Abstract

This paper details the creation of experimental and computational frameworks to capture high-resolution, microscale deformation mechanisms and their relation to microstructure over large (mm-scale) fields of view. Scanning electron microscopy with custom automation and external beam control was used to capture 209 low-distortion micrographs of 360 μm × 360 μm each, that were individually correlated using digital image correlation to obtain displacement/strain fields with a spatial resolution of 0.44 μm. Displacement and strain fields, as well as secondary electron images, were subsequently stitched to create a 5.7 mm × 3.4 mm field of view containing 100 million (7678 × 13,004) data points. This approach was demonstrated on Mg WE43 under uniaxial compression, where effective strain was shown to be relatively constant with respect to distance from the grain boundary, and a noticeable increase in the effective strain was found with an increase in the basal Schmid factor. The ability to obtain high-resolution deformations over statistically relevant fields of view enables large data analytics to examine interactions between microstructure, microscale strain localizations, and macroscopic properties.

Keywords

Digital image correlation (DIC) Stitching External scan Distortion Alignment 

Notes

Acknowledgements

The authors gratefully acknowledge Mark Cornish and Darin Randall for helpful discussions and suggestions, and Remco Geurts for discussions regarding scan control and electron microscopy. This work was supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Division of Materials Sciences and Engineering under Award #DE- SC0008637 as part of the Center for PRedictive Integrated Structural Materials Science (PRISMS) at the University of Michigan. TMP, WL, JCS and ME gratefully acknowledge the support of ONR Grant N00014-16-1-2982.

