Journal of Nondestructive Evaluation

, Volume 30, Issue 3, pp 164–171 | Cite as

A Dedicated On-Board Dual-Energy Computer Tomograph

  • Mihai Iovea
  • Marian Neagu
  • Octavian G. Duliu
  • Gheorghe Oaie
  • Stefan Szobotka
  • Gabriela Mateiasi
Article

Abstract

A dedicated on-board dual energy computer tomograph able to generate both tomographic and digital radiographic images of unconsolidated sediments cores with a diameter up to 12 cm and a height up to 1 m was built and tested on-board of the R/V Mare Nigrum. This instrument, designed to be used on-board of any oceanographic research vessel with minimum adaptations, can work very well on stationary laboratory too, provided that there is adequate protection against hard X-rays. The tomograph has a single 160 kV X-ray tube and two set of 240 in-line X-ray detectors separated by a copper attenuator (dual-energy arrangement) allowing one to obtain tomographic as well as digital radiographic images depicting the distribution of both density and effective atomic number of the objects. In tomographic and radiographic mode, the spatial resolution of reconstructed images of the linear attenuation coefficient is about 0.5 mm while in dual-energy mode, when reconstructed images depict the distribution of densities and effective atomic numbers that requires an additional smoothing filtering, the spatial resolution is about 1 mm.

By using a set of standard samples with known values of densities and effective atomic numbers we have estimated the precision in calculating the local values of these parameters to a maximum of 8%.

By its performance and by its ability to work on-board, the tomograph could be useful not only for oceanographic researches but also for any exploratory tests performed on open sea.

