A modified LED fluorimetry determination of uranium in Nb/Ta minerals has been developed. The mineral is brought into solution by fusion with mixed phosphate flux (NaH2PO4, H2O and Na2HPO4). Iron quenches uranium fluorescence when it is present above the ratio of (iron to uranium) 100. Uranium is separated in ethyl acetate by solvent extraction and then stripped back into pyrophosphate buffer (pH ~ 7) prior to its LED fluorimetry determination. This modified method has been applied for the determination of uranium in synthetic mixtures and Nb/Ta minerals including Certified Reference Materials (X1807) with high degree of accuracy and precision.

Keywords

Uranium Iron/uranium ratio Niobite–tantalite minerals LED fluorimetry 

Notes

Acknowledgements

The authors express their sincere thanks and gratitude to Directors, AMD, Hyderabad and NIT, Jamshedpur for their kind permission to do research work leading to Ph.D. The authors are also thankful to Regional Director and Dy. Regional Director, AMD, Eastern Region, Jamshedpur for providing necessary facilities to carry out the work. Also, the authors are thankful to Head, Chemistry Group, AMD, Hyderabad and Dr. Vijay Kumar, Incharge, Chemistry Laboratory, AMD, Jamshedpur for their constant encouragement, support and motivation to do the work. Special thanks to Shri Amit kumar, research scholar, NIT, Jamshedpur for his non-technical support.

References

  1. 1.
    Gupta CK, Suri AK (1994) Extractive metallurgy of niobium. CRC Press, Boca RatonGoogle Scholar
  2. 2.
    Onishi H (1989) Photometric determination of trace metals, part IIB. Wiley, New YorkGoogle Scholar
  3. 3.
    Chen X, Zhang K, Yu H, Yu L, Ge H, Yue J, Hou T, Asiri AM, Marwani HM, Wang S (2018) Sensitive and selective fluorescence detection of aqueous uranyl ions using water-soluble CdTe quantum dots. J Radioanal Nucl Chem 316:1011–1019Google Scholar
  4. 4.
    Chen X, Mei Q, Yu L, Ge H, Yue J, Zhang K, Hayat T, Alsaedi A, Wang S (2018) Rapid and on-site detection of uranyl ions via ratiometric fluorescence signals based on a smartphone platform. ACS Appl Mater Interfaces 10(49):42225–42232Google Scholar
  5. 5.
    Arora HC (2003) Chemical analysis of geological materials-theory and practice, 1st edn. A Publication of Chemistry Group, AMD/DAE, Govt. of India, Hyderabad, p 5Google Scholar
  6. 6.
    Satyanarayana K, Nayeem MA (2002) Application of solvent extraction and acid hydrolysis of Nb/Ta separation methods for the determination of uranium in geological materials, Nb/Ta-type samples, and leach liquors by ICP-OES. Atom Spectrosc 23(3):77–85Google Scholar
  7. 7.
    Balaji BK, Premadas A, Ramanaiah GV (1984) Estimation of uranium in columbite–tantalite samples: a method for sample solution preparation for fluorimetric estimation. Talanta 31(10):846–847Google Scholar
  8. 8.
    Premadas A, Hanuman VV, Dwivedi VN (2004) Chemical characterization of columbite tantalite minerals by ICP-OES and FAAS. Atom Spectrosc 25(2):70–78Google Scholar
  9. 9.
    Radhamani R, Mahanta PL, Murugasan P, Chakrapani G (2010) Novel fusion method for direct determination of uranium in ilmenite, rutile, columbite, tantalite and xenotime minerals by laser induced fluorimetry. J Radioanal Nucl Chem 285:287–292Google Scholar
  10. 10.
    Tarafder PK, Ghosh PK, Pradhan SK (2017) A novel approach for trace to percentage level determination of uranium in rocks, soils and stream sediments by laser induced fluorimetry (LIF). J Radioanal Nucl Chem 313(2):353–360Google Scholar
  11. 11.
    Campen W, Bachman K (1979) Laser induced fluorescence for the direct determination of small concentration of uranium in water. Mikrochim Acta II 72(3):159–170Google Scholar
  12. 12.
    Zook AC, Collins LH, Pietri CE (1981) Determination of nanogram quantities of uranium by pulsed laser fluorimetry. Mikrochim Acta II 76(5):457–468Google Scholar
  13. 13.
    Kumar M, Krishnakumar M (2017) A manual on fluorimetric determination of uranium in geo-materials. A Publication of Chemistry Group, AMD/DAE, Govt. of India, HyderabadGoogle Scholar
  14. 14.
    Longmuir D (1978) Uranium solution–mineral equilibria at low temperature with applications to sedimentary ore deposits. Geochimica et Cosmochimica Acta Part A 42(6):547–569Google Scholar
  15. 15.
    Saghatehi H, Ansari R, Mousavi HZ (2018) Highly efficient adsorptive removal of uranyl ions from aqueous solutions using dicalcium phosphate nanoparticles as a super absorbent. Nucl Eng Technol 50(7):1112–1119Google Scholar
  16. 16.
    Pradhan SK, Tarafder PK (2016) A new extraction procedure for the pellet fluorimetric determination of uranium in columbite–tantalite minerals. In: Proceedings of the international seminar on ‘emerging trends in analytical chemistry (ETAC 2016)’ held on 21–23 Sept 2016 at ISEC, Nagarbhavi, BangaloreGoogle Scholar