References

  1. 1.
    Dingley DJ (1969) A simple straining stage for the scanning electron microscope. Micron 1:206–210Google Scholar
  2. 2.
    Roberts W, Lehtinen B, Easterling KE (1976) An in situ sem study of void development around inclusions in steel during plastic deformation. Acta Metall 24:745–758.  https://doi.org/10.1016/0001-6160(76)90109-7 CrossRefGoogle Scholar
  3. 3.
    Vehoff H, Neumann P (1979) In situ sem experiments concerning the mechanism of ductile crack growth. Acta Metall 27:915–920CrossRefGoogle Scholar
  4. 4.
    Hoskin GA, Provan JW, Gruzleski JE (1988) The in-situ fatigue testing of a cast aluminum-silicon alloy. Theor Appl Fract Mech 10:27–41CrossRefGoogle Scholar
  5. 5.
    Boehlert CJ, Cowen CJ, Tamirisakandala S et al (2006) In situ scanning electron microscopy observations of tensile deformation in a boron-modified Ti-6Al-4V alloy. Scr Mater 55:465–468.  https://doi.org/10.1016/j.scriptamat.2006.05.008 CrossRefGoogle Scholar
  6. 6.
    Boehlert CJ, Chen Z, Gutiérrez-Urrutia I et al (2012) In situ analysis of the tensile and tensile-creep deformation mechanisms in rolled AZ31. Acta Mater 60:1889–1904.  https://doi.org/10.1016/j.actamat.2011.10.025 CrossRefGoogle Scholar
  7. 7.
    Moser B, Wasmer K, Barbieri L, Michler J (2007) Strength and fracture of Si micropillars: a new scanning electron microscopy-based micro-compression test. J Mater Res 22:1004–1011.  https://doi.org/10.1557/jmr.2007.0140 CrossRefGoogle Scholar
  8. 8.
    Haque MA, Saif MTA (2002) Application of MEMS force sensors for in situ mechanical characterization of nano-scale thin films in SEM and TEM. Sensors Actuators A Phys 97–98:239–245.  https://doi.org/10.1016/S0924-4247(01)00861-5 CrossRefGoogle Scholar
  9. 9.
    Peters WH, Ranson WF (1982) Digital imaging techniques in experimental stress analysis. Opt Eng 21:427–431Google Scholar
  10. 10.
    Sutton MA, Wolters WJ, Peters WH et al (1983) Determination of displacements using an improved digital correlation method. Image Vis Comput 1:133–139.  https://doi.org/10.1016/0262-8856(83)90064-1 CrossRefGoogle Scholar
  11. 11.
    Chu TC, Ranson WF, Sutton MA (1985) Applications of digital-image-correlation techniques to experimental mechanics. Exp Mech 25:232–244.  https://doi.org/10.1007/BF02325092 CrossRefGoogle Scholar
  12. 12.
    Sutton MA, McNeill SR, Jang J, Babai M (1988) Effects of subpixel image restoration on digital correlation error estimates. Opt Eng 27:870–877.  https://doi.org/10.1117/12.7976778 CrossRefGoogle Scholar
  13. 13.
    Jin H, Lu W, Scheffel S et al (2007) Full-field characterization of mechanical behavior of polyurethane foams. Int J Solids Struct 44:6930–6944.  https://doi.org/10.1016/j.ijsolstr.2007.03.018 CrossRefzbMATHGoogle Scholar
  14. 14.
    Sutton MA, Orteu JJ, Schreier HW (2009) Image correlation for shape, motion and deformation measurements. Springer, New York.  https://doi.org/10.1007/978-0-387-78747-3 Google Scholar
  15. 15.
    Sutton MA, Li N, Joy DC et al (2007) Scanning electron microscopy for quantitative small and large deformation measurements part I: SEM imaging at magnifications from 200 to 10,000. Exp Mech 47:775–787.  https://doi.org/10.1007/s11340-007-9042-z CrossRefGoogle Scholar
  16. 16.
    Sutton MA, Li N, Garcia D et al (2007) Scanning electron microscopy for quantitative small and large deformation measurements part II: experimental validation for magnifications from 200 to 10,000. Exp Mech 47:789–804.  https://doi.org/10.1007/s11340-007-9041-0 CrossRefGoogle Scholar
  17. 17.
    Kammers AD, Daly S (2013) Self-assembled nanoparticle surface patterning for improved digital image correlation in a scanning electron microscope. Exp Mech 53:1333–1341.  https://doi.org/10.1007/s11340-013-9734-5 CrossRefGoogle Scholar
  18. 18.
    Guo SM, Sutton MA, Li N et al (2017) Measurement of local thermal deformations in heterogeneous microstructures via SEM imaging with digital image correlation. Exp Mech 57:41–56.  https://doi.org/10.1007/s11340-016-0206-6 CrossRefGoogle Scholar
  19. 19.
    Walley JL, Wheeler R, Uchic MD, Mills MJ (2012) In-situ mechanical testing for characterizing strain localization during deformation at elevated temperatures. Exp Mech 52:405–416.  https://doi.org/10.1007/s11340-011-9499-7 CrossRefGoogle Scholar
  20. 20.
