Advertisement

Springer Nature is making SARS-CoV-2 and COVID-19 research free. View research | View latest news | Sign up for updates

Interaction of Hyaluronic Acid with CoCr Alloy Under Immersion and Wear–Corrosion Processes

Abstract

In this work, electrochemical and chemical changes induced by immersion and wear–corrosion processes of CoCr/CoCr couple in phosphate buffer solution (PBS) with 0.3% hyaluronic acid (PBS-HA) have been studied. Electrochemical characterization of CoCr surfaces in PBS-HA was performed by the measurement of the corrosion potential, electrochemical impedance spectroscopy, and scanning kelvin probe. Wear–corrosion tests were carried out in PBS-HA in a pin-on disk tribometer where 5N was loaded on the CoCr cylindrical pin in contact with CoCr disk rotating at 120 rpm of 10 mm diameter. Chemical composition of the CoCr surfaces after wear–corrosion tests was assessed by X-ray photoelectron spectroscopy (XPS). The electrochemical results on CoCr surfaces in hyaluronic acid solution revealed that the hyaluronic acid accelerates the formation of a stable and resistant passive film on the CoCr surfaces after few hours of immersion. XPS results showed that continuous sliding under immersion in PBS-HA causes the loss of the Cr oxides [forming preferentially Cr(OH)3] and a slight increase in Co(II) species in the passive film. These changes in the chemical composition were accompanied by the increase, at least twofold, in C and O and calcium phosphate compounds on the outer CoCr surfaces.

This is a preview of subscription content, log in to check access.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

References

  1. 1.

    DesJardins, J., Aurora, A., Tanner, S.L., Pace, T.B., Acampora, K.B., LaBerge, M.: Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant. Proc. Inst. Mech. Eng. H. 220, 609–623 (2006)

  2. 2.

    Uesaka, S., Miyazaki, K., Ito, H.: Age-related changes and sex differences in chondroitin sulfate isomers and hyaluronic acid in normal synovial fluid. Mod. Rheumatol. 14, 470–475 (2004)

  3. 3.

    Hills, B.A., Butler, B.D.: Surfactants Identified in Synovial Fluid and Their Ability to Act as Boundary Lubricants. Ann. Rheum. Dis. 43, 641–648 (1984)

  4. 4.

    Lewis, A.C., Kilburn, M.R., Papageorgiou, I.: The effect of synovial fluid, phosphate buffered saline solution and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopaedic implants. J Biomed Mater Res 73A, 456–467 (2005)

  5. 5.

    Yan, Y., Neville, A., Dowson, D., Williams, S., Fisher, J.: Tribofilm formation in biotribocorrosion—does it regulate ion release in metal-on-metal artificial hip joints? Proc. Inst. Mech. Eng. J. 224, 997–1006 (2010)

  6. 6.

    Parkes, M., Myant, C., Cann, P.M., Wong, J.S.S.: Synovial Fluid Lubrication: The Effect of Protein Interactions on Adsorbed and Lubricating Films. Biotribology 1–2, 51–60 (2015)

  7. 7.

    Marques, M.R.C., Loebenberg, R., Almukainzi, M.: Simulated Biological Fluids with Possible Application in Dissolution Testing. Dissolut. Technol. 31, 15–28 (2011)

  8. 8.

    Liao, Y., Hoffman, E., Wimmer, M., Fischer, A., Jacobs, J., Marks, L.: CoCrMo metal-on-metal hip replacements. Phys. Chem. Chem. Phys. 15, 746–756 (2013)

  9. 9.

    Burbano, M., Russell, R., Huo, M., Welch, R., Roy, D., Rodrigues, D.C.: Surface characterization of retrieved metal-on-metal total hip implants from patients with adverse reaction to metal debris. Materials 7, 1866–1879 (2014)

  10. 10.

    Wimmer, M.A., Fischer, A., Buscher, R., Pourzal, R., Sprecher, C., Hauert, R., Jacobs, J.J.: Wear mechanisms in Metal-on-Metal Bearings: The importance of tribochemical reaction layers. J. Orthop. Res. 28, 436–443 (2010)

  11. 11.

    Wimmer, M.A., Sprecheer, C., Hauert, R., Täger, G., Fisher, A.: Tribochemical reaction on metal-on-metal hip joint bearings. A comparison between in vitro e in vivo results. Wear 255, 1007–1014 (2003)

  12. 12.

    Brown, S.S., Clarke, I.C.: A Review of Lubrication conditions for Wear Simulation in Artificial Hip Replacements. Tribol. Trans. 49, 72–78 (2006)

  13. 13.

    Duff-Barclay, I., Spillman, D.T.: Paper 10: total human hip joint prostheses—a laboratory study of friction and wear. Proc. Inst. Mech. Eng. H. 181, 90–103 (1966)

  14. 14.

    Gomez-Barrena, E.: CORR Insights1: revision of metal-on-metal hip prostheses results in marked reduction of blood cobalt and chromium ion concentrations. Clin. Orthop. Relat. Res. 473, 2314–2315 (2015)

  15. 15.

    Scientific Committee on Emerging and Newly Identified Health Risks. The safety of Metal-on-Metal joint replacements with a particular focus on hip implants, 24 February 2014. ISBN 978-92-79-30135-3. https://ec.europa.eu/health/scientific_committees/emerging/docs/scenihr_o_042.pdf. Accessed February 2014

  16. 16.

