lázaro-Gonzálvez Á, Martínez-Reina J, et al. Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis. Injury, 2015,46(2):327–332Google Scholar
  21. 21.
    Radetzki F, Wohlrab D, Goehre F, et al. Anatomical conditions of the posterior pelvic ring regarding bisegmental transverse sacroiliac screw fixation: a 3D morphometric study of 125 pelvic CT datasets. Arch Orthop Trauma Surg, 2014,134(8):1115–1120CrossRefGoogle Scholar

Copyright information

© Huazhong University of Science and Technology 2018

Authors and Affiliations

  • Yi Liu
    • 1
  • Wu Zhou
    • 1
  • Tian Xia
    • 1
  • Jing Liu
    • 1
  • Bo-bin Mi
    • 1
  • Liang-cong Hu
    • 1
  • Zeng-wu Shao
    • 1
  • Guo-hui Liu
    • 1
  1. 1.Department of Orthopedics, Union Hospital, Tongji Medical CollegeHuazhong University of Science and TechnologyWuhanChina

Personalised recommendations