Advertisement

Sleep and Breathing

, Volume 7, Issue 2, pp 87–93 | Cite as

Nasal Breathing and Continuous Positive Airway Pressure (CPAP) in Patients with Obstructive Sleep Apnea (OSA)

  • Jan H. Hollandt
  • Malte Mahlerwein
Original Article

Abstract

Although nasal continuous positive airway pressure (nCPAP) treatment is the most efficient therapy for obstructive sleep apnea (OSA), compliance with therapy is poor because of several side effects. Among these adverse effects some are related to the reactions of the nose to nCPAP which are briefly described. In a long-term survey of 109 OSA patients, 80.6% continued nCPAP for at least 3 years until the last follow-up. Follow-up ranged between 0.8 and 109 months with a mean time of 43 (SD ± 24.7) months. Among all patients treated with nCPAP, only 46.6% met our criteria for long-term compliance, defined as a mean use of the CPAP machine for at least 5 hours per night. Within the objective measures such as age, body mass index, neck circumference, nasal airflow, apnea-hypopnea index, minimal oxygen saturation, and level of nCPAP pressure, no predictive factor for daily use of nCPAP could be found. However, pretherapeutic daytime somnolence (measured by visual analogue scale and Epworth Sleepiness Scale) and its improvement obtained from the therapy showed a significant effect on the daily use of the CPAP machine.

