Advertisement

Investigation of energy and exergy performance on a small-scale refrigeration system with PCMs inserted between coil and wall of the evaporator cabin

  • M. Antony Forster Raj
  • S. Joseph Sekhar
Article
  • 16 Downloads

Abstract

Domestic refrigerators have become an indispensable part of the modern life. Since they are connected to the electric mains and operate throughout the day and year, they consume a lot of energy. Several experimental studies show that the addition of phase change material in the refrigerators at various locations improves the energy efficiency of the refrigerators. In this work, an experimental study was conducted to explore and reveal the improvement in energy efficiency of a small-scale refrigeration system when PCM was applied between the evaporator coil and the insulation. It was observed that the addition of PCM for a thickness of 0.03 m could reduce the heat ingress inside the evaporator by 15–19%. Moreover, the compressor ON cycle time and the temperature fluctuation inside the freezer cabinet were also relatively lesser. The per day energy consumption was reduced by 15.7–17.3% and the improvement in COP was found to be 17.4% with the addition of PCM. The refrigeration system was able to retain its desired temperature level for a period of 5 h even after the power supply was switched OFF. This idea of incorporating PCM between coil and insulation could be extended to household refrigerators so as to reduce the energy consumption. This would come handy in case of power outages which are very common in places having low grid reliability.

Keywords

Domestic refrigerator COP Exergy PCM Insulation Energy efficiency TEWI 

References

  1. 1.
    Liu D-Y, Chang W-R, Lin J-Y. Performance comparison with effect of door opening on variable and fixed frequency refrigerators/freezers. Appl Therm Eng. 2004;24:2281–92.CrossRefGoogle Scholar
  2. 2.
    McNeil, Michael A. Progress towards managing residential electricity demand: impacts of standards and labeling for refrigerators and air conditioners in India. In: 5th International conference on energy efficiency on domestic appliances and lighting. EEDAL, Berlin, Germany; 2009.Google Scholar
  3. 3.
    Marques AC, Davies GF, Evans JA, Maidment GG, Wood ID. Theoretical modelling and experimental investigation of a thermal energy storage refrigerator. Energy. 2013;55:457–65.CrossRefGoogle Scholar
  4. 4.
    Geppert J, Stamminger R. Analysis of effecting factors on domestic refrigerator’s energy consumption in use. Energy Convers Manag. 2013;76:794–800.CrossRefGoogle Scholar
  5. 5.
    Cheng WL, Mei BJ, Liu YN, Huang YH, Yuan XD. A novel household refrigerator with a shape-stabilized PCM (phase change material)heat storage condensers—an experimental investigation. Energy. 2011;36(10):5797–804.CrossRefGoogle Scholar
  6. 6.
    Joybari MM, Hatamipour MS, Rahimi A, Modarres FG. Exergy analysis and optimization of R 600a as a replacement of R134a in a domestic refrigerator system. Int J Refrig. 2013;36(4):1233–42.CrossRefGoogle Scholar
  7. 7.
    Ekren O, Celik S, Noble B, Krauss R. Performance evaluation of a variable speed DC compressor. Int J Refrig. 2013;36(3):745–57.CrossRefGoogle Scholar
  8. 8.
    Park YC. Transient analysis of a variable speed rotary compressor. Energy Convers Manag. 2010;51(2):277–87.CrossRefGoogle Scholar
  9. 9.
    Hammond E, Evans J. Application of vacuum insulated panels in the cold chain-analysis of viability. Int J Refrig. 2014;47:58–65.CrossRefGoogle Scholar
  10. 10.
    Khan MIH, Afroz HM. Effect of phase change material on a household refrigerator: Asian. J Appl Sci. 2013;6(2):56–67.Google Scholar
  11. 11.
    Roth P. Energy saving on the high pressure side of a refrigerating plant. KI. 2008;03:30–5.Google Scholar
  12. 12.
    Maltini E, Cortella G, Stecchini M, Deltorre M, Pittia P, Spaziani M, Mansutti G. Design and performances of a constant temperature compartment for domestic refrigerator. In: Proceedings of the 9th international congress on engineering and food, Montpellier, France. 7–11 March 2004.Google Scholar
  13. 13.
    Mastani M, Joybari FH, Moffat J, Sra P. Heat and cold storage using phase change materials in domestic refrigeration systems-The state-of-the-art review. Energy Build. 2015;106:111–24.CrossRefGoogle Scholar
  14. 14.
    Rahman R, Hossain MA, Das SK, Hasan A. Performance improvement of a domestic refrigerator by using PCM (phase change material). Glob J Res Eng. 2014;13(10):17–22.Google Scholar
  15. 15.
    Zalba B, Jose Marin M, Luisa Cabeza F, Mehling H. Review on thermal energy storage with phase change materials, heat transfer analysis and applications. Appl Therm Eng. 2003;23:251–83.CrossRefGoogle Scholar
  16. 16.
    Saidur R, Masjuki HH, Choudhury IA. Role of ambient temperature, door opening, thermostat setting position and their combined effect on refrigerator-freezer energy consumption. Energy Convers Manag. 2012;43:845–54.CrossRefGoogle Scholar
  17. 17.
    Yehya A, Naji H. A novel technique to analyze the effect of enclosure shape on the performance of phase-change materials. Energy Procedia. 2015;75:2131–6.CrossRefGoogle Scholar
  18. 18.
    Ahmed M, Meade O, Medina MA. Reducing heat transfer across the insulated walls of refrigerated truck trailers by the application of phase change materials. Energy Convers Manag. 2010;51(3):383–92.CrossRefGoogle Scholar
  19. 19.
    Azzouz K, Leducqa D, Gobinb D. Performance enhancement of a household refrigerator by addition of latent heat storage. Int J Refrig. 2008;31:892–901.CrossRefGoogle Scholar
  20. 20.
    Saji Raveendran P, Joseph Sekhar S. Experimental studies on domestic refrigeration system with brazed plate heat exchanger as condenser. J Mech Sci Technol. 2016;30(6):2865–71.CrossRefGoogle Scholar
  21. 21.
    Bayrakci HC, Ozgur AE. Energy and exergy analysis of vapour compression refrigeration system using pure hydrocarbon refrigerants. Int J Energy Res. 2009;33:1070–5.CrossRefGoogle Scholar
  22. 22.
    Gupta A, Anand Y, Anand S, Tyagi SK. Thermodynamic optimization and chemical exergy quantification for absorption-based refrigeration system. J Therm Anal Calorim. 2015;122(2):893–905.CrossRefGoogle Scholar
  23. 23.
    Saravanakumar R, Selladurai V. Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a. J Therm Anal Calorim. 2013;115(1):933–40.CrossRefGoogle Scholar
  24. 24.
    Davies TW, Caretta O. A low carbon, low TEWI refrigeration system design. Appl Therm Eng. 2004;24:1119–28.CrossRefGoogle Scholar
  25. 25.
    Holman JP. Experimental methods for engineers. 7th ed. New York: McGraw Hill Publishers; 2000.Google Scholar
  26. 26.
    Ezan MA, Doganay EO, Yavuz FE, HakkTavman I. A numerical study on the usage of phase change material (PCM) to prolong compressor off period in a beverage cooler. Energy Convers Manag. 2017;142:95–106.CrossRefGoogle Scholar

Copyright information

© Akadémiai Kiadó, Budapest, Hungary 2018

Authors and Affiliations

  1. 1.Department of Mechanical EngineeringSt. Xavier’s Catholic College of EngineeringNagercoilIndia

Personalised recommendations