    Hui, A.Y., McCarty, W.J., Masuda, K., Firestein, G.S., Sah, R.L.: A systems biology approach to synovial joint lubrication in health, injury, and disease. Rev. Syst. Biol. Med. 4, 15–37 (2012)

  17. 17.

    Wagner, C.D., Davis, L.E., Zeller, M.V., Taylor, J.A., Raymond, R.M., Gale, L.H.: Empirical atomic sensitivity factors for quantitative analysis by electron spectroscopy for chemical analysis. Surf. Interface Anal. 3, 211–225 (1981)

  18. 18.

    Brug, G.J., van den Eeden, A.L.G., Sluyters-Rehbach, M., Sluyters, J.H.: The Analysis of Electrode Impedances Complicated by the Presence of aConstant Phase Element. J. Electroanal.Chem. 176, 275–295 (1984)

  19. 19.

    Igual-Muñoz, A., Mischler, S.: Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys. J. Mater. Sci. Mater. Med. 22, 437–450 (2011)

  20. 20.

    Wang, Z., Yan, Y., Su, Y., Qiao, L.: Effect of proteins on the surface microstructure evolution of a CoCrMo alloy in bio-tribocorrosion processes. Colloids Surf. B 145, 176–184 (2016)

  21. 21.

    Milosev, I.: The effect of biomolecules on the behaviour of CoCrMo alloy in various simulated physiological solutions. Electrochim. Acta 78, 259–273 (2012)

  22. 22.

    Hanawa, T., Hiromoto, S., Asami, K.: Characterization of the surface oxide film of a Co-Cr-Mo alloy after being located in quasi-biological environments using XPS. Appl. Surf. Sci. 183, 68–75 (2001)

  23. 23.

    Li, Y.-S., Wang, K., He, P., Huang, B.X., Kovacs, P.: Surface-enhanced Raman Spectroelectrochemical studies of corrosion films on implant CoCr alloy in biosimulating solution. J. Raman Spectrosc 30, 97–103 (1999)

  24. 24.

    Bautista, A., Blanco, G., Velasco, F., Gutiérrez, A., Soriano, L., Palomares, F.J., Takenouti, H.: Changes in the passive layer of corrugated austenitic stainless steel of low nickel content due to exposure to simulated pore solutions. Corros. Sci. 51, 785–792 (2009)

  25. 25.

    Hedberg, Y., Karlsson, M.E., Wei, Z., Znidarsic, M., Odnevall Wallinder, I., Hedberg, J.: Interaction of albumin and fibrinogen with stainless steel: influence of sequential exposure and protein aggregation on metal release and corrosion resistance. Corrosion 73, 1423–1436 (2017)

  26. 26.

    Lewis, A.C., Kilburn, M.R., Heard, P.J., Scott, T.B., Hallam, K.R., Allen, G.C., Learmonth, I.D.: The entrapment of corrosion products from CoCr implant alloys in the deposits of calcium phosphate: a comparison of serum, synovial fluid, albumin, EDTA, and water. J. Orthop. Res. 24, 1587–1596 (2006)

  27. 27.

    Balogh, G.T., Illes, J., Szekely, Z., Forrai, E., Gere, A.: Effect of different metal ions on the oxidative damage and antioxidant capacity of hyaluronic acid. Arch. Biochem. Biophys. 410, 76–82 (2003)

  28. 28.

    Miyazaki, T., Yomota, C., Okada, S.: Degradation of hyaluronic acid at the metal Surface. Colloid Polym Sci 276, 388–394 (1998)

  29. 29.

    Tsutsumi, Y., Nishimura, D., Doi, H., Nomura, H., Hanawa, T.: Difference in surface reactions between titanium and zirconium in Hank’s solution to elucidate mechanism of calcium phosphate formation on titanium using XPS and cathodic polarization. Mater. Sci. Eng. C Mater. Biol. Appl. 29, 1702–1708 (2009)

  30. 30.

    Burgos-Asperilla, L., García-Alonso, M.C., Escudero, M.L., Alonso, C.: Study of the interaction of inorganic and organic compounds of cell culture medium with a Ti Surface. Acta Biomater 6, 652–661 (2010)

  31. 31.

    Ellingsen, J.E.: A study on the mechanism of protein adsorption to TiO2. Biomaterials 12, 593–596 (1991)

  32. 32.

    Wu, T.T., Gan, X.Q., Cai, Z.B., Zhu, M.H., Qiao, M.T., Yu, H.Y.: The lubrication effect of hyaluronic acid and chondroitin sulfate on the natural temporomandibular cartilage under torsional fretting wear. Lubr. Sci. 27, 29–44 (2015)

  33. 33.

    Yan, Y., Neville, A., Dowson, D.: Biotribocorrosion of CoCrMo orthopaedic implant materials-Assessing the formation and effect of the biofilm. Tribol. Int. 40, 1492–1499 (2007)

Download references

Acknowledgements

This work was supported by the Spanish National government MINECO-MAT2011-29152-C02-01 and MAT2015-67750-C3-1.

Author information

Correspondence to M. C. García-Alonso.

Rights and permissions

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

García-Alonso, M.C., Llorente, I., Díaz, I. et al. Interaction of Hyaluronic Acid with CoCr Alloy Under Immersion and Wear–Corrosion Processes. Tribol Lett 66, 122 (2018). https://doi.org/10.1007/s11249-018-1073-3

Download citation

Keywords

  • Hyaluronic acid
  • CoCr
  • Wear corrosion
  • Metal on Metal