Keywords

Sleep apnea continuous positive airway pressure side effects nasal resistance 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Sullivan CE, Berthon-Jones M, Issa FG, EversL. Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares. Lancet 1981;1:862–865Google Scholar
  2. 2.
    Jenkinson C, DaviesRJO, Stradling JR. Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnea: a randomized prospective parallel trial. Lancet 1999;353:2100–2105CrossRefPubMedGoogle Scholar
  3. 3.
    Ballester E, Badia JR, HernandezL, et al. Evidence of effectiveness of continuous positive airway pressure in the treatment of sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 1999;159:495–501PubMedGoogle Scholar
  4. 4.
    Brandenburg U, Weiner M, Becker J, et al. Haemodynamics and sleep structure in the discontinued nCPAP test in obstructive sleep apnoea syndrome [German]. Pneumologie 1993;47:181–183Google Scholar
  5. 5.
    Krieger J, Weitzenblum E, Monassier JP, StoeckelC, Kurtz D. Dangerous hypoxemia during continuous positive airway pressure treatment of obstructive sleep apnea [letter]. Lancet 1983;2:1429–1430Google Scholar
  6. 6.
    Anderson AP, Alving J, Lildholdt T, Wulff C. Obstructive sleep apnea initiated by a lax epiglottis: a contraindication for continuous positive airway pressure. Chest 1987;91:621–623Google Scholar
  7. 7.
    Pépin JL, Leger P, Veale D, et al. Side effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers. Chest 1995;107:375–381Google Scholar
  8. 8.
    Strumpf DA, Harrop P, Dobbin J, MillmanRP. Massive epistaxis from nasal CPAP therapy. Chest 1989;95:1141–1141Google Scholar
  9. 9.
    Jarjour NN, Wilson P. Pneumocephalus associated with nasal continuous positive airway pressure in a patient with sleep apnea syndrome. Chest 1989;96:1425–1426Google Scholar
  10. 10.
    Bamford CR, Quan SF. Bacterial meningitis—a possible complication of nasal continuous positive airway pressure therapy in a patient with obstructive sleep apnea syndrome and a mucocele. Sleep 1993;16:31–32Google Scholar
  11. 11.
    Zwacka G, Scholle S, Kemper G, Rieger B. Nasal CPAP therapy for infants with congenital stridor. Sleep Breath 1997/98;2:085–096Google Scholar
  12. 12.
    Loftus BC, Ahn J, Haddad J. Neonatal nasal deformities secondary to nasal continuous positive airway pressure. Laryngoscope 1994;104:1019–1022Google Scholar
  13. 13.
    Mortimore IL, Whittle AT, Douglas NJ. Comparison of nose and face mask CPAP therapy for sleep apnoea. Thorax 1998;53:290–292Google Scholar
  14. 14.
    Verse T. Nebenwirkungen der nasalen CPAP-Ventilationstherapie. HNO 2000;48:706–715Google Scholar
  15. 15.
    Verse T, Lehnhardt E, Pirsig W, Junge-Hülsing B, Kroker B. Otorhinolaryngological side effects of nocturnal nasal ventilation therapy with continuous positive airway pressure (nCPAP). Laryngorhinootologie 1999;78:491–496Google Scholar
  16. 16.
    Wiest GH, Ficker JH, Müller A, HahnEG. Nebenwirkungen der nCPAP-Therapie beim obstruktiven Schlafapnoesyndrom. Ursachen und Therapie. Atemw-Lungenkrkh 1998;24:95–102Google Scholar
  17. 17.
    Lojander J, Brander PE, ÄmmäläK. Nasopharyngeal symptoms and nasal continuous positive airway pressure therapy in obstructive sleep apnea syndrome. Acta Otolaryngol 1999;119:497–502Google Scholar
  18. 18.
    Kalan A, Kenyon GS, Seemungal TAR, WedzichaA. Adverse effects of positive airway pressure therapy in sleep apnoea syndrome. J Laryngol Otol 1999;113:888–892Google Scholar
  19. 19.
    Nino-Murcia G, McCann CC, Bliwise DL, Guilleminault C, DementWC. Compliance and side effects in sleep apnea patients treated with nasal continuous positive airway pressure. West J Med 1989;150:165–169Google Scholar
  20. 20.
    Togias AG, Naclerio RM, Proud D, et al. Nasal challenge with cold, dry air results in release of inflammatory mediators: possible mast cell involvement. J Clin Invest 1985;76:1375–1381Google Scholar
  21. 21.
    Constantinidis J, Knöbber D, Steinhart H, Kuhn J, Iro H. Fine-structural investigations of the effect of nCPAP-mask application on the nasal mucosa. Acta Otolaryngol 2000;120:432–437Google Scholar
  22. 22.
    Richards GN, Cistulli PA, Ungar RG, Berthon-Jones M, SullivanCE. Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance. Am J Respir Crit Med 1996;154:182–186Google Scholar
  23. 23.
    Becker H, Fett I, Nees E, Peter JH, von WichertP. Behandlung primärer und sekundärer Therapieversager der nCPAP-Behandlung bei Patienten mit Schlafapnoe. Pneumologie 1991;45:301–305Google Scholar
