Bivalirudin for left ventricular assist device thrombosis

  • Phillip Weeks
  • Adam Sieg
  • Indranee Rajapreyar
  • Sriram Nathan
  • Marwan Jumean
  • Manish Patel
  • Rajko Radovancevic
  • Biswajit Kar
  • Igor Gregoric
Article

Abstract

Pump thrombosis remains a serious complication of implantable ventricular assist device therapy and is associated with increased risk of morbidity and mortality. Optimal management strategies remain controversial and are guided largely by limited literature and expert opinion. Medical management of pump thrombosis, including the use of direct thrombin inhibitors, has been associated with mixed results. The purpose of this study is to report the outcomes associated with bivalirudin therapy in LVAD patients with suspected pump thrombosis. A single-center, retrospective observational study of 15 patients with suspected pump thrombosis that were all treated with bivalirudin therapy was conducted. The majority of subjects’ initial treatment courses were unsuccessful [9/15 (60%)]; however, 6/15 (40%) achieved an initial improvement in serum lactate dehydrogenase (LDH) levels and were stabilized to be successfully discharged from the hospital. Of the subjects discharged, there was a high rate of recurrence of pump thrombosis within 6 months [5/6 (83.3%)]. Bivalirudin therapy was not associated with a consistent reduction in LDH among all subjects studied, and clinical responses to therapy appear to be associated with high rates of thrombosis recurrence. This study analyzes the largest cohort to date of LVAD patients with pump thrombosis treated with bivalirudin therapy, and suggests that alternative therapies should be considered in management.

Keywords

Bivalirudin Direct thrombin inhibitor LVAD Thrombosis Pump thrombosis 

Notes

Acknowledgements

The investigators wish to acknowledge the dedication and hard work of the nurses, LVAD coordinators, advanced practice providers and all others involved in the care of LVAD patients of the Univeristy of Texas Health Science Center—Center for Advanced Heart Failure at Memorial Hermann—Texas Medical Center. In addition, thanks to R. Michelle Sauer Gehring, PhD, ELS, CRA for editorial support.

Funding

There was no outside source of funding for this study.

Compliance with ethical standards

Conflict of interest

The investigators/authors of this study declare that they have no conflict of interest.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

The need for informed consent was waived by the IRB due to the retrospective nature of the study being performed.