Keywords

Tomography Radioscopy Digital radiography Dual-energy X-ray Nondestructive testing Atomic effective number Density Sediments On-board 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Hounsfield, G.N.: Computerised transverse axial scanning tomography, Part 1: Description of system. Br. J. Radiol. 46, 1016 (1973) CrossRefGoogle Scholar
  2. 2.
    Guang-Zhong, Y., Firmin, D.N.: The birth of first CT scanner. Eng. Med. Biol. Mag. IEEE 19, 120 (2000) CrossRefGoogle Scholar
  3. 3.
    Jacobs, P., Sevens, E., Kunnen, M.: Principles of computerized X-ray tomography and applications to building materials. Sci. Total Environ. 167, 161 (1995) CrossRefGoogle Scholar
  4. 4.
    Boespflug, X., Long, B., Occhietti, S.: Cat-scan in marine stratigraphy: a quantitative approach. Mar. Geol. 122, 281 (1995) CrossRefGoogle Scholar
  5. 5.
    Ashi, J.: Computed tomography scan image analysis of sediments. In: Shipley, T.H., Ogawa, Y., Blum, P., Bahr, J.M. (eds.) Proc. Ocean Drilling Program Scientific Results, vol. 156, pp. 151–158 (1997). College Station TX Ocean Drilling Program Google Scholar
  6. 6.
    Duliu, O.G.: Computer axial tomography in geosciences: an overview. Earth-Sci. Rev. 48, 265 (1999) CrossRefGoogle Scholar
  7. 7.
    Van Geet, M., Swennen, R., Wevers, M.: Quantitative analysis of reservoir rocks by computerized tomography. Sediment. Geol. 132, 25 (2000) CrossRefGoogle Scholar
  8. 8.
    Ketcham, R.A., Carlson, W.D.: Acquisition optimization and interpretation of X-ray computed tomographic imagery: applications to the geosciences. Comput. Geosci. 27, 381 (2001) CrossRefGoogle Scholar
  9. 9.
    Flisch, A., Becker, A.: Industrial X-ray computed tomography of lake sediment drill cores. In: Mees, F., Swennen, R., Van Geet, M., Jacobs, P. (eds.) Applications of X-ray Computed Tomography in the Geosciences, vol. 215, p. 205 (2003). Geological Society London Special Publication Google Scholar
  10. 10.
    Michaud, E., Desrosiers, G., Long, B., de Montety, L., Crémer, J.-F., Pelletiera, E., Locatd, J., Gilbertb, F., Stora, G.: Use of axial tomography to follow temporal changes of benthic communities in an unstable sedimentary environment Baie des Ha! Ha! Saguenay. Fjord. J. Exp. Mar. Biol. Ecol. 265, 285–286 (2003) Google Scholar
  11. 11.
    Bouma, A.H.: Methods for the Study of Sedimentary Structures. Wiley, New York (1969) Google Scholar
  12. 12.
    Siegbahn, K.: Alpha Beta and Gamma Ray Spectroscopy. North Holland, Amsterdam (1968) Google Scholar
  13. 13.
    Rizescu, C.T., Georgescu, G.N., Duliu, O.G., Szobotka, S.A.: 3-D dual gamma-ray computer axial tomography investigation of polymetallic nodules. Deep Sea Res. I 48, 2529 (2001) CrossRefGoogle Scholar
  14. 14.
    Engler, P., Friedman, W.D.: Review of dual-energy computed tomography techniques. Mater. Eval. 48, 623 (1990) Google Scholar
  15. 15.
    Aylmore, L.A.G.: Use of computer assisted tomography in studying water movement around plant roots. Adv. Agron. 49, 1 (1993) CrossRefGoogle Scholar
  16. 16.
    Rogasik, H., Crawford, J.W., Wendroth, O., Young, I.M., Joschko, M., Ritz, K.: Discrimination of soil phases by dual energy X-ray tomography. Soil Sci. Soc. Am. J. 63, 741 (1999) CrossRefGoogle Scholar
  17. 17.
    Iovea, M., Neagu, M., Duliu, O.G., Oaie, G., Ricman, C., Mateiasi, G.: Dual-energy computer tomography and digital radiography investigation of organic and inorganic materials. In: DGZfP Proceedings BB 103-CD. Berlin, 2006 (ISBN 3-931381-86-2). http://www.ndt.net/article/ecndt2006/doc/P44.pdf (last accessed 25 May 2011)
  18. 18.
    Duliu, O.G., Rizescu, C.T., Ricman, C.: Dual energy gamma-ray axial computer tomography investigation of some metamorphic and sedimentary rocks. N Jarbuch Geol. Päleont 228, 343 (2003) Google Scholar
  19. 19.
    Freifeld, B., Kneafsky, T.J., Rack, F.R.: On-site geological core analysis using a portable X-ray computed tomography. In: Rothwell, R.G. (ed.) New Techniques in Sediment Core Analysis, vol. 267, p. 165 (2006). Geological Society London Special Publication Google Scholar
  20. 20.
    GeoEcoMar: www.geoecomar.ro (last accessed 15 May 2011)
  21. 21.
    Herman, G.T.: Correction for beam hardening in computed tomography. Phys. Med. Biol. 24, 81–106 (1979) CrossRefGoogle Scholar
  22. 22.
    Hammersberg, P., Mangard, M.: Correction for beam hardening artifacts in computerised tomography. J. X-Ray Sci. Technol. 8, 75–93 (1998) Google Scholar
  23. 23.
    Anonymous: Fundamental Norms of Radiological Safety NSR 01E. Official Bulletin of Romania 404 bis, 29th August 2000; (http://www.cncan.ro/bd/norme/nfsr-01%20engleza.pdf (in English) (last accessed 26 May 2011))

Copyright information

© Springer Science+Business Media, LLC 2011

Authors and Affiliations

  • Mihai Iovea
    • 1
  • Marian Neagu
    • 1
  • Octavian G. Duliu
    • 2
  • Gheorghe Oaie
    • 3
  • Stefan Szobotka
    • 3
  • Gabriela Mateiasi
    • 1
  1. 1.Accent Pro 2000, LtdBucharestRomania
  2. 2.Department of Atomic and Nuclear PhysicsUniversity of BucharestMagurele (Ilfov)Romania
  3. 3.National Institute of Marine Geology and GeoecologyBucharestRomania

Personalised recommendations