    Tschopp MA, Bartha BB, Porter WJ et al (2009) Microstructure-dependent local strain behavior in polycrystals through in-situ SEM tensile experiments. Metall Mater Trans A Phys Metall Mater Sci 40:2363–2368.  https://doi.org/10.1007/s11661-009-9938-6 CrossRefGoogle Scholar
  21. 21.
    Stinville JC, Echlin MP, Texier D et al (2016) Sub-grain scale digital image correlation by electron microscopy for polycrystalline materials during elastic and plastic deformation. Exp Mech 56:197–216.  https://doi.org/10.1007/s11340-015-0083-4 CrossRefGoogle Scholar
  22. 22.
    Echlin MP, Stinville JC, Miller VM et al (2016) Incipient slip and long range plastic strain localization in microtextured Ti-6Al-4V titanium. Acta Mater 114:164–175.  https://doi.org/10.1016/j.actamat.2016.04.057 CrossRefGoogle Scholar
  23. 23.
    Scrivens WA, Luo Y, Sutton MA et al (2007) Development of patterns for digital image correlation measurements at reduced length scales. Exp Mech 47:63–77.  https://doi.org/10.1007/s11340-006-5869-y CrossRefGoogle Scholar
  24. 24.
    Gioacchino FD, da Fonseca JQ (2013) Plastic strain mapping with sub-micron resolution using digital image correlation. Exp Mech 52:743–754.  https://doi.org/10.1007/s11340-012-9685-2 CrossRefGoogle Scholar
  25. 25.
    Pan B, Yu L, Wu D (2014) High-accuracy 2D digital image correlation measurements using low-cost imaging lenses : implementation of a generalized. Meas Sci Technol 25:025001.  https://doi.org/10.1088/0957-0233/25/2/025001 CrossRefGoogle Scholar
  26. 26.
    Kammers AD, Daly S (2013) Digital image correlation under scanning electron microscopy: methodology and validation. Exp Mech 53:1743–1761.  https://doi.org/10.1007/s11340-013-9782-x CrossRefGoogle Scholar
  27. 27.
    Mello AW, Book TA, Nicolas A et al (2017) Distortion correction protocol for digital image correlation after scanning electron microscopy: emphasis on long duration and ex-situ experiments. Exp Mech 57:1395–1409.  https://doi.org/10.1007/s11340-017-0303-1 CrossRefGoogle Scholar
  28. 28.
    Maraghechi S, Hoefnagels JPM, Peerlings RHJ, Geers MGD (2018) Correction of scan line shift artifacts in scanning electron microscopy - an extended digital image correlation framework. Ultramicroscopy 187:144–163.  https://doi.org/10.1016/j.ultramic.2018.01.002 CrossRefGoogle Scholar
  29. 29.
    LePage WS, Ahadi A, Lenthe WC et al (2018) Grain size effects on NiTi shape memory alloy fatigue crack growth. J Mater Res 33:91–107.  https://doi.org/10.1557/jmr.2017.395 CrossRefGoogle Scholar
  30. 30.
    Carroll J, Abuzaid W, Lambros J, Sehitoglu H (2010) An experimental methodology to relate local strain to microstructural texture. Rev Sci Instrum 81:083703.  https://doi.org/10.1063/1.3474902 CrossRefGoogle Scholar
  31. 31.
    Nolze G (2007) Image distortions in SEM and their influences on EBSD measurements. Ultramicroscopy 107:172–183.  https://doi.org/10.1016/j.ultramic.2006.07.003 CrossRefGoogle Scholar
  32. 32.
    Pilchak AL, Shiveley AR, Tiley JS, Ballard DL (2011) AnyStitch: a tool for combining electron backscatter diffraction data sets. J Microsc 244:38–44.  https://doi.org/10.1111/j.1365-2818.2011.03496.x CrossRefGoogle Scholar
  33. 33.
    Pilchak AL, Shiveley AR, Shade PA et al (2012) Using cross-correlation for automated stitching of two-dimensional multi-tile electron backscatter diffraction data. J Microsc 248:172–186.  https://doi.org/10.1111/j.1365-2818.2012.03661.x CrossRefGoogle Scholar
  34. 34.
    Rowenhorst DJ (2013) Removing imaging distortions through automatic stitching of EBSD mosaics. Microsc Microanal 19:840–841.  https://doi.org/10.1017/S1431927613006193 CrossRefGoogle Scholar
  35. 35.
    Vic-2D 6, Correlated Solutions, Inc., Irmo, SCGoogle Scholar
  36. 36.
    Jiang R, Pierron F, Octaviani S, Reed PAS (2017) Characterisation of strain localisation processes during fatigue crack initiation and early crack propagation by SEM-DIC in an advanced disc alloy. Mater Sci Eng A 699:128–144.  https://doi.org/10.1016/j.msea.2017.05.091 CrossRefGoogle Scholar
  37. 37.
    Lewis JP (1995) Fast normalized cross-correlation. Vis Interface 95:120–123Google Scholar
  38. 38.
    Guizar-Sicairos M, Thurman ST, Fienup JR (2008) Efficient subpixel image registration algorithms. Opt Lett 33:156–158CrossRefGoogle Scholar

Copyright information