References

  1. 1.
    Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson LW, Blume ED et al (2015) Seventh INTERMACS annual report: 15,000 patients and counting. J Heart Lung Transplant 34:1495–1504CrossRefPubMedGoogle Scholar
  2. 2.
    Miller LW, Pagani FD, Russell SD, John R, Boyle AJ, Aaronson KD et al (2007) Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 357:885–896CrossRefPubMedGoogle Scholar
  3. 3.
    Slaughter MS, Pagani FD, McGee EC, Birks EJ, Cotts WG, Gregoric I et al (2013) HeartWare ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial. J Heart Lung Transplant 32:675–683CrossRefPubMedGoogle Scholar
  4. 4.
    Mehra MR, Naka Y, Uriel N, Goldstein DJ, Cleveland JC Jr, Colombo PC et al (2017) A fully magnetically levitated circulatory pump for advanced heart failure. N Engl J Med 376:440–450CrossRefPubMedGoogle Scholar
  5. 5.
    Feldman D, Pamboukian SV, Teuteberg JJ, Birks E, Lietz K, Moore SA et al (2013) The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary. J Heart Lung Transplant 32:157–187CrossRefPubMedGoogle Scholar
  6. 6.
    Slaughter MS, Pagani FD, Rogers JG, Miller LW, Sun B, Russell SD et al (2010) Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant 29:S1–S39CrossRefPubMedGoogle Scholar
  7. 7.
    Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Myers S, Acker MA et al (2015) Pump thrombosis in the Thoratec HeartMate II device: an update analysis of the INTERMACS registry. J Heart Lung Transplant 34:1515–1526CrossRefPubMedGoogle Scholar
  8. 8.
    Starling RC, Moazami N, Silvestry SC, Ewald G, Rogers JG, Milano CA et al (2014) Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med 370:33–40CrossRefPubMedGoogle Scholar
  9. 9.
    Goldstein DJ, John R, Salerno C, Silvestry S, Moazami N, Horstmanshof D et al (2013) Algorithm for the diagnosis and management of suspected pump thrombus. J Heart Lung Transplant 32:667–670CrossRefPubMedGoogle Scholar
  10. 10.
    Samuels LE, Kohout J, Casanova-Ghosh E, Hagan K, Garwood P, Ferdinand F et al (2008) Argatroban as a primary or secondary postoperative anticoagulant in patients implanted with ventricular assist devices. Ann Thorac Surg 85:1651–1655CrossRefPubMedGoogle Scholar
  11. 11.
    Badiye A, Hernandez GA, Chaparro S (2014) Argatroban as novel therapy for suspected thrombosis in patients with continuous-flow left ventricle assist device and hemolysis. ASAIO J 60:361–365CrossRefPubMedGoogle Scholar
  12. 12.
    Sarsam SH, Civitello AB, Agunanne EE, Delgado RM (2013) Bivalirudin for treatment of aortic valve thrombosis after left ventricular assist device implantation. ASAIO J 59:448–449CrossRefPubMedGoogle Scholar
  13. 13.
    Sylvia LM, Ordway L, Pham DT, DeNofrio D, Kiernan M (2014) Bivalirudin for treatment of LVAD thrombosis: a case series. ASAIO J 60:744–747CrossRefPubMedGoogle Scholar
  14. 14.
    Rimsans J, Sylvester KW, Connors JM (2017) Direct thrombin inhibitor for LVAD thrombosis: a closer look. Clin Appl Thromb Hemost 23:405–409CrossRefPubMedGoogle Scholar
  15. 15.
    Rosendaal FR, Cannegieter SC, van der Meer FJ, Briet E (1993) A method to determine the optimal intensity of oral anticoagulant therapy. Thromb Haemost 69:236–239CrossRefPubMedGoogle Scholar
  16. 16.
    Dang G, Epperla N, Muppidi V, Sahr N, Pan A, Simpson P et al (2017) Medical management of pump-related thrombosis in patients with continuous-flow left ventricular assist devices: a systematic review and meta-analysis. ASAIO J 63:373–385CrossRefPubMedPubMedCentralGoogle Scholar
  17. 17.
    Hohner E, Crow J, Moranville MP (2015) Medication management for left ventricular assist device thrombosis. Am J Health Syst Pharm 72:1104–1113CrossRefPubMedGoogle Scholar
  18. 18.
    Jennings DL, Weeks PA (2015) Thrombosis in continuous-flow left ventricular assist devices: pathophysiology, prevention, and pharmacologic management. Pharmacotherapy 35:79–98CrossRefPubMedGoogle Scholar
  19. 19.
    Luc JGY, Tchantchaleishvili V, Phan K, Dunlay SM, Maltais S, Stulak JM (2018) Medical therapy compared with surgical device exchange for left ventricular assist device thrombosis: a systematic review and meta-analysis. ASAIO J.  https://doi.org/10.1097/MAT.0000000000000833 (Epub ahead of print)CrossRefPubMedGoogle Scholar
  20. 20.
    Zucker ML, Koster A, Prats J, Laduca FM (2005) Sensitivity of a modified ACT test to levels of bivalirudin used during cardiac surgery. J Extra Corpor Technol 37:364–368PubMedPubMedCentralGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Department of PharmacyMemorial Hermann – Texas Medical CenterHoustonUSA
  2. 2.University of Kentucky HealthcareLexingtonUSA
  3. 3.University of Alabama BirminghamBirminghamUSA
  4. 4.Center for Advanced Heart FailureUniversity of Texas Health Science CenterHoustonUSA

Personalised recommendations