Advertisement

Measurement Techniques

, Volume 61, Issue 8, pp 791–796 | Cite as

Onboard Hydrogen Frequency Standard for the Millimetron Space Observatory

  • N. A. Demidov
  • A. A. Belyaev
  • V. A. Polyakov
  • Yu. V. Timofeev
Article
  • 7 Downloads

The basic structural features of a hydrogen frequency standard designed to work as a reference frequency standard under the conditions of outer space are described. The capabilities gained from the use of a system of double selection of hydrogen atoms by energy state to increase the metrological characteristics of the hydrogen frequency standard are considered. Experimental results on frequency instability are presented

Keywords

onboard active hydrogen frequency standard double system for selecting atoms by quantum state adiabatic rapid passage frequency instability 

References

  1. 1.
    A. Belyaev, A. Biriukov, N. Demidov, L. Likhacheva, S. Medvedev, A. Myasnikov, Y. Pavlenko, B. Sakharov, P. Smirnov, E. Storojev, and A. Tulyakov, “Russian hydrogen masers for space applications,” in: Proc. PTTI, Washington, Dec. 2–3, 2013, pp. 87–93.Google Scholar
  2. 2.
    V. G. Vorontsov, N. A. Demidov, and A. A. Belyaev, “Development of a new model of a hydrogen generator with the use of the ANR system by the method of resonator frequency switching,” in: Metrology of Time and Space: Proc. 6th Intern. Symposium, VNIIFTRI, Mendeleevo (2013), pp. 72–74.Google Scholar
  3. 3.
    K. Kleppner, N. M. Goldenberg, and N. F. Ramsey, “Theory of hydrogen maser,” Phys. Rev., 126, No. 2, 603–615 (1962), DOI:  https://doi.org/10.1103/physrev.126.603.ADSCrossRefGoogle Scholar
  4. 4.
    R. F. Vessot, “State of the art and future directions of the atomic hydrogen maser,” Proc. 22nd Precise Time and Time Interval (PTTI), Applications and Planning Meeting (1990).Google Scholar
  5. 5.
    A. Boyko, G. Yolkin, N. Gestkova, G. Kurnikov, and V. Paramzin, “Hydrogen maser with improved short-term frequency stability,” in: Proc. 15th Europ. Frequency and Time Forum, Swiss Foundation for Research in Microtechnology, Neuchatel, Switzerland (2001), pp. 406–408.Google Scholar
  6. 6.
    A. A. Belyaev, N. A. Demidov, V. A. Polyakov, and Yu. V. Timofeev, “Estimation of a possible decrease in the limiting frequency instability of a hydrogen generator with the use of a beam of atoms in a single quantum state,” Izmer. Tekhn., No. 8, 28–31 (2018).Google Scholar
  7. 7.
    V. A. Polyakov, A. A. Belyaev, N. A. Demidov, and Yu. V. Timofeev, “Mathematical simulation of a selection system of a beam of hydrogen atoms for the purpose of increasing the short-term frequency stability of a hydrogen generator,” Metrology of Time and Space: Proc. 6th Intern. Symposium, VNIIFTRI, Mendeleevo (2013), pp. 354–355.Google Scholar
  8. 8.
    E. M. Mattison, R. F. C. Vessot, and W. Shen, “Single-state selection system for hydrogen masers,” IEEE Trans. Ultrason., Ferroelectr. Freq. Control, 34, Iss. 6, 622–628 (1987).Google Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  • N. A. Demidov
    • 1
  • A. A. Belyaev
    • 1
  • V. A. Polyakov
    • 1
  • Yu. V. Timofeev
    • 1
  1. 1.Vremya-Ch CompanyNizhnii NovgorodRussia

Personalised recommendations