  24. 24.
    Wiest GH, Lehnert G, BrückWM, et al. A heated humidifier reduces upper airway dryness during continuous positive airway pressure therapy. Resp Med 1999;93:21–26Google Scholar
  25. 25.
    Grunstein RR. Sleep-related breathing disorders. 5. Nasal continuous positive airway pressure treatment for obstructive sleep apnea. Thorax 1995;50:1106–1113Google Scholar
  26. 26.
    Coppola MP. Controversies in sleep medicine—essay: The Emperor (and my patient) has no nose. Sleep Breath 1999;3:107–107Google Scholar
  27. 27.
    Massie CA, Hart RW, Peralez K, RichardsGN. Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure. Chest 1999;116:403–408Google Scholar
  28. 28.
    Krieger J, Kurtz D. Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome. Eur Respir J 1988;1:436–438Google Scholar
  29. 29.
    Waldhorn RE, Herrick TW, Nguyen MC, et al. Long-term compliance with nasal continuous positive airway pressure therapy of obstructive sleep apnea. Chest 1990;97:33–38Google Scholar
  30. 30.
    Rauscher H, Popp W, Wanke T, Zwick H. Acceptance of CPAP therapy for sleep apnea. Chest 1991;100:1019–1023Google Scholar
  31. 31.
    Hoffstein V, Viner S, Mateika S, Conway J. Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects. Am Rev Respir Dis 1992;145:841–845Google Scholar
  32. 32.
    Engleman HM, Martin SE, Douglas NJ. Compliance with CPAP-therapy in patients with sleep apnea/hypopnea syndrome. Thorax 1994;49:263–266Google Scholar
  33. 33.
    Hollandt JH, Kuhl S, Siegert R. Treatment of patients with the obstructive sleep apnoea syndrome (OSAS) using nasal continuous positive airway pressure (nCPAP). Part I: Long-term compliance with nCPAP. Laryngorhinootologie 1997;76:550–553PubMedGoogle Scholar
  34. 34.
    Partinen M, Jamieson A, Guilleminault C. Long-term outcome for obstructive sleep apnea syndrome patients’ mortality. Chest 1988;94:1200–1204Google Scholar
  35. 35.
    Rasche K, Orth M, Duchna HW, Ullrich HW, Schultze-WerninghausG. CPAP-Therapie bei obstruktivem Schlafapnoesyndrom: Nebenwirkungen und Akzeptanz im Langzeitverlauf. Med Klinik 1994;89:86–88Google Scholar
  36. 36.
    Kuhl S, Hollandt JH, SiegertR. Treatment of patients with obstructive sleep apnea syndrome (OSAS) with nasal continuous positive airway pressure (nCPAP). Part II: Side effects of nCPAP therapy—influence on long-term compliance. Laryngorhinootologie 1997;76:608–613Google Scholar
  37. 37.
    Hollandt JH, Mahlerwein M, Klaiber S, Siegert R. Langzeitakzeptanz von nCPAP (nasal continuous positive airway pressure) bei Patienten mit obstruktivem Schlafapnoe Syndrom [abstract]. HNO Informationen 2002;27:136–136Google Scholar
  38. 38.
    Johns MW. Reliability and factor analysis of the Epworth Sleepiness Scale. Sleep 1992;15:376–381Google Scholar
  39. 39.
    Meurice JC, Dore P, Paquereau J, et al. Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in sleep apnea syndrome. Chest 1994;105:429–433Google Scholar
  40. 40.
    Mayer-Brix J, Becker H, PeterJH. Nasal high pressure ventilation in obstructive sleep apnea syndrome. Theoretical and practical otorhinolaryngological aspects [German]. Laryngorhinootologie 1989;68:295–298Google Scholar
  41. 41.
    Sériès F; Pierre SS, Carrier G. Effects of surgical correction of nasal obstruction in the treatment of obstructive sleep apnea. Am Rev Respir Dis 1992;146:1261–1265Google Scholar
  42. 42.
    Ripberger R, Pirsig W. Long-term compliance with nasal CPAP treatment for obstructive sleep apnoea: prospective study in 50 patients [German]. Laryngorhinootologie 1994;73:581–585Google Scholar
  43. 43.
    Friedmann M, Tanyeri H, Lim JW, et al. Effects of improved nasal breathing on obstructive sleep apnea. Otolaryngol Head Neck Surg 2000;122:71–74Google Scholar
  44. 44.
    Biermann E. Nasal CPAP-therapy in obstructive sleep apnea syndrome: does functional rhinosurgery improve compliance?. Somnologie 2001;5:59–64Google Scholar
  45. 45.
    Dorn M, Pirsig W, Verse T. Management of patients with severe obstructive sleep apnea following rhinosurgical interventions. A pilot study. HNO 2001;49:642–645Google Scholar

Copyright information

© Thieme Medical Publishers, Inc. 2003

Authors and Affiliations

  • Jan H. Hollandt
    • 1
  • Malte Mahlerwein
    • 1
  1. 1.Klinik für Hals-, Nasen- und OhrenheilkundeUniversitätsklinikum Schleswig-HolsteinCampus LübeckGermany

Personalised recommendations