Advertisement

Pharmaceutical Chemistry Journal

, Volume 52, Issue 10, pp 868–872 | Cite as

Quality Control Method for 111In-Oxine Radiopharmaceutical Composition

  • N. A. TaratonenkovaEmail author
  • E. A. Lyamtseva
  • A. O. Malysheva
  • G. E. Kodina
STRUCTURE OF CHEMICAL COMPOUNDS, METHODS OF ANALYSIS AND PROCESS CONTROL
  • 29 Downloads

A search for a modern method to determine the radiochemical purity of an 111In-oxine radiopharmaceutical composition resulted in the selection of a chromatography system that could perform quality control rapidly, consistently, and more accurately than an extraction method. The simplicity of the method made it accessible and convenient for performing quality control in medical institutions immediately before labeling leukocytes and stem cells.

Keywords

Reoxind-111In indium-111 oxine RP radiochemical purity 

References

  1. 1.
    I. O. Tomashevskii, L. D. Soshin, A. I. Luchshev, et al., Radiol.-prakt., 2, 40 – 42 (2004).Google Scholar
  2. 2.
    M. Roca, E. F. J. de Vries, F. Jamar, et al., Eur. J. Nucl. Med. Mol. Imaging, 37(4), 835 – 841 (2010).CrossRefGoogle Scholar
  3. 3.
    J. P. Horcajada, M. Gutierrez-Cuadra, I. Martinez-Rodriguez, et al., Eur. J. Clin. Microbiol., 31(3), 237 – 242 (2012).CrossRefGoogle Scholar
  4. 4.
    R. D. Dhekne, S. N. Chatziioannou, W. H. Moore, et al., Am. J. Gastroenterol., 95(8), 1983 – 1989 (2000).CrossRefGoogle Scholar
  5. 5.
    K. Takahashi, M. Ohyanagi, K. Ikeoka, et al., J. Nucl. Cardiol., 8(2), 165 – 170 (2001).CrossRefGoogle Scholar
  6. 6.
    A. V. Meleshina, E. I. Cherkasova, M. V. Shirmanova, et al., Sovrem. Tekhnol. Med., 7(4), 174 – 188 (2015).CrossRefGoogle Scholar
  7. 7.
    G. E. Kodina, E. A. Lyamtseva, A. O. Malysheva, et al., in: Abstracts of Papers of the VIth Troitsk Conference on Medical Physics and Innovation in Medicine [in Russian], Troitsk (2014), pp. 679 – 680.Google Scholar
  8. 8.
    US Pharmacopoeia, USP 38, USP Monograph “Indium In-111 Oxyquinoline Solution” (2016).Google Scholar
  9. 9.
    G. E. Kodina, E. A. Lyamtseva, A. O. Malysheva, et al., in: Abstracts of Papers of the International Scientific-Practical Conference RADIOFARMA-2015 [in Russian], Moscow (2015), p. 44.Google Scholar
  10. 10.
    European Pharmacopoeia 8.0 (vol. 1), Monograph “Indium (111In) Oxine Solution” (2014), p. 1066.Google Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2019